mirror of
https://github.com/esphome/esphome-docs.git
synced 2024-09-29 04:27:32 +02:00
TCS34725 automatic integration times (#1951)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
This commit is contained in:
parent
dbddc09b34
commit
306f5f55e8
@ -60,9 +60,10 @@ Configuration variables:
|
|||||||
- **illuminance** (*Optional*): Get the total illuminance of the sensor in lx.
|
- **illuminance** (*Optional*): Get the total illuminance of the sensor in lx.
|
||||||
- **color_temperature** (*Optional*): Get the calculated color temperature of the light in Kelvin.
|
- **color_temperature** (*Optional*): Get the calculated color temperature of the light in Kelvin.
|
||||||
- **gain** (*Optional*): Set the gain for the internal ADCs to work better in certain low-light conditions. Valid
|
- **gain** (*Optional*): Set the gain for the internal ADCs to work better in certain low-light conditions. Valid
|
||||||
values are ``1x`` (default), ``4x``, ``16x``, ``60x`` (highest gain).
|
values are ``1x`` (default), ``4x``, ``16x``, ``60x`` (highest gain). Will be overwritten if auto integration time
|
||||||
|
is used
|
||||||
- **integration_time** (*Optional*): The amount of time the light sensor is exposed. Valid values are
|
- **integration_time** (*Optional*): The amount of time the light sensor is exposed. Valid values are
|
||||||
``2.4ms`` (default), ``24ms``, ``50ms``, ``101ms``, ``120ms``, ``154ms``, ``180ms``, ``199ms``,
|
``auto`` (default), ``2.4ms``, ``24ms``, ``50ms``, ``101ms``, ``120ms``, ``154ms``, ``180ms``, ``199ms``,
|
||||||
``240ms``, ``300ms``, ``360ms``, ``401ms``, ``420ms``, ``480ms``, ``499ms``, ``540ms``, ``600ms``, ``614ms``.
|
``240ms``, ``300ms``, ``360ms``, ``401ms``, ``420ms``, ``480ms``, ``499ms``, ``540ms``, ``600ms``, ``614ms``.
|
||||||
- **glass_attenuation_factor** (*Optional*): The attenuation factor of glass if it's behind some glass facia.
|
- **glass_attenuation_factor** (*Optional*): The attenuation factor of glass if it's behind some glass facia.
|
||||||
Default is ``1.0`` means ``100%`` transmissivity. ``2`` means ``50%`` transmissivity etc.
|
Default is ``1.0`` means ``100%`` transmissivity. ``2`` means ``50%`` transmissivity etc.
|
||||||
@ -70,6 +71,23 @@ Configuration variables:
|
|||||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
||||||
sensor. Defaults to ``60s``.
|
sensor. Defaults to ``60s``.
|
||||||
|
|
||||||
|
For many applications, you can use AUTO timing or leave integration time empty to have the ESP select a suitable gain
|
||||||
|
setting based on the previous measurement. If light levels change dramatically this may cause the next reading to saturate,
|
||||||
|
after which the gain will adjust down and subsequent readings will be in range.
|
||||||
|
If auto is used in a dynamic environment an update rate of 1 second is best. Filters can be used to throttle the output and
|
||||||
|
prevent updates of marginal changes like:
|
||||||
|
|
||||||
|
.. code-block:: yaml
|
||||||
|
|
||||||
|
illuminance:
|
||||||
|
name: "TCS34725 Illuminance"
|
||||||
|
filters:
|
||||||
|
- or:
|
||||||
|
- delta: 50
|
||||||
|
- throttle: 60sec
|
||||||
|
|
||||||
|
When using integration times lower than 154ms the accuracy of the sensor drops with no further gain in possible light
|
||||||
|
accumulation. Use faster timings only if fast readout is necessary with stable light conditions recommended.
|
||||||
|
|
||||||