PVVX MiThermometer Display
|
||
|
==========================
|
||
|
|
||
|
.. seo::
|
||
|
:description: Instructions for setting up BLE devices with PVVX MiThermometer custom firmware as displays.
|
||
|
:image: /components/sensor/images/xiaomi_lywsd03mmc.jpg
|
||
|
|
||
|
The ``pvvx_mithermometer`` display platform allows you to use devices running the `ATC_MiThermometer firmware <https://github.com/pvvx/ATC_MiThermometer>`__ by pvvx as display drivers with ESPHome.
|
||
|
|
||
|
.. figure:: /components/sensor/images/xiaomi_lywsd03mmc.jpg
|
||
|
:align: center
|
||
|
:width: 75.0%
|
||
|
|
||
|
Xiaomi LYWSD03MMC.
|
||
|
|
||
|
The data to be displayed is transmitted as external data via BLE.
|
||
|
To do this, a ``ble_client`` component must be set up.
|
||
|
This component can also synchronize the time of the pvvx device by transmitting a timestamp on each connection.
|
||
|
After the data has been transmitted, the BLE connection is terminated in order to be able to receive the advertising data required for the ``pvvx_mithermometer`` sensor platform.
|
||
|
|
||
|
The pvvx firmware refreshes the screen periodically (can be set as minimum LCD refresh rate in the firmware configuration).
|
||
|
By default, the internal sensor data and, if available and valid (``validity_period``), the external data are switched every 2.5 s.
|
||
|
Further firmware configuration makes it possible to activate other display modes such as time and battery status.
|
||
|
The firmware configuration can be changed via browser using `TelinkMiFlasher.html <https://pvvx.github.io/ATC_MiThermometer/TelinkMiFlasher.html>`__.
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
# Example configuration entry
|
||
|
esp32_ble_tracker:
|
||
|
|
||
|
ble_client:
|
||
|
- mac_address: "A4:C1:38:B1:CD:7F"
|
||
|
id: pvvx_ble_display
|
||
|
|
||
|
display:
|
||
|
- platform: pvvx_mithermometer
|
||
|
ble_client_id: pvvx_ble_display
|
||
|
lambda: |-
|
||
|
it.print_bignum(23.1);
|
||
|
it.print_unit(pvvx_mithermometer::UNIT_DEG_C);
|
||
|
it.print_smallnum(33);
|
||
|
it.print_percent(true);
|
||
|
it.print_happy(true);
|
||
|
it.print_bracket(true);
|
||
|
|
||
|
|
||
|
Configuration variables:
|
||
|
------------------------
|
||
|
|
||
|
- **ble_client_id** (**Required**, :ref:`config-id`): ID of the associated BLE client.
|
||
|
- **time_id** (*Optional*, :ref:`config-id`): ID of a :doc:`/components/time` component. If set, the time will be synchronized with every connection.
|
||
|
- **disconnect_delay** (*Optional*, :ref:`config-time`): The amount of time the BLE connection is maintained before being disconnected again. Defaults to ``5s``.
|
||
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to transmit the display data. Defaults to ``60s``.
|
||
|
- **validity_period** (*Optional*, :ref:`config-time`): The time periode for which the pvvx device should display the information. Defaults to ``5min``.
|
||
|
- **lambda** (*Optional*, :ref:`lambda <config-lambda>`): The lambda to use to define the information to be displayed.
|
||
|
See :ref:`display-pvvx_mithermometer_lambda` for more information.
|
||
|
- **auto_clear_enabled** (*Optional*, boolean): Whether to automatically clear the display data before each lambda call,
|
||
|
or to keep the existing display content (must overwrite explicitly, e.g., only on data change). Defaults to ``true``.
|
||
|
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
||
|
|
||
|
.. _display-pvvx_mithermometer_lambda:
|
||
|
|
||
|
Rendering Lambda
|
||
|
----------------
|
||
|
|
||
|
The ``pvvx_mithermometer`` displays can only show two numbers with optional units and a smiley face. Therefore, the API is tailord to these limitations.
|
||
|
In the lambda you're passed a variable called ``it`` as with all other displays. In this case however, ``it`` is a ``PVVXDisplay`` instance (see API Reference).
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
display:
|
||
|
- platform: pvvx_mithermometer
|
||
|
# ...
|
||
|
lambda: |-
|
||
|
// Print -2.1 as big number (first row)
|
||
|
it.print_bignum(-2.1);
|
||
|
// Print °C next to the big number
|
||
|
it.print_unit(pvvx_mithermometer::UNIT_DEG_C);
|
||
|
// Print 88 as small number (second row)
|
||
|
it.print_smallnum(88);
|
||
|
// Print % next to the small number
|
||
|
it.print_percent(true);
|
||
|
// Print the low battery symbol
|
||
|
it.print_battery(true);
|
||
|
|
||
|
// Print a happy smiley. Results in " ^_^ "
|
||
|
it.print_happy(true);
|
||
|
// Print a sad smiley. Results in " -∧- "
|
||
|
it.print_sad(true);
|
||
|
// The comination of happy and sad simley results in " Δ△Δ "
|
||
|
|
||
|
// Print round brackets around the simley
|
||
|
it.print_bracket(true);
|
||
|
// The final result is "(Δ△Δ)"
|
||
|
|
||
|
|
||
|
Valid values for the big number (``it.print_bignum()``) are from -99.5 to 1999.5. Smaller values are displayed as ``Lo``, larger ones as ``Hi``. It will be printed to the screen. If not defined, a 0 will be displayed.
|
||
|
|
||
|
Valid values for the small number (``it.print_smallnum()``) are from -9 to 99. Smaller values are displayed as ``Lo``, larger ones as ``Hi``. If not defined, a 0 will be displayed.
|
||
|
|
||
|
Possible values for the unit of the big number (``it.print_unit()``) are:
|
||
|
|
||
|
- ``pvvx_mithermometer::UNIT_NONE``: do not show a unit
|
||
|
- ``pvvx_mithermometer::UNIT_DEG_GHE``: show ``°Г``
|
||
|
- ``pvvx_mithermometer::UNIT_MINUS``: show ``-``
|
||
|
- ``pvvx_mithermometer::UNIT_DEG_F``: show ``°F``
|
||
|
- ``pvvx_mithermometer::UNIT_LOWDASH``: show ``_``
|
||
|
- ``pvvx_mithermometer::UNIT_DEG_C``: show ``°C``
|
||
|
- ``pvvx_mithermometer::UNIT_LINES``: show ``=``
|
||
|
- ``pvvx_mithermometer::UNIT_DEG_E``: show ``°E``
|
||
|
|
||
|
The appearance of the smiley can be defined by combining the functions ``it.print_happy()``, ``it.print_sad()`` and ``it.print_bracket(true)``:
|
||
|
|
||
|
=================== =============== ================= ==========
|
||
|
``print_bracket()`` ``print_sad()`` ``print_happy()`` result
|
||
|
=================== =============== ================= ==========
|
||
|
false false false
|
||
|
false false true ``^_^``
|
||
|
false true false ``-∧-``
|
||
|
false true true ``Δ△Δ``
|
||
|
true false false ``( )``
|
||
|
true false true ``(^_^)``
|
||
|
true true false ``(-∧-)``
|
||
|
true true true ``(Δ△Δ)``
|
||
|
=================== =============== ================= ==========
|
||
|
|
||
|
|
||
|
Display states of other sensors
|
||
|
*******************************
|
||
|
|
||
|
The following example display the sensor states of a MiFlora sensor on a pvvx display. The time is also synchronized.
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
time:
|
||
|
- platform: homeassistant
|
||
|
id: homeassistant_time
|
||
|
|
||
|
esp32_ble_tracker:
|
||
|
|
||
|
ble_client:
|
||
|
- mac_address: "A4:C1:38:B1:CD:7F"
|
||
|
id: pvvx_ble_display
|
||
|
|
||
|
sensor:
|
||
|
- platform: pvvx_mithermometer
|
||
|
mac_address: "A4:C1:38:B1:CD:7F"
|
||
|
temperature:
|
||
|
name: "PVVX Temperature"
|
||
|
humidity:
|
||
|
name: "PVVX Humidity"
|
||
|
battery_level:
|
||
|
name: "PVVX Battery-Level"
|
||
|
battery_voltage:
|
||
|
name: "PVVX Battery-Voltage"
|
||
|
- platform: xiaomi_hhccjcy01
|
||
|
mac_address: '94:2B:FF:5C:91:61'
|
||
|
temperature:
|
||
|
name: "Xiaomi HHCCJCY01 Temperature"
|
||
|
id: miflora_temperature
|
||
|
moisture:
|
||
|
name: "Xiaomi HHCCJCY01 Moisture"
|
||
|
id: miflora_moisture
|
||
|
illuminance:
|
||
|
name: "Xiaomi HHCCJCY01 Illuminance"
|
||
|
conductivity:
|
||
|
name: "Xiaomi HHCCJCY01 Soil Conductivity"
|
||
|
|
||
|
display:
|
||
|
- platform: pvvx_mithermometer
|
||
|
ble_client_id: pvvx_ble_display
|
||
|
update_interval: 10min
|
||
|
validity_period: 15min
|
||
|
time_id: homeassistant_time
|
||
|
lambda: |-
|
||
|
double temp = id(miflora_temperature).state;
|
||
|
double moisture = id(miflora_moisture).state;
|
||
|
it.print_bignum(temp);
|
||
|
it.print_unit(pvvx_mithermometer::UNIT_DEG_C);
|
||
|
it.print_smallnum(moisture);
|
||
|
it.print_percent();
|
||
|
if (temp < 5 || temp > 30 || moisture < 10 || moisture > 50) {
|
||
|
it.print_sad();
|
||
|
} else {
|
||
|
it.print_happy();
|
||
|
}
|
||
|
|
||
|
Only synchronize the time once a day
|
||
|
************************************
|
||
|
|
||
|
The following example will synchronized the time of the pvvx device once a day.
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
time:
|
||
|
- platform: homeassistant
|
||
|
id: homeassistant_time
|
||
|
|
||
|
esp32_ble_tracker:
|
||
|
|
||
|
ble_client:
|
||
|
- mac_address: "A4:C1:38:B1:CD:7F"
|
||
|
id: pvvx_ble_display
|
||
|
|
||
|
sensor:
|
||
|
- platform: pvvx_mithermometer
|
||
|
mac_address: "A4:C1:38:B1:CD:7F"
|
||
|
temperature:
|
||
|
name: "PVVX Temperature"
|
||
|
humidity:
|
||
|
name: "PVVX Humidity"
|
||
|
battery_level:
|
||
|
name: "PVVX Battery-Level"
|
||
|
battery_voltage:
|
||
|
name: "PVVX Battery-Voltage"
|
||
|
|
||
|
display:
|
||
|
- platform: pvvx_mithermometer
|
||
|
ble_client_id: pvvx_ble_display
|
||
|
update_interval: 24h
|
||
|
validity_period: 0s
|
||
|
time_id: homeassistant_time
|
||
|
|
||
|
|
||
|
|
||
|
See Also
|
||
|
--------
|
||
|
|
||
|
- :doc:`index`
|
||
|
- :doc:`/components/ble_client`
|
||
|
- :doc:`/components/sensor/xiaomi_ble`
|
||
|
- :apiref:`pvvx_mithermometer/display/pvvx_display.h`
|
||
|
- `ATC_MiThermometer firmware <https://github.com/pvvx/ATC_MiThermometer>`__ by `pvvx <https://github.com/pvvx>`__
|
||
|
- :ghedit:`Edit`
|