esphome-docs/components/climate/tuya.rst

73 lines
3.0 KiB
ReStructuredText
Raw Normal View History

Tuya Climate
============
.. seo::
:description: Instructions for setting up a Tuya climate device.
:image: air-conditioner.png
The ``tuya`` climate platform creates a climate device from a tuya component.
The Tuya fan requires a :doc:`/components/tuya` to be configured.
.. code-block:: text
[22:03:11][C][tuya:023]: Tuya:
[22:03:11][C][tuya:032]: Datapoint 1: switch (value: ON)
[22:03:11][C][tuya:032]: Datapoint 2: switch (value: OFF)
[22:03:11][C][tuya:034]: Datapoint 3: int value (value: 20)
[22:03:11][C][tuya:034]: Datapoint 4: int value (value: 19)
[22:03:11][C][tuya:034]: Datapoint 5: int value (value: 0)
[22:03:11][C][tuya:036]: Datapoint 7: enum (value: 1)
[22:03:11][C][tuya:046]: Product: '{"p":"ynjanlglr4qa6dxf","v":"1.0.0","m":0}'
On this controller, the data points are:
- 1 represents the climate on/off state.
- 2 represents the child lock switch. (use the :doc:`/components/switch/tuya` component to control this)
- 3 represents the target temperature.
- 4 represents the current temperature.
- 5 represents the timer but is not yet available to be used in ESPHome.
- 7 represents the eco mode switch. (use the :doc:`/components/switch/tuya` component to control this)
Based on this, you can create the climate device as follows:
.. code-block:: yaml
climate:
- platform: tuya
name: "My Climate Device"
switch_datapoint: 1
target_temperature_datapoint: 3
current_temperature_datapoint: 4
Configuration variables:
------------------------
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
- **name** (**Required**, string): The name of the climate device.
- **switch_datapoint** (**Required**, int): The datapoint id number of the climate switch.
- **target_temperature_datapoint** (**Required**, int): The datapoint id number of the target temperature.
- **current_temperature_datapoint** (**Required**, int): The datapoint id number of the current temperature.
2021-02-07 17:35:39 +01:00
- **temperature_multiplier** (*Optional*, float): A multiplier to modify the incoming and outgoing temperature values - :ref:`see below <temperature-multiplier>`.
If the device has different multipliers for current and target temperatures, **temperature_multiplier** can be replaced with both of:
2021-02-07 17:35:39 +01:00
- **current_temperature_multiplier** (*Optional*, float): A multiplier to modify the current temperature value.
- **target_temperature_multiplier** (*Optional*, float): A multiplier to modify the target temperature value.
- All other options from :ref:`Climate <config-climate>`.
.. _temperature-multiplier:
Temperature multiplier
----------------------
Some Tuya climate devices report the temperature with a multiplied factor. This is because the MCU only utlizes
integers for data reporting and to get a .5 temperature you need to divide by 2 on the ESPHome side.
See Also
--------
- :doc:`/components/tuya`
- :doc:`/components/climate/index`
- :apiref:`tuya/climate/tuya_climate.h`
- :ghedit:`Edit`