CSE7761 Power Sensor
====================
.. seo::
:description: Instructions for setting up CSE7761 power sensors for the Sonoff Dual R3 v1.x
:image: cse7761.png
:keywords: cse7761, Sonoff Dual R3
The ``cse7761`` sensor platform allows you to use your CSE7761 voltage/current and power sensors
with ESPHome. This sensor is commonly found in Sonoff Dual R3 v1.x.
.. note::
SAFETY HAZARD: Some devices such as Sonoff POWs/Shelly/etc, have the digital GND connected directly to mains voltage so **the GPIOs become LIVE during normal operation**. Our advice is to mark these boards to prevent any use of the dangerous digital pins.
As the communication with the CSE7761 done using UART, you need
to have an :ref:`UART bus <uart>` in your configuration with the ``tx_pin`` and ``rx_pin`` connected to the CSE7761.
Additionally, you need to set the baud rate to 38400 and parity to ``EVEN``.
.. code-block:: yaml
# Example configuration entry
# Disable logging over serial
logger:
baud_rate: 0
uart:
tx_pin: GPIO25
rx_pin: GPIO26
baud_rate: 38400
parity: EVEN
sensor:
- platform: cse7761
voltage:
name: 'CSE7761 Voltage'
current_1:
name: 'CSE7761 Current 1'
current_2:
name: 'CSE7761 Current 2'
active_power_1:
name: 'CSE7761 Active Power 1'
active_power_2:
name: 'CSE7761 Active Power 2'
update_interval: 5s
.. note::
The configuration above should work for Sonoff Dual R3 v1.x.
Configuration variables:
------------------------
- **voltage** (*Optional*): Use the voltage value of the sensor in V (RMS).
All options from :ref:`Sensor <config-sensor>`.
- **current_1** (*Optional*): Use the current value of the channel 1 in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **current_2** (*Optional*): Use the current value of the channel 2 in amperes. All options from
:ref:`Sensor <config-sensor>`.
- **active_power_1** (*Optional*): Use the (active) power value of the channel 1 in watts. All options from
:ref:`Sensor <config-sensor>`.
- **active_power_2** (*Optional*): Use the (active) power value of the channel 2 in watts. All options from
:ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
- **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`UART Component <uart>` if you want