QMP6988 Temperature+Pressure Sensor
===================================
.. seo::
:description: Instructions for setting up QMP6988 temperature and pressure sensors with ESPHome
:keywords: QMP6988
The ``qmp6988`` sensor platform allows you to use your QMP6988
(`datasheet <https://m5stack.oss-cn-shenzhen.aliyuncs.com/resource/docs/datasheet/unit/enviii/QMP6988%20Datasheet.pdf>`__,
`M5Stack`_) temperature and pressure sensors with ESPHome. The :ref:`I²C <i2c>` is
required to be set up in your configuration for this sensor to work.
.. figure:: ../../images/qmp6988_env3.png
:align: center
:width: 40.0%
QMP6988 Temperature and Pressure Sensor.
.. _M5Stack: https://docs.m5stack.com/en/unit/envIII
.. code-block:: yaml
# Example configuration entry
sensor:
- platform: qmp6988
temperature:
name: "Living Room Temperature"
oversampling: 16x
pressure:
name: "Living Room Pressure"
oversampling: 16x
address: 0x70
update_interval: 60s
iir_filter: 2x
Configuration variables:
------------------------
- **temperature** (*Optional*): The information for the temperature sensor
- **oversampling** (*Optional*): The oversampling parameter for the temperature sensor.
See :ref:`Oversampling Options <qmp6988-oversampling>`.
- All other options from :ref:`Sensor <config-sensor>`.
- **pressure** (*Optional*): The information for the pressure sensor.
- **oversampling** (*Optional*): The oversampling parameter for the temperature sensor.
See :ref:`Oversampling Options <qmp6988-oversampling>`.
- All other options from :ref:`Sensor <config-sensor>`.
- **address** (*Optional*, int): Manually specify the I²C address of
the sensor. Defaults to ``0x70``. ``0x56`` is also configurable - see datasheet.
- **iir_filter** (*Optional*): Set up an Infinite Impulse Response filter to increase accuracy. One of
``OFF``, ``2x``, ``4x``, ``8x``, ``16x``, ``32x``. Defaults to ``OFF``.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
.. _qmp6988-oversampling:
Oversampling Options
--------------------
By default, the QMP6988 sensor has been configured to measure each value 8 times when requesting a new value. You can, however,
configure this amount. Possible oversampling values:
- ``NONE`` (value is skipped)
- ``1x``
- ``2x``
- ``4x``
- ``8x`` (default)
- ``16x``
- ``32x``
- ``64x``
2022-03-14 20:09:29 +01:00
See Also
--------
- :ref:`sensor-filters`
- :apiref:`qmp6988/qmp6988.h`
- `QMP6988 Library <https://github.com/m5stack/UNIT_ENV>`__ by `M5Stack <https://m5stack.com>`__