Improve SGP30 humidity compensation documentation (#3556)

* Improve SGP30 compensation documentation

* Use must instead of should, fix celsius spelling
This commit is contained in:
ave 2024-06-04 15:25:34 +02:00 committed by GitHub
parent 992b09a145
commit 39abfa64e3
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

View File

@ -72,12 +72,12 @@ Advanced:
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
- All other options from :ref:`Sensor <config-sensor>`.
- **compensation** (*Optional*): The block containing sensors used for compensation.
- **compensation** (*Optional*): The block containing sensors used for compensation. Both values must be supplied in order to be able to generate the absolute humidity to be reported to the sensor.
- **temperature_source** (*Optional*, :ref:`config-id`): Give an external temperature sensor ID
here. This can improve the sensor's internal calculations.
here. The data must be in Celsius. This can improve the sensor's internal calculations.
- **humidity_source** (*Optional*, :ref:`config-id`): Give an external humidity sensor ID
- **humidity_source** (*Optional*, :ref:`config-id`): Give an external relative humidity sensor ID
here. This can improve the sensor's internal calculations.
.. _sgp30-calibrating: