@ -5,7 +5,7 @@ Pulse Meter Sensor
|
||||
:description: Instructions for setting up pulse meter sensors.
|
||||
:image: pulse.png
|
||||
|
||||
The pulse meter sensor allows you to count the number and frequency of pulses on any pin. It is intended to be a drop-in replacement
|
||||
The pulse meter sensor allows you to count the number and frequency of pulses on any pin. It is intended to be a drop-in replacement
|
||||
for :doc:`integration sensor </components/sensor/pulse_counter>`, but offering better resolution.
|
||||
It measures the time between rising edges on a pin, for each pulse it outputs the frequency in pulses/min.
|
||||
|
||||
@ -35,7 +35,7 @@ Converting units
|
||||
|
||||
The sensor defaults to units of “pulses/min”. You can change this by using :ref:`sensor-filters`.
|
||||
For example, if you’re using the pulse meter with a photodiode to
|
||||
count the light pulses on a power meter that outputs 1000 pulses per kWh,
|
||||
count the light pulses on a power meter that outputs 1000 pulses per kWh,
|
||||
you can use the following to output instantaneous usage in kW:
|
||||
|
||||
.. code-block:: yaml
|
||||
@ -52,9 +52,9 @@ you can use the following to output instantaneous usage in kW:
|
||||
Counting total pulses
|
||||
---------------------
|
||||
|
||||
When the total sensor is configured, pulse_meter also reports the total
|
||||
number of pulses measured. When used on a power meter, this can be used to
|
||||
measure the total consumed energy in kWh.
|
||||
When the total sensor is configured, pulse_meter also reports the total
|
||||
number of pulses measured. When used on a power meter, this can be used to
|
||||
measure the total consumed energy in kWh.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
@ -73,6 +73,27 @@ measure the total consumed energy in kWh.
|
||||
filters:
|
||||
- multiply: 0.001
|
||||
|
||||
(Re)Setting the total pulse count
|
||||
---------------------------------
|
||||
|
||||
Using this action, you are able to reset/set the total pulse count. This can be useful
|
||||
if you would like the ``total`` sensor to match what you see on your meter you are
|
||||
trying to match.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- pulse_meter.set_total_pulses:
|
||||
id: pulse_meter_id
|
||||
value: 12345
|
||||
|
||||
.. note::
|
||||
|
||||
This value is the raw count of pulses, and not the value you see after the filters
|
||||