BH1750 dynamically calculate options (#1915)
This commit is contained in:
parent
d948eb737a
commit
5fa975f029
|
@ -28,15 +28,8 @@ your configuration for this sensor to work.
|
|||
- platform: bh1750
|
||||
name: "BH1750 Illuminance"
|
||||
address: 0x23
|
||||
measurement_duration: 69
|
||||
update_interval: 60s
|
||||
|
||||
By default the **measurement_duration** is set to ``69`` which will result into measurements up
|
||||
to 54612.5 lx for this sensor. For low-light situations consider to choose a higher
|
||||
measurement_duration up to ``254`` which will result in a maximum measurement range up to 14835 lx.
|
||||
For sunny scenes (for example outdoors with sunlight) use lower values down to ``31`` which will
|
||||
give you the maximum measurement range up to 121556 lx.
|
||||
|
||||
Configuration variables:
|
||||
------------------------
|
||||
|
||||
|
@ -44,10 +37,6 @@ Configuration variables:
|
|||
- **address** (*Optional*, int): Manually specify the I²C address of the sensor.
|
||||
Defaults to ``0x23`` (address if address pin is pulled low). If the address pin is pulled high,
|
||||
the address is ``0x5C``.
|
||||
- **measurement_duration** (*Optional*, int): Manually specify the measurement duration between ``31``
|
||||
and ``254``. Defaults to ``69``.
|
||||
- **resolution** (*Optional*, string): The resolution of the sensor in lx. One of ``4.0``,
|
||||
``1.0``, ``0.5``. Defaults to ``0.5`` (the maximum resolution).
|
||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
||||
sensor. Defaults to ``60s``.
|
||||
- **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for code
|
||||
|
|
Loading…