2022-09-14 06:51:28 +02:00
uFire ISE pH sensor
===================
.. seo ::
:description: Instructions for setting up uFire ISE pH sensor in esphome
:image: ufire_ise.png
:keywords: ufire ph sensor temperature esphome
The `` ufire_ise `` sensor platform allows you to use your uFire ISE pH sensor with
ESPHome. The :ref: `I²C Bus <i2c>` is
required to be set up in your configuration for this sensor to work.
It required also to have an temperature sensor in the liquit tank; this can
be on the same board or external sensor linked to the uFire ISE pH configuration.
.. figure :: images/ufire_ise.png
:align: center
:width: 100.0%
.. code-block :: yaml
# Example configuration entry
sensor:
2023-01-24 18:56:46 +01:00
- platform: ufire_ise
2022-09-14 06:51:28 +02:00
id: ufire_ise_board
temperature:
id: temperature_liquit
name: Temperature
ph:
name: pH
Configuration variables:
------------------------
2023-01-24 18:56:46 +01:00
- **address** (*Optional* , int): Specify the I²C address of the sensor. Defaults to `` 0x3f `` .
2022-09-14 06:51:28 +02:00
- **update_interval** (*Optional* , :ref: `config-time` ): The interval to check the
sensor. Defaults to `` 60s `` .
- **id** (*Optional* , :ref: `config-id` ): Set the ID of this sensor for use in lambdas.
- **temperature_sensor** (*Optional* , :ref: `config-id` ): Set the ID of the temperature
sensor. Only needed if the onboard temperature sensor is not used.
- **ph** (*Optional* , :ref: `Sensor <config-sensor>` ): Set the pH sensor configuration. All options from :ref: `Sensor <config-sensor>` .
- **temperature** (*Optional* , :ref: `Sensor <config-sensor>` ): Set the onboard temperature sensor configuration. All options from :ref: `Sensor <config-sensor>` .
Can't be used together with `` temperature_sensor `` .
.. _sensor-ufire_ise-calibrate_probe_high_action:
2023-01-24 18:56:46 +01:00
`` ufire_ise.calibrate_probe_high `` Action
-----------------------------------------
2022-09-14 06:51:28 +02:00
The pH probe have to be calibrated. For this you need know the pH reference value and temperature
of the calibration high solution.
.. code-block :: yaml
# Example configuration entry
sensor:
- platform: ufire_ise
id: ufire_ise_board
# ...
# in some trigger
on_...:
- sensor.ufire_ise_board.calibrate_probe_high:
id: ufire_ise_board
solution: 7.0
temperature: !lambda "return id(temperature_liquit).state;"
Configuration options:
- **id** (**Required** , :ref: `config-id` ): The ID of the ufire pH sensor.
- **solution** (**Required** , float): Solution reference pH value.
.. _sensor-ufire_ise-calibrate_probe_low_action:
2023-01-24 18:56:46 +01:00
`` ufire_ise.calibrate_probe_low `` Action
----------------------------------------
2022-09-14 06:51:28 +02:00
The pH probe have to be calibrated. For this you need know the pH reference value and temperature
of the calibration low solution.
.. code-block :: yaml
# Example configuration entry
sensor:
- platform: ufire_ise
id: ufire_ise_board
# ...
# in some trigger
on_...:
- sensor.ufire_ise_board.calibrate_probe_low:
id: ufire_ise_board
solution: 4.0
temperature: !lambda "return id(temperature_liquit).state;"
Configuration options:
- **id** (**Required** , :ref: `config-id` ): The ID of the ufire pH sensor.
- **solution** (**Required** , float): Solution reference pH value.
.. _sensor-ufire_ise-reset_action:
2023-01-24 18:56:46 +01:00
`` ufire_ise.reset `` Action
--------------------------
2022-09-14 06:51:28 +02:00
Reset the current calibration on the sensor.
.. code-block :: yaml
# Example configuration entry
sensor:
- platform: ufire_ise
id: ufire_ise_board
# ...
# in some trigger
on_...:
- sensor.ufire_ise_board.reset:
id: ufire_ise_board
Configuration options:
- **id** (**Required** , :ref: `config-id` ): The ID of the ufire pH sensor.
See Also
--------
- :ref: `sensor-filters`
- :apiref: `ufire_ise/ufire_ise.h`
- :ghedit: `Edit`