Examples of Daly BMS control using uart.write (#2584)
* Update daly_bms.rst Add a couple of examples of Daly BMS control using uart.write * Examples of Daly BMS control using uart.write fixed lint errors * Examples of Daly BMS control using uart.write probably fixed lint errors * Fixed every boot up battery level setup
This commit is contained in:
parent
a34f2c8679
commit
5d870401ff
@ -228,6 +228,136 @@ Configuration variables:
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
||||
|
||||
|
||||
Control BMS
|
||||
-----------
|
||||
At this moment Daly sensor platform don't suppport controlling you BMS, but you can make some stuff using uart.write
|
||||
|
||||
First you need to setup binary sensors for charging and disharging MOS
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
|
||||
binary_sensor:
|
||||
- platform: daly_bms
|
||||
charging_mos_enabled:
|
||||
name: "Daly Charging MOS"
|
||||
id: bin_daly_chg_mos # binary MOS sensor must have ID to use with switch
|
||||
internal: True # but you can make it internal to avoid duplication
|
||||
discharging_mos_enabled:
|
||||
name: "Daly Discharging MOS"
|
||||
id: bin_daly_dischg_mos # binary MOS sensor must have ID to use with switch
|
||||
internal: True # but you can make it internal to avoid duplication
|
||||
|
||||
Then you can add switches
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
|
||||
switch:
|
||||
- platform: template
|
||||
name: "Daly Charging MOS"
|
||||
lambda: |-
|
||||
if (id(bin_daly_chg_mos).state) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
}
|
||||
turn_on_action:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0xDA, 0x08, 0x01, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xC8]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set charge MOS on"
|
||||
turn_off_action:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0xDA, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xC7]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set charge MOS off"
|
||||
|
||||
- platform: template
|
||||
name: "Daly Discharging MOS"
|
||||
lambda: |-
|
||||
if (id(bin_daly_dischg_mos).state) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
}
|
||||
turn_on_action:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0xD9, 0x08, 0x01, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xC7]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set discharge MOS on"
|
||||
turn_off_action:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0xD9, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xC6]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set discharge MOS off"
|
||||
|
||||
|
||||
Also you can add select to change battery level
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
|
||||
select:
|
||||
- platform: template
|
||||
name: "Daly Battery Level setup"
|
||||
optimistic: True
|
||||
options:
|
||||
- 100%
|
||||
- 75%
|
||||
- 50%
|
||||
- 25%
|
||||
- 0%
|
||||
initial_option: 100%
|
||||
set_action:
|
||||
then:
|
||||
- if:
|
||||
condition:
|
||||
lambda: 'return x == "100%";'
|
||||
then:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0x21, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x03, 0xE8, 0xF9]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set SOC to 100%"
|
||||
else:
|
||||
- if:
|
||||
condition:
|
||||
lambda: 'return x == "75%";'
|
||||
then:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0x21, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x02, 0xEE, 0xFE]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set SOC to 75%"
|
||||
else:
|
||||
- if:
|
||||
condition:
|
||||
lambda: 'return x == "50%";'
|
||||
then:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0x21, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x01, 0xF4, 0x03]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set SOC to 50%"
|
||||
else:
|
||||
- if:
|
||||
condition:
|
||||
lambda: 'return x == "25%";'
|
||||
then:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0x21, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xFA, 0x08]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set SOC to 25%"
|
||||
else:
|
||||
- if:
|
||||
condition:
|
||||
lambda: 'return x == "0%";'
|
||||
then:
|
||||
- uart.write:
|
||||
data: [0xA5, 0x40, 0x21, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x0E]
|
||||
- logger.log:
|
||||
format: "Send cmd to Daly: Set SOC to 0%"
|
||||
|
||||
|
||||