SHTCx Temperature+Humidity Sensors
|
||
|
==================================
|
||
|
|
||
|
.. seo::
|
||
|
:description: Instructions for setting up SHTC1 and SHTC3 temperature and humidity sensors
|
||
|
:image: shtc3.jpg
|
||
|
|
||
|
The ``shtcx`` sensor platform Temperature+Humidity sensor allows you to use your Sensiron SHTC1
|
||
|
(`datasheet <https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Humidity/Sensirion_Humidity_Sensors_SHTC1_Datasheet.pdf>`__,
|
||
|
`Sensirion STHC1 <https://www.sensirion.com/en/environmental-sensors/humidity-sensors/digital-humidity-sensor-for-consumer-electronics-and-iot/>`__) and
|
||
|
the newer SHTC3
|
||
|
(`datasheet <https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Humidity/Sensirion_Humidity_Sensors_SHTC3_Datasheet.pdf>`__,
|
||
|
`Sparkfun`_ ) sensors with
|
||
|
ESPHome. The :ref:`I²C Bus <i2c>` is
|
||
|
required to be set up in your configuration for this sensor to work.
|
||
|
|
||
|
.. _Sparkfun: https://www.sparkfun.com/products/15074
|
||
|
|
||
|
.. figure:: images/temperature-humidity.png
|
||
|
:align: center
|
||
|
:width: 80.0%
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
# Example configuration entry
|
||
|
sensor:
|
||
|
- platform: shtcx
|
||
|
temperature:
|
||
|
name: "Living Room Temperature"
|
||
|
humidity:
|
||
|
name: "Living Room Humidity"
|
||
|
address: 0x70
|
||
|
update_interval: 60s
|
||
|
|
||
|
Configuration variables:
|
||
|
------------------------
|
||
|
|
||
|
- **temperature** (**Required**): The information for the temperature sensor.
|
||
|
|
||
|
- **name** (**Required**, string): The name for the temperature sensor.
|
||
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
|
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
- **humidity** (**Required**): The information for the humidity sensor.
|
||
|
|
||
|
- **name** (**Required**, string): The name for the humidity sensor.
|
||
|
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||
|
- All other options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
- **address** (*Optional*, int): Manually specify the i^2c address of the sensor.
|
||
|
Defaults to ``0x70``.
|
||
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
||
|
sensor. Defaults to ``60s``.
|
||
|
|
||
|