esphome-docs/esphomeyaml/components/output/index.rst

106 lines
2.6 KiB
ReStructuredText
Raw Normal View History

.. _output:
2018-05-13 11:37:02 +02:00
Output Component
================
Each platform of the ``output`` domain exposes some output to
esphomelib. These are grouped into two categories: ``binary`` outputs
(that can only be ON/OFF) and ``float`` outputs (like PWM, can output
any rational value between 0 and 1).
2018-06-01 18:10:00 +02:00
.. _config-output:
2018-05-13 11:37:02 +02:00
Base Output Configuration
2018-10-12 16:33:22 +02:00
-------------------------
2018-05-13 11:37:02 +02:00
Each output platform extends this configuration schema.
.. code:: yaml
# Example configuration entry
output:
- platform: ...
id: myoutput_id
power_supply: power_supply_id
inverted: False
max_power: 0.75
Configuration variables:
2018-06-01 18:10:00 +02:00
- **id** (**Required**, :ref:`config-id`): The id to use for this output component.
- **power_supply** (*Optional*, :ref:`config-id`): The :doc:`power
supply </esphomeyaml/components/power_supply>` to connect to
this output. When the output is enabled, the power supply will
automatically be switched on too.
- **inverted** (*Optional*, boolean): If the output should be treated
as inverted. Defaults to ``False``.
- **max_power** (*Optional*, float): Only for float outputs. Sets the
maximum output value of this output platform. Each value will be
multiplied by this. Must be in range from 0 to 1. Defaults to 1.
.. _output-turn_on_action:
``output.turn_on`` Action
2018-10-12 16:33:22 +02:00
*************************
This action turns the output with the given ID on when executed.
.. code:: yaml
on_...:
then:
- output.turn_on: relay_1
.. _output-turn_off_action:
``output.turn_off`` Action
2018-10-12 16:33:22 +02:00
**************************
This action turns the output with the given ID off when executed.
.. code:: yaml
on_...:
then:
- output.turn_off: relay_1
.. _output-set_level_action:
``output.set_level`` Action
2018-10-12 16:33:22 +02:00
***************************
This action sets the float output to the given level when executed. Note: This only
works with floating point outputs like ESP8266 PWM or LEDC.
.. code:: yaml
on_...:
then:
- output.set_level:
id: output_1
level: 50%
2018-06-01 18:10:00 +02:00
Full Output Index
2018-10-12 16:33:22 +02:00
-----------------
2018-06-01 18:10:00 +02:00
- :doc:`/esphomeyaml/components/switch/output`
- :doc:`/esphomeyaml/components/power_supply`
- :doc:`/esphomeyaml/components/light/binary`
- :doc:`/esphomeyaml/components/light/monochromatic`
- :doc:`/esphomeyaml/components/light/rgb`
- :doc:`/esphomeyaml/components/fan/binary`
- :doc:`/esphomeyaml/components/fan/speed`
2018-06-03 12:50:44 +02:00
- :doc:`API Reference </api/output/index>`
2018-06-04 08:17:22 +02:00
- `Edit this page on GitHub <https://github.com/OttoWinter/esphomedocs/blob/current/esphomeyaml/components/output/index.rst>`__
2018-06-01 18:10:00 +02:00
.. toctree::
:maxdepth: 1
esp8266_pwm.rst
gpio.rst
ledc.rst
pca9685.rst
2018-10-12 16:33:22 +02:00
.. disqus::