TMP117 Temperature Sensor
|
||
|
=========================
|
||
|
|
||
|
.. seo::
|
||
|
:description: Instructions for setting up the TMP117 Temperature sensor.
|
||
|
:image: tmp117.jpg
|
||
|
:keywords: TMP117
|
||
|
|
||
|
The TMP117 Temperature+Humidity sensor allows you to use your TMP117
|
||
|
(`datasheet <https://www.ti.com/lit/ds/symlink/tmp117.pdf>`__,
|
||
|
`sparkfun <https://www.sparkfun.com/products/15805>`__)
|
||
|
sensors with ESPHome.
|
||
|
|
||
|
.. figure:: images/tmp117.jpg
|
||
|
:align: center
|
||
|
:width: 30.0%
|
||
|
|
||
|
TMP117 Temperature Sensor.
|
||
|
(Credit: `Sparkfun <https://www.sparkfun.com/products/15805>`__, image cropped and compressed)
|
||
|
|
||
|
.. _Sparkfun: https://www.sparkfun.com/products/15805
|
||
|
|
||
|
The TMP117 is a high precision temperature sensor that communicates over I2C. Each sensor is tested on a NIST tracable test setup during Texas Instruments' production process. Accuracy should be at worst 0.1C across the -20C to +50C temperature range.
|
||
|
|
||
|
To use the sensor, first set up an :ref:`I²C Bus <i2c>` and connect the sensor to the specified pins.
|
||
|
|
||
|
If accuracy is a must, see section 8.2.2.2 of the `datasheet <https://www.ti.com/lit/ds/symlink/tmp117.pdf>`__.
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
# Example configuration entry
|
||
|
sensor:
|
||
|
- platform: tmp117
|
||
|
name: "Living Room Temperature"
|
||
|
update_interval: 60s
|
||
|
|
||
|
Configuration variables
|
||
|
-----------------------
|
||
|
|
||
|
- **name** (**Required**, string): The name for the temperature sensor.
|
||
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for lambdas/multiple sensors.
|
||
|
- **address** (*Optional*, int): The I²C address of the sensor.
|
||
|
See :ref:`I²C Addresses <tmp117_i2c_addresses>` for more information.
|
||
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. The sensor component sets the maximum possible averaging in the sensor based on this.
|
||
|
|
||
|
.. _tmp117_i2c_addresses:
|
||
|
|
||
|
I²C Addresses
|
||
|
-------------
|
||
|
|
||
|
In order to allow multiple sensors to be connected to the same I²C bus,
|
||
|
the creators of this sensor hardware have included some options to
|
||
|
change the i²c address.
|
||
|
|
||
|
- If the address pin is pulled to GND, the address is ``0x48`` (Default).
|
||
|
- If the address pin is pulled to VCC, the address is ``0x49``.
|
||
|
- If the address pin is tied to SDA, the address is ``0x4A``.
|
||
|
- If the address pin is tied to SCL, the address is ``0x4B``.
|