esphome-docs/components/sensor/pzemac.rst

94 lines
3.2 KiB
ReStructuredText
Raw Normal View History

2019-10-20 19:23:59 +02:00
Peacefair PZEM-004T V3 Energy Monitor
=====================================
.. seo::
:description: Instructions for setting up PZEM-004T power monitors.
:image: pzemac.png
:keywords: PZEM-004T V3
.. note::
2021-08-29 13:10:40 +02:00
This page is incomplete and could use some work. If you want to contribute, please read the
2019-10-20 19:23:59 +02:00
:doc:`contributing guide </guides/contributing>`. This page is missing:
- Images/screenshots/example configs of this device being used in action.
The ``pzemac`` sensor platform allows you to use PZEM-004T V3 energy monitors
(`website <https://innovatorsguru.com/pzem-004t-v3/>`__,
`datasheet <https://innovatorsguru.com/wp-content/uploads/2019/06/PZEM-004T-V3.0-Datasheet-User-Manual.pdf>`__)
with ESPHome.
The sensor can be connected in various configurations - please see the `manufacturer's website <https://innovatorsguru.com/pzem-004t-v3/>`__
for more information.
.. figure:: images/pzem-ac.png
:align: center
:width: 80.0%
PZEM-004T Version 3.
2019-10-20 19:23:59 +02:00
.. warning::
This page refers to version V3 of the PZEM004T.
For using the older V1 variant of this sensor please see :doc:`pzem004t <pzem004t>`.
2021-08-03 13:36:12 +02:00
The communication with this integration is done over a :ref:`UART bus <uart>` using :ref:`Modbus <modbus>`.
2019-10-20 19:23:59 +02:00
You must therefore have a ``uart:`` entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600.
.. code-block:: yaml
# Example configuration entry
uart:
2019-10-20 19:23:59 +02:00
rx_pin: D1
tx_pin: D2
2019-10-20 19:23:59 +02:00
baud_rate: 9600
2021-08-03 13:36:12 +02:00
modbus:
2019-10-20 19:23:59 +02:00
sensor:
- platform: pzemac
current:
name: "PZEM-004T V3 Current"
voltage:
name: "PZEM-004T V3 Voltage"
2020-03-12 21:59:20 +01:00
energy:
name: "PZEM-004T V3 Energy"
2019-10-20 19:23:59 +02:00
power:
name: "PZEM-004T V3 Power"
frequency:
name: "PZEM-004T V3 Frequency"
power_factor:
name: "PZEM-004T V3 Power Factor"
update_interval: 60s
Configuration variables:
------------------------
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor <config-sensor>`.
2020-03-12 21:59:20 +01:00
- **energy** (*Optional*): Use the (active) energy value of the sensor in watt*hours. All options from
:ref:`Sensor <config-sensor>`.
2019-10-20 19:23:59 +02:00
- **power** (*Optional*): Use the (active) power value of the sensor in watts. All options from
:ref:`Sensor <config-sensor>`.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor <config-sensor>`.
- **frequency** (*Optional*): Use the frequency value of the sensor in hertz.
All options from :ref:`Sensor <config-sensor>`.
- **power_factor** (*Optional*): Use the power factor value of the sensor.
All options from :ref:`Sensor <config-sensor>`.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
- **address** (*Optional*, int): The address of the sensor if multiple sensors are attached to
the same UART bus. You will need to set the address of each device manually. Defaults to ``1``.
2021-08-03 13:36:12 +02:00
- **modbus_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the Modbus hub.
2019-10-20 19:23:59 +02:00
See Also
--------
- :ref:`sensor-filters`
- :doc:`pzem004t`
- :doc:`pzemdc`
- :apiref:`pzemac/pzemac.h`
- :ghedit:`Edit`