Fixed attenuation values (#3868)
According to the docs 12db is not allowed. https://docs.espressif.com/projects/esp-idf/en/v4.4.7/esp32/api-reference/peripherals/adc.html#_CPPv425adc1_config_channel_atten14adc1_channel_t11adc_atten_t
This commit is contained in:
parent
102aafa9b1
commit
89d087197f
@ -62,7 +62,7 @@ ESP32 Attenuation
|
||||
-----------------
|
||||
|
||||
On the ESP32 the voltage measured with the ADC caps out at ~1.1V by default as the sensing range (attenuation of the ADC) is set to ``0db`` by default.
|
||||
Measuring higher voltages requires setting ``attenuation`` to one of the following values: ``0db``, ``2.5db``, ``6db``, ``12db``.
|
||||
Measuring higher voltages requires setting ``attenuation`` to one of the following values: ``0db``, ``2.5db``, ``6db``, ``11db``.
|
||||
There's more information `at the manufacturer's website <https://docs.espressif.com/projects/esp-idf/en/v4.4.7/esp32/api-reference/peripherals/adc.html#_CPPv425adc1_config_channel_atten14adc1_channel_t11adc_atten_t>`__.
|
||||
|
||||
To simplify this, we provide the setting ``attenuation: auto`` for an automatic/seamless transition among scales. `Our implementation
|
||||
|