CSE7766 Power Sensor
====================
2018-11-14 22:12:27 +01:00
.. seo ::
:description: Instructions for setting up CSE7766 power sensors for the Sonoff Pow R2
2021-11-16 03:19:33 +01:00
:image: cse7766.svg
2021-05-10 00:01:02 +02:00
:keywords: cse7766, cse7759b, Sonoff Pow R2
2018-11-14 22:12:27 +01:00
2018-10-17 21:00:30 +02:00
The `` cse7766 `` sensor platform allows you to use your CSE7766 voltage/current and power sensors
(`datasheet <http://dl.itead.cc/S31/CSE7766.pdf> `__ ) sensors with
2021-05-10 00:01:02 +02:00
ESPHome. This sensor is commonly found in Sonoff POW R2. CSE7759B is similar to CSE7766
and works with this integration.
2018-10-17 21:00:30 +02:00
2021-05-17 17:05:55 +02:00
.. note ::
SAFETY HAZARD: Some devices such as Sonoff POWs/Shelly/etc, have the digital GND connected directly to mains voltage so **the GPIOs become LIVE during normal operation** . Our advice is to mark these boards to prevent any use of the dangerous digital pins.
2018-10-17 21:00:30 +02:00
As the communication with the CSE7766 done using UART, you need
to have an :ref: `UART bus <uart>` in your configuration with the `` rx_pin `` connected to the CSE7766.
2018-10-27 13:19:51 +02:00
Additionally, you need to set the baud rate to 4800.
2018-10-17 21:00:30 +02:00
2018-11-19 18:32:16 +01:00
.. code-block :: yaml
2018-10-17 21:00:30 +02:00
# Example configuration entry
# Disable logging over USB
logger:
baud_rate: 0
uart:
rx_pin: RX
2018-10-27 13:19:51 +02:00
baud_rate: 4800
2018-10-17 21:00:30 +02:00
sensor:
- platform: cse7766
current:
name: "Sonoff Pow R2 Current"
voltage:
name: "Sonoff Pow R2 Voltage"
power:
name: "Sonoff Pow R2 Power"
2021-11-30 16:08:06 +01:00
energy:
name: "Sonoff Pow R2 Energy"
2018-10-17 21:00:30 +02:00
.. note ::
The configuration above should work for Sonoff POWs (R2).
Configuration variables:
------------------------
- **current** (*Optional* ): Use the current value of the sensor in amperes. All options from
2019-02-17 12:28:17 +01:00
:ref: `Sensor <config-sensor>` .
2018-10-17 21:00:30 +02:00
- **power** (*Optional* ): Use the (active) power value of the sensor in watts. All options from
2019-02-17 12:28:17 +01:00
:ref: `Sensor <config-sensor>` .
2018-10-17 21:00:30 +02:00
- **voltage** (*Optional* ): Use the voltage value of the sensor in V (RMS).
2019-02-17 12:28:17 +01:00
All options from :ref: `Sensor <config-sensor>` .
2021-11-30 16:08:06 +01:00
- **energy** (*Optional* ): Use the total energy value of the sensor in Wh.
All options from :ref: `Sensor <config-sensor>` .
2018-12-01 13:19:42 +01:00
- **update_interval** (*Optional* , :ref: `config-time` ): The interval to check the
2019-01-06 18:56:14 +01:00
sensor. Defaults to `` 60s `` .
2018-10-17 21:00:30 +02:00
- **uart_id** (*Optional* , :ref: `config-id` ): Manually specify the ID of the :ref: `UART Component <uart>` if you want
to use multiple UART buses.
See Also
--------
- :ref: `sensor-filters`
2019-05-12 22:44:59 +02:00
- :apiref: `cse7766/cse7766.h`
2019-02-07 13:54:45 +01:00
- :ghedit: `Edit`