From 4a25659b0bf7c6a3b66dee86083d0ec4d35e5eee Mon Sep 17 00:00:00 2001 From: Alex <33060660+redwngsrul@users.noreply.github.com> Date: Mon, 13 Sep 2021 16:19:51 -0400 Subject: [PATCH] Added current calibration section for gain_pga = 4X (#1384) For the SCT024 200A/100mA CT --- components/sensor/atm90e32.rst | 3 +++ 1 file changed, 3 insertions(+) diff --git a/components/sensor/atm90e32.rst b/components/sensor/atm90e32.rst index 2d9d4c27e..07509a624 100644 --- a/components/sensor/atm90e32.rst +++ b/components/sensor/atm90e32.rst @@ -125,6 +125,9 @@ It is possible that the two identical CT current sensors will have different small. The current calibration can be done once and used on all sensors or repeated for each one. +Here are common current calibration values for the **Split Single Phase Energy Meter** when **gain_pga** is set to ``4X``: + - 200A/100mA SCT-024: 12597 + Here are common current calibration values for the **Split Single Phase Energy Meter** when **gain_pga** is set to ``2X``: - 20A/25mA SCT-006: 10170 - 100A/50mA SCT-013-000: 25498