@ -24,7 +24,8 @@ global ``pca9685`` hub and give it an id, and then define the
|
||||
|
||||
# Example configuration entry
|
||||
pca9685:
|
||||
frequency: 500
|
||||
- id: pca9685_hub1
|
||||
frequency: 500
|
||||
|
||||
# Individual outputs
|
||||
output:
|
||||
|
@ -224,7 +224,7 @@ This :ref:`action <config-action>` a Nexa RF remote code to a remote transmitter
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
- remote_transmitter.nexa:
|
||||
- remote_transmitter.transmit_nexa:
|
||||
device: 0x38DDB4A
|
||||
state: 1
|
||||
group: 0
|
||||
|
@ -138,7 +138,7 @@ Here are common current calibrations for the **Expandable 6 Channel Energy Meter
|
||||
- 20A/25mA SCT-006: 11131
|
||||
- 30A/1V SCT-013-030: 8650
|
||||
- 50A/1V SCT-013-050: 15420
|
||||
- 80A/26.6mA SCT-010: 41996
|
||||
- 80A/26.6mA SCT-010: 41996 (note this will saturate at 2^16/10^3 amps)
|
||||
- 100A/50ma SCT-013-000: 27961
|
||||
- 120A/40mA: SCT-016: 41880
|
||||
|
||||
@ -172,6 +172,28 @@ a time-series-database, e.g. InfluxDB.
|
||||
id: ct1RAWattHours
|
||||
state_topic: ${disp_name}/ct1/reverse_active_energy
|
||||
|
||||
If the power, power_factor, reactive_power, forward_active_energy, or reverse_active_energy configuraion variables
|
||||
are used, care must be taken to ensure that the line ATM90E32's voltage is from is the same phase as the current
|
||||
transformer is installed on. This is significant in split-phase or multi phase installations. On a house with 240
|
||||
split-phase wiring (very common in the US), one simple test is to reverse the orentation of the current transformer
|
||||
on a line. If the power factor doesn't change sign, it is likely that the voltage fed to the ATM90E32 is from the other
|
||||
phase.
|
||||
|
||||
The CircuitSetup Expandable 6 channel board can easilly handle this situation by cutting the jumpers JP12/13 to
|
||||
allow a seperate VA2 to be input on the J3 pads. Make sure that current taps connected to CT 1-3 are on the phase
|
||||
from which VA is fed (the barrel jack) and the taps connected to CT3-6 are on the phase from which VA2 is fed. See
|
||||
the CicuitSetup repo for more details on this.
|
||||
|
||||
If a mulit board stack is being used, remember to cut JP12/13 on all boards and to feed VA2 to each board. VA is
|
||||
fed to all boards through the stacking headers. Another detail is that each voltage transformer needs to have the
|
||||
same polarity; getting this backwards will be just like having it on the wrong phase.
|
||||
|
||||
Note that the current measurement is the RMS value so is always positive. They only way to determine directon is to
|
||||
look at the power factor. If there are only largly resistive loads and no power sources, (PF almost 1), it is simpler
|
||||
to just create a template sensor that computes power from Irms*Vrms and ignore all these details. On the other
|
||||
hand, one might be surprised how reactive some loads are and the CirciuitSetup designs are able to
|
||||
handle these situations well.
|
||||
|
||||
|
||||
Additional Examples
|
||||
-------------------
|
||||
|
@ -11,6 +11,12 @@ The ``tcs34725`` sensor platform allows you to use your TCS34725 RGB color senso
|
||||
`Adafruit`_), color temperature and illuminance sensors with ESPHome. The :ref:`I²C <i2c>` is
|
||||
required to be set up in your configuration for this sensor to work.
|
||||
|
||||
Note: If the `integration_time` is set too long for the light conditions, the sensor will overexpose.
|
||||
In this case the sensor may not show 100% on its clear channel. With an `integration_time` of `614ms`
|
||||
and a `gain` of `1x` the sensor will max out at around 4100 lx. In this case the individual color
|
||||
channels will show `100%`, the clear channel `25%`. The illumination in lux is shown as `0` as well
|
||||
as the color temperature in kelvin will show `0`.
|
||||
|
||||
.. figure:: images/tcs34725-full.jpg
|
||||
:align: center
|
||||
:width: 50.0%
|
||||
|
@ -118,3 +118,4 @@ Sample Configurations
|
||||
- `ESPHome floor heating controller (proportional valves) <https://github.com/nliaudat/floor-heating-controller>`__ by :ghuser:`nliaudat`
|
||||
- `ESPHome Curtain/Cover/Shutter Switch from a noname Tuya switch <https://github.com/ludrao/esphome-shutterswitch>`__ by :ghuser:`ludrao`
|
||||
- `ESPHome Free your Thomson Guardian gate controller <https://github.com/ludrao/esphome-guardian>`__ by :ghuser:`ludrao`
|
||||
- `Ambient Light Sensor tcs34725 example <https://gist.github.com/RubenKelevra/0d70d6b4c8e4bc9aedc8682865731d65>`__ by :ghuser:`RubenKelevra`
|
||||
|
@ -350,8 +350,13 @@ And a docker compose file looks like this:
|
||||
- ./:/config:rw
|
||||
# Use local time for logging timestamps
|
||||
- /etc/localtime:/etc/localtime:ro
|
||||
devices:
|
||||
# if needed, add esp device(s) as in command line examples above
|
||||
- /dev/ttyUSB0:/dev/ttyUSB0
|
||||
- /dev/ttyACM0:/dev/ttyACM0
|
||||
network_mode: host
|
||||
restart: always
|
||||
|
||||
|
||||
.. _docker-reference-notes:
|
||||
.. note::
|
||||
|
Loading…