Merge pull request #2371 from rlowens/patch-5

Add example workaround for static uniqueid
This commit is contained in:
H. Árkosi Róbert 2022-11-28 11:25:08 +01:00 committed by GitHub
commit 46ad9781dd
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 20 additions and 0 deletions

View File

@ -23,6 +23,26 @@ measured in decibel-milliwatts (dBm). These values are always negative and the c
name: "WiFi Signal Sensor"
update_interval: 60s
To additionally display signal strength in percentage use the :ref:`copy-sensor` (it's not possible to add the same sensor twice, because it has a static ``uniqueid`` reported to Home Assistant):
.. code-block:: yaml
# Example configuration entry with 2 sensors and filter
sensor:
- platform: wifi_signal # Reports the WiFi signal strength/RSSI in dB
name: "WiFi Signal dB"
id: wifi_signal_db
update_interval: 60s
entity_category: "diagnostic"
- platform: copy # Reports the WiFi signal strength in %
source_id: wifi_signal_db
name: "WiFi Signal Percent"
filters:
- lambda: return min(max(2 * (x + 100.0), 0.0), 100.0);
unit_of_measurement: "Signal %"
entity_category: "diagnostic"
Configuration variables:
------------------------