mirror of
https://github.com/esphome/esphome-docs.git
synced 2025-01-12 20:10:50 +01:00
add whirlpool climate (#552)
This commit is contained in:
parent
b3fb241b4f
commit
1b725a2500
@ -15,31 +15,33 @@ as your remote unit would do.
|
||||
There is a growing list of compatible units. If your unit is not listed below you can fill a feature
|
||||
request so it will be added (see FAQ).
|
||||
|
||||
+------------------------+---------------------+----------------------+
|
||||
| Name | Platform name | Supports receiver |
|
||||
| | | +
|
||||
+========================+=====================+======================+
|
||||
| Coolix | ``coolix`` | yes |
|
||||
+------------------------+---------------------+----------------------+
|
||||
| Daikin | ``daikin`` | yes |
|
||||
+------------------------+---------------------+----------------------+
|
||||
| Fujitsu General | ``fujitsu_general`` | no |
|
||||
+------------------------+---------------------+----------------------+
|
||||
| Mitsubishi | ``mitsubishi`` | no |
|
||||
+------------------------+---------------------+----------------------+
|
||||
| TCL112, Fuego | ``tcl112`` | yes |
|
||||
+------------------------+---------------------+----------------------+
|
||||
| Yashima | ``yashima`` | no |
|
||||
+------------------------+---------------------+----------------------+
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Name | Platform name | Supports receiver | |
|
||||
| | | | |
|
||||
+========================+=====================+======================+====================================+
|
||||
| Coolix | ``coolix`` | yes | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Daikin | ``daikin`` | yes | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Fujitsu General | ``fujitsu_general`` | | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Mitsubishi | ``mitsubishi`` | | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| TCL112, Fuego | ``tcl112`` | yes | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Yashima | ``yashima`` | | |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
| Whirlpool | ``whirlpool`` | yes | :ref:`more info<model_whirlpool>` |
|
||||
+------------------------+---------------------+----------------------+------------------------------------+
|
||||
|
||||
This component requires that you have setup a :doc:`/components/remote_transmitter`.
|
||||
|
||||
Due to the unidirectional nature of IR remote controllers, this component cannot determine the
|
||||
actual state of the device, and will assume the state of the device is the latest state requested.
|
||||
|
||||
However, when receiver is supported, you can optionally you can add a
|
||||
:doc:`/components/remote_receiver` component so the climate state will be tracked when it is operated
|
||||
with the original remote controller unit.
|
||||
However, when receiver is supported, you can optionally add a :doc:`/components/remote_receiver`
|
||||
component so the climate state will be tracked when it is operated with the original remote
|
||||
controller unit.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -94,13 +96,27 @@ IR receiver.
|
||||
number: GPIO14
|
||||
inverted: True
|
||||
mode: INPUT_PULLUP
|
||||
tolerance: 55% # high 55% tolerance is recommended for some remote control units
|
||||
# high 55% tolerance is recommended for some remote control units
|
||||
tolerance: 55%
|
||||
|
||||
climate:
|
||||
- platform: coolix
|
||||
name: "Living Room AC"
|
||||
receiver_id: rcvr
|
||||
|
||||
.. _model_whirlpool:
|
||||
|
||||
Whirlpool
|
||||
---------
|
||||
|
||||
Additional configuration is available for this model
|
||||
|
||||
- **model** (*Optional*, string): There are two valid models
|
||||
|
||||
* ``MODEL_DG11J1_3A``: Temperature range is from 18 to 32 (default)
|
||||
* ``MODEL_DG11J1_91``: Temperature range is from 16 to 30
|
||||
|
||||
|
||||
See Also
|
||||
--------
|
||||
|
||||
@ -112,4 +128,5 @@ See Also
|
||||
:apiref:`mitsubishi.h <mitsubishi/mitsubishi.h>`,
|
||||
:apiref:`tcl112.h <tcl112/tcl112.h>`,
|
||||
:apiref:`yashima.h <yashima/yashima.h>`
|
||||
:apiref:`whirlpool.h <whirlpool/whirlpool.h>`
|
||||
- :ghedit:`Edit`
|
||||
|
Loading…
Reference in New Issue