@ -106,7 +106,10 @@ Configuration variables:
- **protocol** (*Optional*, string): Defines protocol of communication with AC. Possible values: hon or smartair2. Default value is smartair2.
- **name** (**Required**, string): The name of the climate device.
- **wifi_signal** (*Optional*, boolean): If true - send wifi signal level to AC.
- **answer_timeout** (*Optional*, :ref:`config-time`): Responce timeout. Default value is 150ms.
- **answer_timeout** (*Optional*, :ref:`config-time`): Responce timeout. Default value is 200ms.
- **alternative_swing_control** (*Optional*, boolean): (supported by smartAir2 only) If true - use alternative values to control swing mode. Use only if the original control method is not working for your AC.
- **control_packet_size** (*Optional*, int): (supported only by hOn) Define the size of the control packet. Can help with some newer models of ACs that use bigger packets. Default value: 10.
- **control_method** (*Optional*, list): (supported only by hOn) Defines control method (should be supported by AC). Supported values: MONITOR_ONLY - no control, just monitor status, SET_GROUP_PARAMETERS - set all AC parameters with one command (default method), SET_SINGLE_PARAMETER - set each parameter individually (this method is supported by some new ceiling ACs like AD71S2SM3FA)
- **display** (*Optional*, boolean): Can be used to set AC display off.
- **beeper** (*Optional*, boolean): Can be used to disable beeping on commands from AC. Supported only by hOn protocol.
- **outdoor_temperature** (*Optional*): Temperature sensor for outdoor temperature. Supported only by hOn protocol.