mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-11-10 10:11:29 +01:00
Fix example YAML for Haier climate component (#4096)
* Fix example YAML for Haier climate component The valid value is `hon` and not `h0n`. Did same PR for source component https://github.com/paveldn/haier-esphome/pull/48 * Update haier.rst - Consequently replace `h0n` with `hon` in all the examples - Put values in text fields to conform docs site styling --------- Co-authored-by: H. Árkosi Róbert <robreg@zsurob.hu>
This commit is contained in:
parent
2bdb8a781b
commit
15032c2892
@ -61,7 +61,7 @@ This component requires a :ref:`uart` to be setup.
|
||||
climate:
|
||||
- platform: haier
|
||||
id: haier_ac
|
||||
protocol: hOn
|
||||
protocol: hon
|
||||
name: Haier AC
|
||||
uart_id: ac_port
|
||||
wifi_signal: true
|
||||
@ -113,23 +113,23 @@ Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code generation.
|
||||
- **uart_id** (*Optional*, :ref:`config-id`): ID of the UART port to communicate with AC.
|
||||
- **protocol** (*Optional*, string): Defines communication protocol with AC. Possible values: hon or smartair2. The default value is smartair2.
|
||||
- **protocol** (*Optional*, string): Defines communication protocol with AC. Possible values: ``hon`` or ``smartair2``. The default value is ``smartair2``.
|
||||
- **name** (**Required**, string): The name of the climate device.
|
||||
- **wifi_signal** (*Optional*, boolean): If true - send wifi signal level to AC.
|
||||
- **answer_timeout** (*Optional*, :ref:`config-time`): Responce timeout. The default value is 200ms.
|
||||
- **alternative_swing_control** (*Optional*, boolean): (supported by smartAir2 only) If true - use alternative values to control swing mode. Use only if the original control method is not working for your AC.
|
||||
- **status_message_header_size** (*Optional*, int): (supported only by hOn) Define the header size of the status message. Can be used to handle some protocol variations. Use only if you are sure what you are doing. The default value: 0.
|
||||
- **control_packet_size** (*Optional*, int): (supported only by hOn) Define the size of the control packet. Can help with some newer models of ACs that use bigger packets. The default value: 10.
|
||||
- **sensors_packet_size** (*Optional*, int): (supported only by hOn) Define the size of the sensor packet of the status message. Can help with some models of ACs that have bigger sensor packet. The default value: 22, minimum value: 18.
|
||||
- **control_method** (*Optional*, list): (supported only by hOn) Defines control method (should be supported by AC). Supported values: MONITOR_ONLY - no control, just monitor status, SET_GROUP_PARAMETERS - set all AC parameters with one command (default method), SET_SINGLE_PARAMETER - set each parameter individually (this method is supported by some new ceiling ACs like AD71S2SM3FA)
|
||||
- **wifi_signal** (*Optional*, boolean): If ``true`` - send wifi signal level to AC.
|
||||
- **answer_timeout** (*Optional*, :ref:`config-time`): Responce timeout. The default value is ``200ms``.
|
||||
- **alternative_swing_control** (*Optional*, boolean): (supported by smartAir2 only) If ``true`` - use alternative values to control swing mode. Use only if the original control method is not working for your AC.
|
||||
- **status_message_header_size** (*Optional*, int): (supported only by hOn) Define the header size of the status message. Can be used to handle some protocol variations. Use only if you are sure what you are doing. The default value: ``0``.
|
||||
- **control_packet_size** (*Optional*, int): (supported only by hOn) Define the size of the control packet. Can help with some newer models of ACs that use bigger packets. The default value: ``10``.
|
||||
- **sensors_packet_size** (*Optional*, int): (supported only by hOn) Define the size of the sensor packet of the status message. Can help with some models of ACs that have bigger sensor packet. The default value: ``22``, minimum value: ``18``.
|
||||
- **control_method** (*Optional*, list): (supported only by hOn) Defines control method (should be supported by AC). Supported values: ``MONITOR_ONLY`` - no control, just monitor status, ``SET_GROUP_PARAMETERS`` - set all AC parameters with one command (default method), ``SET_SINGLE_PARAMETER`` - set each parameter individually (this method is supported by some new ceiling ACs like AD71S2SM3FA)
|
||||
- **display** (*Optional*, boolean): Can be used to set the AC display off.
|
||||
- **beeper** (*Optional*, boolean): Can be used to disable beeping on commands from AC. Supported only by hOn protocol.
|
||||
- **supported_modes** (*Optional*, list): Can be used to disable some of AC modes. Possible values: 'OFF', HEAT_COOL, COOL, HEAT, DRY, FAN_ONLY
|
||||
- **supported_swing_modes** (*Optional*, list): Can be used to disable some swing modes if your AC does not support it. Possible values: 'OFF', VERTICAL, HORIZONTAL, BOTH
|
||||
- **supported_presets** (*Optional*, list): Can be used to disable some presets. Possible values for smartair2 are: AWAY, BOOST, COMFORT. Possible values for hOn are: AWAY, ECO, BOOST, SLEEP. AWAY preset can be enabled only in HEAT mode, it is disabled by default
|
||||
- **on_alarm_start** (*Optional*, :ref:`Automation <automation>`): (supported only by hOn) Automation to perform when AC activates a new alarm. See :ref:`haier-on_alarm_start`
|
||||
- **on_alarm_end** (*Optional*, :ref:`Automation <automation>`): (supported only by hOn) Automation to perform when AC deactivates a new alarm. See :ref:`haier-on_alarm_end`
|
||||
- **on_status_message** (*Optional*, :ref:`Automation <automation>`): Automation to perform when status message received from AC. See :ref:`haier-on_status_message`
|
||||
- **supported_modes** (*Optional*, list): Can be used to disable some of AC modes. Possible values: ``'OFF'``, ``HEAT_COOL``, ``COOL``, ``HEAT``, ``DRY``, ``FAN_ONLY``.
|
||||
- **supported_swing_modes** (*Optional*, list): Can be used to disable some swing modes if your AC does not support it. Possible values: ``'OFF'``, ``VERTICAL``, ``HORIZONTAL``, ``BOTH``.
|
||||
- **supported_presets** (*Optional*, list): Can be used to disable some presets. Possible values for smartair2 are: ``AWAY``, ``BOOST``, ``COMFORT``. Possible values for hOn are: ``AWAY``, ``ECO``, ``BOOST``, ``SLEEP``. ``AWAY`` preset can be enabled only in ``HEAT`` mode, it is disabled by default.
|
||||
- **on_alarm_start** (*Optional*, :ref:`Automation <automation>`): (supported only by hOn) Automation to perform when AC activates a new alarm. See :ref:`haier-on_alarm_start`.
|
||||
- **on_alarm_end** (*Optional*, :ref:`Automation <automation>`): (supported only by hOn) Automation to perform when AC deactivates a new alarm. See :ref:`haier-on_alarm_end`.
|
||||
- **on_status_message** (*Optional*, :ref:`Automation <automation>`): Automation to perform when status message received from AC. See :ref:`haier-on_status_message`.
|
||||
- All other options from :ref:`Climate <config-climate>`.
|
||||
|
||||
Automations
|
||||
@ -140,12 +140,12 @@ Automations
|
||||
``on_alarm_start`` Trigger
|
||||
**************************
|
||||
|
||||
This automation will be triggered when a new alarm is activated by AC. The error code of the alarm will be given in the variable ``code`` (``uint8_t``), error message in the variable ``message`` (``const char *``). Those variables can be used in :ref:`lambdas <config-lambda>`
|
||||
This automation will be triggered when a new alarm is activated by AC. The error code of the alarm will be given in the variable ``code`` (``uint8_t``), error message in the variable ``message`` (``const char *``). Those variables can be used in :ref:`lambdas <config-lambda>`.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
climate:
|
||||
- protocol: hOn
|
||||
- protocol: hon
|
||||
on_alarm_start:
|
||||
then:
|
||||
- logger.log:
|
||||
@ -158,12 +158,12 @@ This automation will be triggered when a new alarm is activated by AC. The error
|
||||
``on_alarm_end`` Trigger
|
||||
************************
|
||||
|
||||
This automation will be triggered when a previously activated alarm is deactivated by AC. The error code of the alarm will be given in the variable ``code`` (``uint8_t``), error message in the variable ``message`` (``const char *``). Those variables can be used in :ref:`lambdas <config-lambda>`
|
||||
This automation will be triggered when a previously activated alarm is deactivated by AC. The error code of the alarm will be given in the variable ``code`` (``uint8_t``), error message in the variable ``message`` (``const char *``). Those variables can be used in :ref:`lambdas <config-lambda>`.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
climate:
|
||||
- protocol: hOn
|
||||
- protocol: hon
|
||||
on_alarm_end:
|
||||
then:
|
||||
- logger.log:
|
||||
@ -176,13 +176,13 @@ This automation will be triggered when a previously activated alarm is deactivat
|
||||
``on_status_message`` Trigger
|
||||
*****************************
|
||||
|
||||
This automation will be triggered when component receives new status packet from AC. Raw message binary (without header and checksum) will be provided in the variable ``data`` (``const char *``), message length in the variable ``data_size`` (``uint8_t``). Those variables can be used in :ref:`lambdas <config-lambda>`
|
||||
This automation will be triggered when component receives new status packet from AC. Raw message binary (without header and checksum) will be provided in the variable ``data`` (``const char *``), message length in the variable ``data_size`` (``uint8_t``). Those variables can be used in :ref:`lambdas <config-lambda>`.
|
||||
This trigger can be used to support some features that unique for the model and not supported by others.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
climate:
|
||||
- protocol: hOn
|
||||
- protocol: hon
|
||||
on_status_message:
|
||||
then:
|
||||
- logger.log:
|
||||
@ -226,7 +226,7 @@ This action toggles AC power
|
||||
``climate.haier.display_on`` Action
|
||||
***********************************
|
||||
|
||||
This action turns the AC display on
|
||||
This action turns the AC display on.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -237,7 +237,7 @@ This action turns the AC display on
|
||||
``climate.haier.display_off`` Action
|
||||
************************************
|
||||
|
||||
This action turns the AC display off
|
||||
This action turns the AC display off.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -248,7 +248,7 @@ This action turns the AC display off
|
||||
``climate.haier.health_on`` Action
|
||||
**********************************
|
||||
|
||||
Turn on health mode (`UV light sterilization <https://www.haierhvac.eu/en/node/1809>`__)
|
||||
Turn on health mode (`UV light sterilization <https://www.haierhvac.eu/en/node/1809>`__).
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -259,7 +259,7 @@ Turn on health mode (`UV light sterilization <https://www.haierhvac.eu/en/node/1
|
||||
``climate.haier.health_off`` Action
|
||||
***********************************
|
||||
|
||||
Turn off health mode
|
||||
Turn off health mode.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -270,7 +270,7 @@ Turn off health mode
|
||||
``climate.haier.beeper_on`` Action
|
||||
**********************************
|
||||
|
||||
(supported only by hOn) This action enables beep feedback on every command sent to AC
|
||||
(supported only by hOn) This action enables beep feedback on every command sent to AC.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -281,7 +281,7 @@ Turn off health mode
|
||||
``climate.haier.beeper_off`` Action
|
||||
***********************************
|
||||
|
||||
(supported only by hOn) This action disables beep feedback on every command sent to AC (keep in mind that this will not work for IR remote commands)
|
||||
(supported only by hOn) This action disables beep feedback on every command sent to AC (keep in mind that this will not work for IR remote commands).
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -305,7 +305,7 @@ Turn off health mode
|
||||
``climate.haier.set_horizontal_airflow`` Action
|
||||
***********************************************
|
||||
|
||||
(supported only by hOn) Set direction for horizontal airflow if the horizontal swing is disabled. Possible values: Max_Left, Left, Center, Right, Max_Right.
|
||||
(supported only by hOn) Set direction for horizontal airflow if the horizontal swing is disabled. Possible values: ``Max_Left``, ``Left``, ``Center``, ``Right``, ``Max_Right``.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -318,7 +318,7 @@ Turn off health mode
|
||||
``climate.haier.start_self_cleaning`` Action
|
||||
********************************************
|
||||
|
||||
(supported only by hOn) Start `self-cleaning <https://www.haier.com/in/blogs/beat-the-summer-heat-with-haier-self-cleaning-ac.shtml>`__
|
||||
(supported only by hOn) Start `self-cleaning <https://www.haier.com/in/blogs/beat-the-summer-heat-with-haier-self-cleaning-ac.shtml>`__.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -329,7 +329,7 @@ Turn off health mode
|
||||
``climate.haier.start_steri_cleaning`` Action
|
||||
*********************************************
|
||||
|
||||
(supported only by hOn) Start 56°C steri-cleaning
|
||||
(supported only by hOn) Start 56°C steri-cleaning.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user