From 9e0603b0fadbc21b20d7eba7ef742253cc844467 Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Zbyn=C4=9Bk=20Pecina?= <58307338+peca2345@users.noreply.github.com> Date: Sat, 4 Mar 2023 19:08:45 +0100 Subject: [PATCH] Update README.md --- README.md | 1084 +++++++++++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 1054 insertions(+), 30 deletions(-) diff --git a/README.md b/README.md index b34a938..59182b4 100644 --- a/README.md +++ b/README.md @@ -33,15 +33,39 @@ In this case it is about connecting a Gree Versati III 10kw heat pump. ## ESPHome code: ``` +esphome: + name: versati-modbus-esp32 + +esp32: + board: esp32dev + framework: + type: arduino + +logger: +captive_portal: +api: + encryption: + key: "1k0OjFSddafHxtX4c5YzpeTwmWfc4X9aqgsVKzS2ntI=" + +ota: + password: "af492f27651e0694487dedbdb60e136e" + +wifi: + ssid: !secret wifi_ssid + password: !secret wifi_password + +web_server: + port: 80 + uart: id: mod_bus - tx_pin: GPIO16 # D7 for Wemos - rx_pin: GPIO17 # D6 for Wemos + tx_pin: GPIO16 + rx_pin: GPIO17 baud_rate: 9600 - stop_bits: 2 + stop_bits: 1 modbus: - flow_control_pin: GPIO23 # D5 for Wemos + flow_control_pin: GPIO23 send_wait_time: 100ms id: modbus_versati3 @@ -53,51 +77,756 @@ modbus_controller: modbus_id: modbus_versati3 setup_priority: -10 update_interval: 15s + + + +text_sensor: + - platform: template + id: versati_117_unit_status_text + name: "versati_117_unit_status" + + - platform: template + id: versati_132_thermostat_status_text + name: "versati_132_thermostat_status" + - platform: template + id: versati_135_disinfection_status_text + name: "versati_135_disinfection_status" + + + number: - platform: modbus_controller modbus_controller_id: versati3 - name: "Gree_versati_tank_temp_set" + name: "versati_2_mode_set" + id: versati_2_mode_set + address: 2 + value_type: S_WORD + entity_category: config + min_value: 1 + max_value: 5 + step: 1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_3_optional_E_heater_set" + address: 3 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 3 + mode: slider + # last: 2 + # 1:1 set/ + # 2:2 sets/ + # 3: Off + # Default: 1 set + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_4_disinfection_temp_set" + address: 4 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 40 + max_value: 70 + mode: slider + # last: 60℃ + # Default: 70℃ + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_5_floor_debug_segments_set" + address: 5 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 10 + mode: slider + # Default : 1 section + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_6_floor_debug_period_1_set" + address: 6 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 25 + max_value: 35 + mode: slider + # Default: 25℃ + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_7_delta_of_segment_temp_set" + address: 7 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 2 + max_value: 10 + mode: slider + # Default: 5℃ + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_8_segment_time_set" + address: 8 + unit_of_measurement: "h" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 12 + max_value: 72 + mode: slider + # Default: 0 Hour + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_9_WOT_cool_temp_set" + address: 9 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 7 + max_value: 25 + mode: slider + # Default: 18℃ + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_10_WOT_heat_temp_set" + address: 10 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 20 + max_value: 60 + mode: slider + # last: 46℃ + # Actual value: + # 20~60℃ [High-temp] / 20~55℃[low-temp] + # Default: + # 45℃[High-temp]/45℃[Low-temp] + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_11_RT_cool_temp_set" + address: 11 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 18 + max_value: 30 + mode: slider + # Default:24°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_12_RT_heat_temp_set" + address: 12 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 18 + max_value: 30 + mode: slider + # Default:20°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_13_tank_target_temp_set" address: 13 unit_of_measurement: "°C" value_type: S_WORD entity_category: config - -sensor: - - platform: modbus_controller - modbus_controller_id: versati3 - name: "Gree_versati_tank_temp_target" - address: 13 - unit_of_measurement: "°C" - register_type: holding - value_type: U_WORD - accuracy_decimals: 1 + step: 1 + min_value: 40 + max_value: 80 + mode: slider + # last: 48°C + # Default:50°C - platform: modbus_controller modbus_controller_id: versati3 - name: "Gree_versati_tank_temp" - address: 128 - unit_of_measurement: "°C" - register_type: holding - value_type: U_WORD - accuracy_decimals: 1 - filters: - - multiply: 0.1 - + name: "versati_14_eheater_temp_set" + address: 14 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: -20 + max_value: 18 + mode: slider + # last: -7°C + # Default:-15°C + - platform: modbus_controller modbus_controller_id: versati3 - name: "Gree_versati_outside_temp" + name: "versati_15_other_switch_on_temp_set" + address: 15 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: -20 + max_value: 18 + mode: slider + # last: -20°C + # Default:-20°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_16_HP_max_temp_set" + address: 16 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 40 + max_value: 55 + mode: slider + # last: 50°C + # Default:50°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_17_upper_AT_heat_temp_set" + address: 17 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 10 + max_value: 37 + mode: slider + # last: 12°C + # Default:25°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_18_lower_AT_heat_temp_set" + address: 18 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: -20 + max_value: 9 + mode: slider + # last: -12°C + # Default:-20°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_19_upper_RT_heat_temp_set" + address: 19 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 22 + max_value: 30 + mode: slider + # last: 24°C + # Default:24°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_20_lower_RT_heat_temp_set" + address: 20 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 18 + max_value: 21 + mode: slider + # last: 18°C + # Default:18°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_21_upper_WT_heat_temp_set" + address: 21 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 46 + max_value: 60 + mode: slider + # last: 43°C + # Actual value: 46~60℃[High-temp]/ 46~55℃[Low-temp] + # 55℃[High-temp]/55℃[Low-temp] + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_22_lower_WT_heat_temp_set" + address: 22 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 20 + max_value: 45 + mode: slider + # last: 33°C + # Default:40°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_23_upper_AT_cool_temp_set" + address: 23 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 26 + max_value: 48 + mode: slider + # last: 40°C + # Default:40°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_24_lower_AT_cool_temp_set" + address: 24 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 10 + max_value: 25 + mode: slider + # last: 25°C + # Default:25°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_25_upper_RT_cool_temp_set" + address: 25 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 24 + max_value: 30 + mode: slider + # last: 27°C + # Default:27°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_26_lower_RT_cool_temp_set" + address: 26 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 18 + max_value: 23 + mode: slider + # last: 22°C + # Default:22°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_27_upper_WT_cool_temp_set" + address: 27 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 15 + max_value: 25 + mode: slider + # last: 15°C + # Default:15°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_28_lower_WT_cool_temp_set" + address: 28 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 7 + max_value: 14 + mode: slider + # last: 7°C + # Default:7°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_29_delta_cool_temp_set" + address: 29 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 2 + max_value: 10 + mode: slider + # last: 5°C + # Default:5°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_30_delta_heat_temp_set" + address: 30 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 2 + max_value: 10 + mode: slider + # last: 10°C + # Default:10°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_31_delta_hot_water_temp_set" + address: 31 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 2 + max_value: 8 + mode: slider + # last: 5°C + # Default:5°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_32_delta_room_temp_set" + address: 32 + unit_of_measurement: "°C" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 5 + mode: slider + # last: 2°C + # Default:2°C + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_33_cool_run_time_set" + address: 33 + unit_of_measurement: "min" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 10 + mode: slider + # last: 3min + # Default:3min + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_34_heat_run_time_set" + address: 34 + unit_of_measurement: "min" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 10 + mode: slider + # last: 5min + # Default:5min + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_35_other_thermal_logic_set" + address: 35 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 3 + mode: slider + # last: 0 + # Default:1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_36_tank_heater_set" + address: 36 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 2 + mode: slider + # last: 1 + # Default:1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_37_optional_E_heater_logic_set" + address: 37 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 2 + mode: slider + # last: 2 + # Default:1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_38_current_limit_value_set" + address: 38 + unit_of_measurement: "A" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 0 + max_value: 50 + mode: slider + # last: 16A + # Default:16A + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_39_thermostat_mode_set" + address: 39 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 0 + max_value: 2 + mode: slider + # last: 2 + # 0: Without/ + # 1: Air / + # 2: Air+hot water + # Default: 0-Without + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_40_force_mode_set" + address: 40 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 3 + mode: slider + # last: 3 + # 1: Force-cool/ + # 2: Force-heat / + # 3: Off + # Default: 3 - Off + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_41_air_removal_set" + address: 41 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 1 + max_value: 3 + mode: slider + # last: 3 + # 1: Air / + # 2: Water tank/ + # 3: Off + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_42_on85_off170_set" + address: 42 + value_type: S_WORD + entity_category: config + step: 85 + min_value: 85 + max_value: 170 + mode: slider + # last: 85 + # 0xAA:On = 85 + # 0x55:Off = 170 + # Default: Off=170 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_43_power_limit_set" + address: 43 + unit_of_measurement: "kW" + value_type: S_WORD + entity_category: config + step: 1 + min_value: 0 + max_value: 10 + mode: slider + # last: 42 + # Actual value:0~10 Kw + # Default :3 Kw + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_44_error_reset_1=clear" + address: 44 + value_type: S_WORD + entity_category: config + step: 1 + min_value: 0 + max_value: 1 + # 0: Does not clear fault + # 1: Clear fault + + + + + + +sensor: + - platform: modbus_controller + modbus_controller_id: versati3 + id: versati_117_unit_status_number + name: versati_117_unit_status_number + address: 117 + register_type: holding + value_type: U_WORD + on_value: + then: + - lambda: |- + int state = id(versati_117_unit_status_number).state; + std::string text; + if (state == 1) { + text = "COOL"; + } else if (state == 2) { + text = "HEAT"; + } else if (state == 6) { + text = "HOT WATER"; + } else if (state == 8) { + text = "OFF"; + } else { + text = "UNKNOWN"; + } + id(versati_117_unit_status_text).publish_state(text); + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_118_outdoor_temp" address: 118 unit_of_measurement: "°C" register_type: holding value_type: U_WORD accuracy_decimals: 1 filters: - - multiply: 0.1 - + - multiply: 0.1 + - platform: modbus_controller modbus_controller_id: versati3 - name: "Gree_versati_water_in_temp" + name: "versati_119_discharge_temp" + address: 119 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_120_defrost_temp" + address: 120 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_121_suction_temp" + address: 121 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_122_economizer_in_temp" + address: 122 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_123_economizer_out_temp" + address: 123 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_124_discharge_pressure_temp" + address: 124 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_125_water_out_PE_temp" + address: 125 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_126_optional_water_sensor_temp" + address: 126 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_127_water_in_PE_temp" address: 127 unit_of_measurement: "°C" register_type: holding @@ -108,14 +837,309 @@ sensor: - platform: modbus_controller modbus_controller_id: versati3 - name: "Gree_versati_water_out_temp" - address: 125 + name: "versati_128_tank_control_temp" + address: 128 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_129_remote_room_temp" + address: 129 unit_of_measurement: "°C" register_type: holding value_type: U_WORD accuracy_decimals: 1 filters: - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_130_gas_pipe_temp" + address: 130 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_131_liquid_pipe_temp" + address: 131 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.1 + + - platform: modbus_controller + modbus_controller_id: versati3 + id: "versati_132_thermostat_status_number" + name: versati_132_thermostat_status_number + address: 132 + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + on_value: + then: + - lambda: |- + int state = id(versati_132_thermostat_status_number).state; + std::string text; + if (state == 1) { + text = "COOL"; + } else if (state == 2) { + text = "HEAT"; + } else if (state == 3) { + text = "OFF"; + } else { + text = "UNKNOWN"; + } + id(versati_132_thermostat_status_text).publish_state(text); + + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_133_floor_debug" + address: 133 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + filters: + - multiply: 0.001 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_134_debug_time" + address: 134 + unit_of_measurement: "h" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + + - platform: modbus_controller + modbus_controller_id: versati3 + id: "versati_135_disinfection_status_number" + name: "versati_135_disinfection_status_number" + address: 135 + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + on_value: + then: + - lambda: |- + int state = id(versati_135_disinfection_status_number).state; + std::string text; + if (state == 1) { + text = "Running"; + } else if (state == 2) { + text = "Done"; + } else if (state == 3) { + text = "Failed"; + } else if (state == 0) { + text = "OFF"; + } else { + text = "UNKNOWN"; + } + id(versati_135_disinfection_status_text).publish_state(text); + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_136_error_time_for_floor_debug" + address: 136 + unit_of_measurement: "s" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_137_weather_depend_temp" + address: 137 + unit_of_measurement: "°C" + register_type: holding + value_type: U_WORD + accuracy_decimals: 1 + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_142_setting_fruequency_status" + address: 142 + unit_of_measurement: "Hz" + register_type: holding + value_type: U_WORD + + - platform: modbus_controller + modbus_controller_id: versati3 + name: "versati_143_running_frequency_status" + address: 143 + unit_of_measurement: "Hz" + register_type: holding + value_type: U_WORD ``` +## Lovelace config: +``` +type: entities +entities: + - entity: number.versati_3_optional_e_heater_set + name: Optional E-heater + - entity: number.versati_5_floor_debug_segments_set + name: Floor debug segments + - entity: number.versati_6_floor_debug_period_1_set + name: Floor debug period 1 + - entity: number.versati_7_delta_of_segment_temp_set + name: Δ Segment + - entity: number.versati_8_segment_time_set + name: Segment time + - entity: number.versati_13_tank_target_temp_set + name: Tank target + - entity: number.versati_14_eheater_temp_set + name: E-Heater + - entity: number.versati_15_other_switch_on_temp_set + name: Other switch on + - entity: number.versati_33_cool_run_time_set + name: Cool run time + - entity: number.versati_35_other_thermal_logic_set + name: Other thermal logic segment + - entity: number.versati_36_tank_heater_set + name: Tank heater + - entity: number.versati_37_optional_e_heater_logic_set + name: Optional E-Heater logic + - entity: number.versati_40_force_mode_set + name: Force mode + - entity: number.versati_41_air_removal_set + name: Air removal + + + +type: entities +entities: + - entity: sensor.versati_118_outdoor_temp + name: Outdoor temp + - entity: sensor.versati_119_discharge_temp + name: Discharge temp + - entity: sensor.versati_120_defrost_temp + name: Defrost temp + - entity: sensor.versati_121_suction_temp + name: Suction temp + - entity: sensor.versati_122_economizer_in_temp + name: Economizer IN temp + - entity: sensor.versati_123_economizer_out_temp + name: Economizer OUT temp + - entity: sensor.versati_124_discharge_pressure_temp + name: Discharge pressure temp + - entity: sensor.versati_126_optional_water_sensor_temp + name: Optional water sensor temp + - entity: sensor.versati_128_tank_control_temp + name: Tank control temp + - entity: sensor.versati_129_remote_room_temp + name: Remote room temp + - entity: sensor.versati_131_liquid_pipe_temp + name: Liquid pipe temp + - entity: sensor.versati_132_thermostat_status_2 + name: Thermostat status + - entity: sensor.versati_132_thermostat_status_number + name: Thermostat status number + - entity: sensor.versati_133_floor_debug + name: Floor debug temp + - entity: sensor.versati_134_debug_time + name: Debug time + - entity: sensor.versati_136_error_time_for_floor_debug + name: Error time for floor debug + - entity: sensor.versati_137_weather_depend_temp + name: Weather depend temp + - entity: sensor.versati_142_setting_fruequency_status + name: Setting frequency + - entity: sensor.versati_143_running_frequency_status + name: Running frequency + + + +type: entities +entities: + - entity: number.versati_17_upper_at_heat_temp_set + name: AT upper heat + - entity: number.versati_18_lower_at_heat_temp_set + name: AT lower heat + - entity: number.versati_19_upper_rt_heat_temp_set + name: RT upper heat + - entity: number.versati_20_lower_rt_heat_temp_set + name: RT lower heat + - entity: number.versati_21_upper_wt_heat_temp_set + name: WT upper heat + - entity: number.versati_22_lower_wt_heat_temp_set + name: WT lower heat + - entity: number.versati_23_upper_at_cool_temp_set + name: AT upper cool + - entity: number.versati_24_lower_at_cool_temp_set + name: AT lower cool + - entity: number.versati_25_upper_rt_cool_temp_set + name: RT upper cool + - entity: number.versati_26_lower_rt_cool_temp_set + name: RT lower cool + - entity: number.versati_27_upper_wt_cool_temp_set + name: WT upper cool + - entity: number.versati_28_lower_wt_cool_temp_set + name: WT lower cool + - entity: number.versati_29_delta_cool_temp_set + name: Δ Cool + - entity: number.versati_30_delta_heat_temp_set + name: Δ Heat + - entity: number.versati_31_delta_hot_water_temp_set + name: Δ Hot water + - entity: number.versati_32_delta_room_temp_set + name: Δ Room + - entity: number.versati_10_wot_heat_temp_set + name: WOT heat + - entity: number.versati_9_wot_cool_temp_set + name: WOT Cool + - entity: number.versati_12_rt_heat_temp_set + name: RT heat + - entity: number.versati_11_rt_cool_temp_set + name: RT Cool + + + +type: entities +entities: + - entity: sensor.versati_135_disinfection_status_2 + name: Disinfection status + - entity: sensor.versati_117_unit_status_2 + name: Unit status + - entity: number.versati_42_on85_off170_set + name: ON (85) / OFF (170) + - entity: number.versati_39_thermostat_mode_set + name: Thermostat mode + - entity: sensor.versati_127_water_in_pe_temp + name: Water IN temp + - entity: sensor.versati_125_water_out_pe_temp + name: Water OUT PE temp + - entity: number.versati_4_disinfection_temp_set + name: Disinfection + - entity: number.versati_13_tank_target_temp_set + name: Tank target + - entity: number.versati_16_hp_max_temp_set + name: HP max + - entity: number.versati_33_cool_run_time_set + name: Cool run time + - entity: number.versati_34_heat_run_time_set + name: Heat run time + - entity: number.versati_36_tank_heater_set + name: Tank heater + - entity: number.versati_43_power_limit_set + name: Power limit + - entity: number.versati_38_current_limit_value_set + name: Current limit + - entity: number.versati_44_error_reset_1_clear + name: Error (1=clear) + +```