@ -6,10 +6,10 @@ Thermostat Climate Controller
|
|||||||
:image: air-conditioner.svg
|
:image: air-conditioner.svg
|
||||||
|
|
||||||
The ``thermostat`` climate platform allows you to control a climate control system in much the same manner as a
|
The ``thermostat`` climate platform allows you to control a climate control system in much the same manner as a
|
||||||
physical thermostat. Its operation is similar to the :doc:`bang-bang <bang_bang>` controller; a sensor measures a value
|
physical thermostat. Its operation is similar to the :doc:`Bang-Bang <bang_bang>` controller; a sensor measures a value
|
||||||
(the air temperature) and the controller will try to keep this value within a range defined by the set point(s). To do this,
|
(the air temperature) and the controller will try to keep this value within a range defined by the set point(s). To do this,
|
||||||
the controller can activate devices like a heating unit and/or a cooling unit to change the value observed by the sensor.
|
the controller can activate devices like a heating unit and/or a cooling unit to change the value observed by the sensor.
|
||||||
When configured for both heating and cooling, it is essentially two :doc:`bang-bang <bang_bang>` controllers in one; it
|
When configured for both heating and cooling, it is essentially two :doc:`Bang-Bang <bang_bang>` controllers in one; it
|
||||||
differs, however, in that interaction with the thermostat component is nearly identical to that of a real thermostat.
|
differs, however, in that interaction with the thermostat component is nearly identical to that of a real thermostat.
|
||||||
|
|
||||||
This component can operate in one of two ways:
|
This component can operate in one of two ways:
|
||||||
@ -169,45 +169,6 @@ The thermostat controller uses the sensor to determine whether it should heat or
|
|||||||
|
|
||||||
- **sensor** (**Required**, :ref:`config-id`): The sensor that is used to measure the current temperature.
|
- **sensor** (**Required**, :ref:`config-id`): The sensor that is used to measure the current temperature.
|
||||||
|
|
||||||
Default Target Temperatures and Mode
|
|
||||||
************************************
|
|
||||||
|
|
||||||
These configuration items determine default values the thermostat controller should use when it starts.
|
|
||||||
|
|
||||||
- **default_mode** (*Optional*, *Deprecated*, climate mode): The default climate mode the controller should
|
|
||||||
use if it is unable to restore it from memory. One of:
|
|
||||||
|
|
||||||
- ``off`` (default)
|
|
||||||
- ``heat_cool``
|
|
||||||
- ``cool``
|
|
||||||
- ``heat``
|
|
||||||
- ``dry``
|
|
||||||
- ``fan_only``
|
|
||||||
- ``auto``
|
|
||||||
|
|
||||||
This value is used the first time your device starts after ESPHome is initially installed onto it. Add
|
|
||||||
this option into your configuration if you want your thermostat component to start in a climate mode other
|
|
||||||
than ``off``. If this option is not configured, you'll need to manually change the climate mode later via
|
|
||||||
the front end (Home Assistant), an ESPHome action, automation, or from within a lambda elsewhere in your
|
|
||||||
device's configuration.
|
|
||||||
|
|
||||||
- **default_target_temperature_low** (*Optional*, float): The default low target
|
|
||||||
temperature for the control algorithm. This can be dynamically set in the frontend later.
|
|
||||||
- **default_target_temperature_high** (*Optional*, float): The default high target
|
|
||||||
temperature for the control algorithm. This can be dynamically set in the frontend later.
|
|
||||||
|
|
||||||
**At least one of** ``default_target_temperature_low`` **and** ``default_target_temperature_high``
|
|
||||||
**must be specified.**
|
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
**default_mode**, **default_target_temperature_low**, and **default_target_temperature_high** are
|
|
||||||
being removed in a future release. In the future you will need to migrate your configuration to using
|
|
||||||
a :ref:`preset <thermostat-preset>` which will allow for more flexibility and customisation
|
|
||||||
|
|
||||||
Note that ``min_temperature`` and ``max_temperature`` from the base climate component are used to define
|
|
||||||
the range of allowed temperature values in the thermostat component. See :doc:`/components/climate/index`.
|
|
||||||
|
|
||||||
Heating and Cooling Actions
|
Heating and Cooling Actions
|
||||||
***************************
|
***************************
|
||||||
|
|
||||||
@ -527,6 +488,9 @@ Additional Actions/Behavior
|
|||||||
- **min_fan_mode_switching_time** (*Required with any* ``fan_mode`` *action*, :ref:`config-time`): Minimum duration
|
- **min_fan_mode_switching_time** (*Required with any* ``fan_mode`` *action*, :ref:`config-time`): Minimum duration
|
||||||
any given fan mode must be active before it may be changed.
|
any given fan mode must be active before it may be changed.
|
||||||
|
|
||||||
|
Note that ``min_temperature`` and ``max_temperature`` from the base climate component are used to define
|
||||||
|
the range of allowed temperature values in the thermostat component. See :doc:`/components/climate/index`.
|
||||||
|
|
||||||
Hysteresis Values
|
Hysteresis Values
|
||||||
*****************
|
*****************
|
||||||
|
|
||||||
@ -547,15 +511,16 @@ Hysteresis Values
|
|||||||
adjustability and the defaults will probably not make sense for control of things like humidity. See
|
adjustability and the defaults will probably not make sense for control of things like humidity. See
|
||||||
:doc:`/components/climate/index`.
|
:doc:`/components/climate/index`.
|
||||||
|
|
||||||
Bang-bang vs. Thermostat
|
Bang-Bang vs. Thermostat
|
||||||
------------------------
|
------------------------
|
||||||
|
|
||||||
Please see the :doc:`Bang-bang <bang_bang>` component's documentation for a detailed comparison of these two components.
|
Please see the :doc:`Bang-Bang <bang_bang>` component's documentation for a detailed comparison of these two components.
|
||||||
|
|
||||||
See Also
|
See Also
|
||||||
--------
|
--------
|
||||||
|
|
||||||
- :doc:`/components/climate/index`
|
- :doc:`/components/climate/index`
|
||||||
- :doc:`/components/sensor/index`
|
- :doc:`/components/sensor/index`
|
||||||
|
- :doc:`Bang-Bang <bang_bang>`
|
||||||
- :ref:`config-action`
|
- :ref:`config-action`
|
||||||
- :ghedit:`Edit`
|
- :ghedit:`Edit`
|
||||||
|