2020-12-21 20:27:24 +01:00
|
|
|
|
.. _canbus:
|
|
|
|
|
|
|
|
|
|
CAN bus
|
|
|
|
|
=======
|
|
|
|
|
|
|
|
|
|
.. seo::
|
|
|
|
|
:description: Instructions for setting up an CAN bus in ESPHome
|
|
|
|
|
:image: canbus.png
|
|
|
|
|
:keywords: CAN
|
|
|
|
|
|
|
|
|
|
Controller Area Network (CAN bus) is a serial bus protocol to connect individual systems and sensors
|
|
|
|
|
as an alternative to conventional multi-wire looms.
|
|
|
|
|
It allows automotive components to communicate on a single or dual-wire networked data bus up to 1Mbps.
|
|
|
|
|
CAN is an International Standardization Organization (ISO) defined serial communications bus originally
|
|
|
|
|
developed for the automotive industry to replace the complex wiring harness with a two-wire bus. The
|
|
|
|
|
specification calls for high immunity to electrical interference and the ability to self-diagnose and repair
|
|
|
|
|
data errors. These features have led to CAN’s popularity in a variety of industries including building
|
|
|
|
|
automation, medical, and manufacturing.
|
|
|
|
|
|
|
|
|
|
The current ESPHome implementation supports single frame data transfer. In this way you may send and
|
|
|
|
|
receive data frames up to 8 bytes.
|
|
|
|
|
With this you can transmit the press of a button or the feedback from a sensor on the bus.
|
|
|
|
|
All other devices on the bus will be able to get this data to switch on/off a light or display the
|
|
|
|
|
transmitted data.
|
|
|
|
|
|
|
|
|
|
The CAN bus itself has only two wires named Can High and Can Low or CanH and CanL. For the ESPHome
|
|
|
|
|
CAN bus to work you need to select the device that has the physical CAN bus implemented.
|
2021-10-15 21:11:19 +02:00
|
|
|
|
At this moment only the MCP2515 controller is supported. You can configure multiple buses.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
Any can bus node can transmit data at any time, and any node can send any ``can_id`` value and any
|
|
|
|
|
node can receive any can_id too. Is up to you how to organize the can_id values. You can setup a can
|
|
|
|
|
bus network where each node has a can id which will use to broadcast data about itself, if a node
|
|
|
|
|
should, e.g. turn on a light, it can listen for can messages with the can id assigned to it.
|
|
|
|
|
So you can have several nodes being able to control a light in e.g. node 20.
|
|
|
|
|
|
|
|
|
|
Base CAN Bus Configuration
|
|
|
|
|
--------------------------
|
|
|
|
|
|
|
|
|
|
Each canbus platform extends this configuration schema.
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
# Example configuration entry
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: ...
|
|
|
|
|
can_id: 4
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: 500
|
2021-07-28 23:56:11 +02:00
|
|
|
|
use_extended_id: false
|
2020-12-21 20:27:24 +01:00
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
std::string b(x.begin(), x.end());
|
|
|
|
|
ESP_LOGD("can id 500", "%s", &b[0] );
|
|
|
|
|
|
|
|
|
|
Configuration variables:
|
|
|
|
|
|
|
|
|
|
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
|
|
|
|
- **can_id** (**Required**, integer): default *can id* used for transmitting frames.
|
2021-07-28 23:56:11 +02:00
|
|
|
|
- **use_extended_id** (*Optional*, boolean): default *false* identifies the type of *can_id*:
|
|
|
|
|
*false*: Standard 11 bits IDs, *true*: Extended 29 bits ID
|
2021-02-20 22:02:46 +01:00
|
|
|
|
- **bit_rate** (*Optional*, enum): One of the supported bitrates. Defaults to ``125KBPS``.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
- 5KBPS
|
|
|
|
|
- 10KBPS
|
|
|
|
|
- 20KBPS
|
|
|
|
|
- 31K25BPS
|
|
|
|
|
- 33KBPS
|
|
|
|
|
- 40KBPS
|
|
|
|
|
- 50KBPS
|
|
|
|
|
- 80KBPS
|
|
|
|
|
- 83K3BPS
|
|
|
|
|
- 95KBPS
|
|
|
|
|
- 100KBPS
|
|
|
|
|
- 125KBPS
|
|
|
|
|
- 200KBPS
|
|
|
|
|
- 250KBPS
|
|
|
|
|
- 500KBPS
|
|
|
|
|
- 1000KBPS
|
|
|
|
|
|
|
|
|
|
Automations:
|
|
|
|
|
|
|
|
|
|
- **on_frame** (*Optional*, :ref:`Automation <automation>`): An automation to perform when ability
|
2021-02-20 22:02:46 +01:00
|
|
|
|
CAN Frame is received. See :ref:`canbus-on-frame`.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
.. _canbus-on-frame:
|
|
|
|
|
|
|
|
|
|
``on_frame``
|
|
|
|
|
************
|
|
|
|
|
|
|
|
|
|
This automation will be triggered when a can frame is received. A variable ``x`` of type
|
|
|
|
|
``std::vector<uint8_t>`` is passed to the automation for use in lambdas.
|
|
|
|
|
|
|
|
|
|
.. note::
|
|
|
|
|
|
2021-05-03 13:10:47 +02:00
|
|
|
|
Messages this node sends to the same ID will not show up as received messages.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: ...
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: 43 # the received can_id
|
|
|
|
|
then:
|
|
|
|
|
- if:
|
|
|
|
|
condition:
|
|
|
|
|
lambda: 'return (x.size() > 0) ? x[0] == 0x11 : false;'
|
|
|
|
|
then:
|
|
|
|
|
light.toggle: light1
|
|
|
|
|
|
2021-02-20 22:02:46 +01:00
|
|
|
|
``canbus.send`` Action
|
|
|
|
|
**********************
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
The can bus can transmit frames by means of the ``canbus.send`` action.
|
|
|
|
|
There are several forms to use it:
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
on_...:
|
|
|
|
|
- canbus.send:
|
|
|
|
|
data: [ 0x10, 0x20, 0x30 ]
|
|
|
|
|
canbus_id: my_mcp2515 # optional if you only have 1 canbus device
|
|
|
|
|
can_id: 23 # override the can_id configured in the can bus
|
|
|
|
|
|
|
|
|
|
on_...:
|
|
|
|
|
- canbus.send: [ 0x11, 0x22, 0x33 ]
|
|
|
|
|
|
|
|
|
|
- canbus.send: 'hello'
|
|
|
|
|
|
|
|
|
|
# Templated, return type is std::vector<uint8_t>
|
|
|
|
|
- canbus.send: !lambda
|
|
|
|
|
return {0x00, 0x20, 0x42};
|
|
|
|
|
|
|
|
|
|
Configuration variables:
|
|
|
|
|
|
2021-02-07 17:35:39 +01:00
|
|
|
|
- **data** (**Required**, binary data): Data to transmit, up to 8 bytes or
|
2020-12-21 20:27:24 +01:00
|
|
|
|
characters are supported by can bus per frame.
|
|
|
|
|
- **canbus_id** (*Optional*): Optionally set the can bus id to use for transmitting
|
|
|
|
|
the frame. Not needed if you are using only 1 can bus.
|
|
|
|
|
- **can_id** (*Optional*, int): Allows to override the can id configured in
|
|
|
|
|
the can bus device.
|
2021-07-28 23:56:11 +02:00
|
|
|
|
- **use_extended_id** (*Optional*, boolean): default *false* identifies the type of *can_id*:
|
|
|
|
|
*false*: Standard 11 Bit IDs, *true*: Extended 29Bit ID
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
2021-02-20 22:02:46 +01:00
|
|
|
|
MCP2515 Component
|
|
|
|
|
-----------------
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
2021-05-03 13:10:47 +02:00
|
|
|
|
The MCP2515 is a spi device and therefore you must first add the configuration for the spi bus to your file.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
You need to have an :ref:`SPI bus <spi>` in your configuration with both the **mosi_pin** and **miso_pin** set.
|
|
|
|
|
|
2021-05-03 13:10:47 +02:00
|
|
|
|
For wiring up the MSP2515 please refer to the section below.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
2021-02-20 22:02:46 +01:00
|
|
|
|
Configuration variables:
|
|
|
|
|
************************
|
|
|
|
|
|
2020-12-21 20:27:24 +01:00
|
|
|
|
- **cs_pin** (**Required**, :ref:`Pin Schema <config-pin_schema>`): Is used to tell the receiving SPI device
|
|
|
|
|
when it should listen for data on the SPI bus. Each device has an individual ``CS`` line.
|
|
|
|
|
Sometimes also called ``SS``.
|
|
|
|
|
- **clock** (*Optional*): One of ``8MHZ``, ``16MHZ`` or ``20MHZ``. Clock crystal used on the MCP2515 device.
|
|
|
|
|
Defaults to ``8MHZ``.
|
2021-05-03 13:10:47 +02:00
|
|
|
|
- **mode** (*Optional*): Operation mode. Default to ``NORMAL``
|
2020-12-21 20:27:24 +01:00
|
|
|
|
|
|
|
|
|
- NORMAL: Normal operation
|
|
|
|
|
- LOOPBACK: Loopback mode can be used to just test you spi connections to the device
|
|
|
|
|
- LISTENONLY: only receive data
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
# Example configuration entry
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: mcp2515
|
|
|
|
|
cs_pin: D5
|
|
|
|
|
can_id: 4
|
|
|
|
|
bit_rate: 50kbps
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: 500
|
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
std::string b(x.begin(), x.end());
|
|
|
|
|
ESP_LOGD("canid 500", "%s", &b[0] );
|
|
|
|
|
- light.turn_off: light_1
|
|
|
|
|
- can_id: 501
|
|
|
|
|
then:
|
|
|
|
|
- light.turn_on:
|
|
|
|
|
id: light_1
|
|
|
|
|
brightness: !lambda "return (x.size() > 0) ? (float) x[0]/255 : 0;"
|
|
|
|
|
|
|
|
|
|
Wiring options
|
|
|
|
|
---------------
|
|
|
|
|
Easiest approach is to just use fully assembled boards and just add one resistor in the MISO line.
|
|
|
|
|
This runs MOSI, SCK and CS out of specification which is nearly never a problem.
|
|
|
|
|
|
|
|
|
|
.. figure:: images/canbus_mcp2515_resistor.png
|
|
|
|
|
:align: center
|
|
|
|
|
:target: ../_images/canbus_mcp2515_resistor.png
|
|
|
|
|
|
|
|
|
|
A more advanced option is to fully convert the 5V and 3.3V logic levels with a level shifter.
|
|
|
|
|
|
|
|
|
|
.. figure:: images/canbus_mcp2515_txs0108e.png
|
|
|
|
|
:align: center
|
|
|
|
|
:target: ../_images/canbus_mcp2515_txs0108e.png
|
|
|
|
|
|
|
|
|
|
Extended ID
|
|
|
|
|
-----------
|
|
|
|
|
Standard IDs and Extended IDs can coexist on the same segment.
|
|
|
|
|
|
|
|
|
|
.. note::
|
|
|
|
|
|
2021-05-03 13:10:47 +02:00
|
|
|
|
It is important to know that for example Standard 0x123 and Extended 0x123 are different addresses.
|
2020-12-21 20:27:24 +01:00
|
|
|
|
This example shows how the different ID types are used in the configuration for transmission and receiving.
|
|
|
|
|
For the IDs decimal or hexadecimal notation is possible:
|
|
|
|
|
0x000 - 0x7ff / 0-2047 for Standard IDs only.
|
|
|
|
|
0x00000000 - 0x1fffffff / 0-536870911 for Extended IDs.
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
# Transmission of extended and standard ID 0x100 every second
|
|
|
|
|
time:
|
|
|
|
|
- platform: sntp
|
|
|
|
|
on_time:
|
|
|
|
|
- seconds: /1
|
|
|
|
|
then:
|
|
|
|
|
- canbus.send:
|
2021-02-07 17:35:39 +01:00
|
|
|
|
# Extended ID explicit
|
2021-07-28 23:56:11 +02:00
|
|
|
|
use_extended_id: true
|
2020-12-21 20:27:24 +01:00
|
|
|
|
can_id: 0x100
|
|
|
|
|
data: [0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08]
|
|
|
|
|
- canbus.send:
|
|
|
|
|
# Standard ID by default
|
|
|
|
|
can_id: 0y100
|
|
|
|
|
data: [0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08]
|
|
|
|
|
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: mcp2515
|
|
|
|
|
id: my_mcp2515
|
|
|
|
|
spi_id: McpSpi
|
|
|
|
|
cs_pin: GPIO14
|
|
|
|
|
can_id: 0x1fff
|
2021-07-28 23:56:11 +02:00
|
|
|
|
use_extended_id: true
|
2020-12-21 20:27:24 +01:00
|
|
|
|
bit_rate: 125kbps
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: 0x123
|
2021-07-28 23:56:11 +02:00
|
|
|
|
use_extended_id: true
|
2020-12-21 20:27:24 +01:00
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
std::string b(x.begin(), x.end());
|
|
|
|
|
ESP_LOGD("can extended id 0x123", "%s", &b[0] );
|
|
|
|
|
- can_id: 0x123
|
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
std::string b(x.begin(), x.end());
|
|
|
|
|
ESP_LOGD("can standard id 0x123", "%s", &b[0] );
|
|
|
|
|
|
|
|
|
|
Binary Sensor Example
|
|
|
|
|
---------------------
|
|
|
|
|
Example for the following application:
|
|
|
|
|
Button is connected on a can node which sends an A message on ID 0x100 with payload 0x01 for contact closed and 0x00 for contact open.
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
spi:
|
|
|
|
|
id: McpSpi
|
|
|
|
|
clk_pin: GPIO16
|
|
|
|
|
mosi_pin: GPIO5
|
|
|
|
|
miso_pin: GPIO4
|
|
|
|
|
|
|
|
|
|
binary_sensor:
|
|
|
|
|
- platform: template
|
|
|
|
|
name: "CAN Bus Button"
|
|
|
|
|
id: "can_bus_button"
|
|
|
|
|
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: mcp2515
|
|
|
|
|
id: my_mcp2515
|
|
|
|
|
spi_id: McpSpi
|
|
|
|
|
cs_pin: GPIO14
|
|
|
|
|
can_id: 4
|
|
|
|
|
bit_rate: 125kbps
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: ${0x100}
|
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
if(x.size() > 0) {
|
|
|
|
|
switch(x[0]) {
|
|
|
|
|
case 0x0: id(can_bus_button).publish_state(false); break; // button release
|
|
|
|
|
case 0x1: id(can_bus_button).publish_state(true); break; // button down
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
Cover Example
|
|
|
|
|
-------------
|
|
|
|
|
Example for following application:
|
|
|
|
|
Buttons are connected on the CAN-Node and also the motor is connected via CAN.
|
|
|
|
|
|
|
|
|
|
.. epigraph::
|
|
|
|
|
|
2021-02-07 17:35:39 +01:00
|
|
|
|
| **Button 1:** ID 0x50B - 1 byte payload
|
2020-12-21 20:27:24 +01:00
|
|
|
|
| (0: Button release, 1: Button down, 2: long down, 3: long release, 4 double click)
|
2021-02-07 17:35:39 +01:00
|
|
|
|
| **Button 2:** ID 0x50C - 1 byte payload
|
2020-12-21 20:27:24 +01:00
|
|
|
|
| (0: Button release, 1: Button down, 2: long down, 3: long release, 4 double click)
|
2021-02-07 17:35:39 +01:00
|
|
|
|
| **Motor:** ID 0x51A - 1 byte payload
|
2020-12-21 20:27:24 +01:00
|
|
|
|
| (0: off, 1: open, 2: close)
|
|
|
|
|
|
|
|
|
|
.. code-block:: yaml
|
|
|
|
|
|
|
|
|
|
spi:
|
|
|
|
|
id: McpSpi
|
|
|
|
|
clk_pin: GPIO16
|
|
|
|
|
mosi_pin: GPIO5
|
|
|
|
|
miso_pin: GPIO4
|
|
|
|
|
|
|
|
|
|
canbus:
|
|
|
|
|
- platform: mcp2515
|
|
|
|
|
id: my_mcp2515
|
|
|
|
|
spi_id: McpSpi
|
|
|
|
|
cs_pin: GPIO14
|
|
|
|
|
can_id: 4
|
|
|
|
|
bit_rate: 125kbps
|
|
|
|
|
on_frame:
|
|
|
|
|
- can_id: 0x50c
|
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
if(x.size() > 0) {
|
|
|
|
|
auto call = id(TestCover).make_call();
|
|
|
|
|
switch(x[0]) {
|
|
|
|
|
case 0x2: call.set_command_open(); call.perform(); break; // long pressed
|
|
|
|
|
case 0x1: // button down
|
|
|
|
|
case 0x3: call.set_command_stop(); call.perform(); break; // long released
|
|
|
|
|
case 0x4: call.set_position(1.0); call.perform(); break; // double click
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
- can_id: 0x50b
|
|
|
|
|
then:
|
|
|
|
|
- lambda: |-
|
|
|
|
|
if(x.size() > 0) {
|
|
|
|
|
auto call = id(TestCover).make_call();
|
|
|
|
|
switch(x[0]) {
|
|
|
|
|
case 0x2: call.set_command_close(); call.perform(); break; // long pressed
|
|
|
|
|
case 0x1: // button down
|
|
|
|
|
case 0x3: call.set_command_stop(); call.perform(); break; // long released
|
|
|
|
|
case 0x4: call.set_position(0.0); call.perform(); break; // double click
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
cover:
|
|
|
|
|
- platform: time_based
|
|
|
|
|
name: "MyCanbusTestCover"
|
|
|
|
|
id: TestCover
|
|
|
|
|
device_class: shutter
|
|
|
|
|
has_built_in_endstop: true
|
|
|
|
|
open_action:
|
|
|
|
|
- canbus.send:
|
|
|
|
|
data: [ 0x01 ]
|
|
|
|
|
canbus_id: my_mcp2515
|
|
|
|
|
can_id: 0x51A
|
|
|
|
|
open_duration: 2min
|
|
|
|
|
close_action:
|
|
|
|
|
- canbus.send:
|
|
|
|
|
data: [ 0x02 ]
|
|
|
|
|
canbus_id: my_mcp2515
|
|
|
|
|
can_id: 0x51A
|
|
|
|
|
close_duration: 2min
|
|
|
|
|
stop_action:
|
|
|
|
|
- canbus.send:
|
|
|
|
|
data: [ 0x00 ]
|
|
|
|
|
canbus_id: my_mcp2515
|
|
|
|
|
can_id: 0x51A
|
|
|
|
|
|
|
|
|
|
See Also
|
|
|
|
|
--------
|
|
|
|
|
|
|
|
|
|
- :apiref:`spi/spi.h`
|
|
|
|
|
- :ghedit:`Edit`
|