Add support for ZHLT01 heatpump IR protocol (#2199)

Co-authored-by: Chris Feenstra <chris@cfeenstra.nl>
This commit is contained in:
Chris Feenstra 2022-10-12 04:30:00 +02:00 committed by GitHub
parent af9abec4f4
commit 89fad3a06c
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 3 additions and 1 deletions

View File

@ -102,7 +102,7 @@ This platform utilises the library's generic one-size-fits-all API, which might
Additional configuration must be specified for this platform:
- **protocol** (**Required**, string): Choose one of Arduino-HeatpumpIR's supported protcols: ``aux``, ``ballu``, ``carrier_mca``, ``carrier_nqv``, ``daikin_arc417``, ``daikin_arc480``, ``daikin``, ``electroluxyal``, ``fuego``, ``fujitsu_awyz``, ``gree``, ``greeya``, ``greeyac``, ``greeyan``, ``hisense_aud``, ``hitachi``, ``hyundai``, ``ivt``, ``midea``, ``mitsubishi_fa``, ``mitsubishi_fd``, ``mitsubishi_fe``, ``mitsubishi_heavy_fdtc``, ``mitsubishi_heavy_zj``, ``mitsubishi_heavy_zm``, ``mitsubishi_heavy_zmp``, ``mitsubishi_heavy_kj``, ``mitsubishi_msc``, ``mitsubishi_msy``, ``mitsubishi_sez``, ``panasonic_ckp``, ``panasonic_dke``, ``panasonic_jke``, ``panasonic_lke``, ``panasonic_nke``, ``samsung_aqv``, ``samsung_fjm``, ``sharp``, ``toshiba_daiseikai``, ``toshiba``
- **protocol** (**Required**, string): Choose one of Arduino-HeatpumpIR's supported protcols: ``aux``, ``ballu``, ``carrier_mca``, ``carrier_nqv``, ``daikin_arc417``, ``daikin_arc480``, ``daikin``, ``electroluxyal``, ``fuego``, ``fujitsu_awyz``, ``gree``, ``greeya``, ``greeyac``, ``greeyan``, ``hisense_aud``, ``hitachi``, ``hyundai``, ``ivt``, ``midea``, ``mitsubishi_fa``, ``mitsubishi_fd``, ``mitsubishi_fe``, ``mitsubishi_heavy_fdtc``, ``mitsubishi_heavy_zj``, ``mitsubishi_heavy_zm``, ``mitsubishi_heavy_zmp``, ``mitsubishi_heavy_kj``, ``mitsubishi_msc``, ``mitsubishi_msy``, ``mitsubishi_sez``, ``panasonic_ckp``, ``panasonic_dke``, ``panasonic_jke``, ``panasonic_lke``, ``panasonic_nke``, ``samsung_aqv``, ``samsung_fjm``, ``sharp``, ``toshiba_daiseikai``, ``toshiba``, ``zhlt01``
- **horizontal_default** (**Required**, string): What to default to when the AC unit's horizontal direction is *not* set to swing. Options are: ``left``, ``mleft``, ``middle``, ``mright``, ``right``, ``auto``
- **vertical_default** (**Required**, string): What to default to when the AC unit's vertical direction is *not* set to swing. Options are: ``down``, ``mdown``, ``middle``, ``mup``, ``up``, ``auto``
- **max_temperature** (**Required**, float): The maximum temperature that the AC unit supports being set to.
@ -120,6 +120,8 @@ Additional configuration must be specified for this platform:
internal temperature sensor; a value of 2 minutes seems to work well. See :doc:`/components/sensor/index`
for more information.
- The ``zhlt01`` protocol supports multiple AC brands: Eurom, Chigo, Tristar, Tecnomaster, Elgin, Geant, Tekno, Topair, Proma, Sumikura, JBS, Turbo Air, Nakatomy, Celestial Air, Ager, Blueway, Airlux, etc.
.. _ir-receiver_id:
Using a Receiver