mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-12-30 18:09:26 +01:00
151 lines
4.9 KiB
ReStructuredText
151 lines
4.9 KiB
ReStructuredText
|
Mopeka Standard Check BLE Sensor
|
||
|
================================
|
||
|
|
||
|
.. seo::
|
||
|
:description: Instructions for setting up Mopeka Standard Check bluetooth-based sensors in ESPHome.
|
||
|
:image: mopeka_std_check.jpg
|
||
|
:keywords: Mopeka, Mopeka Standard Check, Mopeka Std Check, BLE, Bluetooth
|
||
|
|
||
|
The ``mopeka_std_check`` sensor platform lets you track the output of Mopeka
|
||
|
Standard Check LP Bluetooth Low Energy devices using the
|
||
|
:doc:`/components/esp32_ble_tracker`. This component will track the tank level,
|
||
|
distance, temperature, and battery percentage of a Mopeka Standard Check LP BLE
|
||
|
device every time the sensor sends out a BLE broadcast.
|
||
|
|
||
|
.. warning::
|
||
|
|
||
|
This sensor component only supports the Mopeka Standard Check devices.
|
||
|
See :doc:`/components/sensor/mopeka_pro_check` for Mopeka Pro Check sensors support.
|
||
|
|
||
|
.. figure:: images/mopeka_std_check.jpg
|
||
|
:align: center
|
||
|
|
||
|
Mopeka Std Check LP over BLE.
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
esp32_ble_tracker:
|
||
|
|
||
|
sensor:
|
||
|
# Example using 11kg 100% propane tank.
|
||
|
- platform: mopeka_std_check
|
||
|
mac_address: D3:75:F2:DC:16:91
|
||
|
tank_type: Europe_11kg
|
||
|
temperature:
|
||
|
name: "Propane test temp"
|
||
|
level:
|
||
|
name: "Propane test level"
|
||
|
distance:
|
||
|
name: "Propane test distance"
|
||
|
battery_level:
|
||
|
name: "Propane test battery level"
|
||
|
|
||
|
# Custom example - user defined empty / full points and 80% butane and 20% propane.
|
||
|
- platform: mopeka_std_check
|
||
|
mac_address: D3:75:F2:DC:16:91
|
||
|
tank_type: CUSTOM
|
||
|
custom_distance_full: 40cm
|
||
|
custom_distance_empty: 32mm
|
||
|
propane_butane_mix: 20%
|
||
|
temperature:
|
||
|
name: "Propane c test temp"
|
||
|
level:
|
||
|
name: "Propane c test level"
|
||
|
distance:
|
||
|
name: "Propane c test distance"
|
||
|
battery_level:
|
||
|
name: "Propane c test battery level"
|
||
|
|
||
|
|
||
|
Configuration variables:
|
||
|
------------------------
|
||
|
|
||
|
- **mac_address** (**Required**, MAC Address): The MAC address of the Mopeka
|
||
|
device.
|
||
|
|
||
|
- **tank_type** (**Required**): The tank type the sensor is measuring. See below.
|
||
|
|
||
|
- **custom_distance_full** (*Optional*): distance sensor will read when it should be
|
||
|
considered full (100%). This is only used when tank_type = CUSTOM
|
||
|
|
||
|
- **custom_distance_empty** (*Optional*): distance sensor will read when it should be
|
||
|
considered empty (0%). This is only used when tank_type = CUSTOM
|
||
|
|
||
|
- **propane_butane_mix** (*Optional*): Mixture of propane and butane.
|
||
|
|
||
|
- 100% - (*default*) 100% Propane
|
||
|
|
||
|
- 80% - 80% Propane and 20% Butane
|
||
|
|
||
|
- 20% - 20% Propane and 80% Butane
|
||
|
|
||
|
- 0% - 100% Butane
|
||
|
|
||
|
- **level** (*Optional*): The percentage of full for the tank sensor
|
||
|
|
||
|
- All options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
- **distance** (*Optional*): The raw distance/depth of the liquid for the sensor in mm.
|
||
|
|
||
|
- All options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
- **temperature** (*Optional*): The information for the temperature sensor.
|
||
|
This temperature is on the sensor and is not calibrated to ambient temperature.
|
||
|
|
||
|
- All options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
- **battery_level** (*Optional*): The information for the battery percentage
|
||
|
sensor. Sensor uses a standard CR2032 battery.
|
||
|
|
||
|
- All options from :ref:`Sensor <config-sensor>`.
|
||
|
|
||
|
Tank Types
|
||
|
----------
|
||
|
|
||
|
Currently supported Tank types are:
|
||
|
|
||
|
- ``NORTH_AMERICA_20LB_VERTICAL`` - 20 LB vertical tank
|
||
|
- ``NORTH_AMERICA_30LB_VERTICAL`` - 30 LB vertical tank
|
||
|
- ``NORTH_AMERICA_40LB_VERTICAL`` - 40 LB vertical tank
|
||
|
- ``EUROPE_6KG`` - 6kg vertical tank
|
||
|
- ``EUROPE_11KG`` - 11kg vertical tank
|
||
|
- ``EUROPE_14KG`` - 14kg vertical tank
|
||
|
- ``CUSTOM`` - Allows you to define your own full and empty points
|
||
|
|
||
|
Setting Up Devices
|
||
|
------------------
|
||
|
|
||
|
To set up Mopeka Standard Check devices you first need to find their MAC Address so that
|
||
|
ESPHome can identify them. So first, create a simple configuration with the ``esp32_ble_tracker``
|
||
|
and the ``mopeka_ble`` component like so:
|
||
|
|
||
|
.. code-block:: yaml
|
||
|
|
||
|
esp32_ble_tracker:
|
||
|
|
||
|
mopeka_ble:
|
||
|
|
||
|
After uploading, the ESP32 will immediately try to scan for BLE devices. For Mopeka Standard devices you must press and hold the green sync button for it to be identified.
|
||
|
Or alternativly set the configuration flag ``show_sensors_without_sync: true`` to see all devices.
|
||
|
For all sensors found the ``mopeka_ble`` component will print a message like this one:
|
||
|
|
||
|
.. code::
|
||
|
|
||
|
[20:43:26][I][mopeka_ble:056]: MOPEKA STD (CC2540) SENSOR FOUND: D3:75:F2:DC:16:91
|
||
|
|
||
|
Then just copy the address (``D3:75:F2:DC:16:91``) into a new
|
||
|
``sensor.mopeka_std_check`` platform entry like in the configuration example at the top.
|
||
|
|
||
|
.. note::
|
||
|
|
||
|
The ESPHome Mopeka Standard Check BLE integration listens passively to packets the Mopeka device sends by itself.
|
||
|
ESPHome therefore has no impact on the battery life of the device.
|
||
|
|
||
|
See Also
|
||
|
--------
|
||
|
|
||
|
- :doc:`/components/esp32_ble_tracker`
|
||
|
- :doc:`/components/sensor/index`
|
||
|
- :apiref:`mopeka_std_check/mopeka_std_check.h`
|
||
|
- :ghedit:`Edit`
|