@ -8,22 +8,56 @@ VBus Component
|
|||
|
||||
The ``VBus`` Component provides status reading connectivity to solar heat energy collector controllers using VBus
|
||||
protocol. These devices are mainly produced by Resol, often also found under different brand names like Viessmann,
|
||||
Kioto, Wagner etc. The component currently supports natively Resol DeltaSol C, DeltaSol CS2, DeltaSol CS Plus, and DeltaSol BS Plus
|
||||
Kioto, Wagner etc. The component currently supports natively the models in the table below
|
||||
but any device can be added via lambda by knowing `its packet structure <https://danielwippermann.github.io/resol-vbus>`__.
|
||||
|
||||
.. figure:: ../images/resol_deltasol_bs_plus.jpg
|
||||
:align: center
|
||||
|
||||
Supported Models
|
||||
----------------
|
||||
|
||||
The following table shows the currently supported models of Vbus devices.
|
||||
|
||||
.. csv-table:: Supported Models
|
||||
:header: "Name", "Config Value", "Hex Address", "Notes"
|
||||
|
||||
"DeltaSol BS Plus","deltasol_bs_plus","4221"
|
||||
"DeltaSol BS 2009","deltasol_bs_2009","427B"
|
||||
"Dux H3214","deltasol_bs_2009","427B", "Pump 2 unsupported"
|
||||
"DeltaSol C","deltasol_c","4212"
|
||||
"DeltaSol CS2","deltasol_cs2","1121"
|
||||
"DeltaSol CS2 Plus","deltasol_cs2_plus","2211"
|
||||
|
||||
The ``Config Value`` should be used for the ``model`` parameter in your ``sensor`` and ``binary_sensor`` entries.
|
||||
|
||||
The ``Hex Address`` field is the value sent by a device in the ``from`` field of a message. To identify an unknown
|
||||
model, set the logger level to ``VERBOSE`` and look for lines like this in the log output:
|
||||
|
||||
``[10:53:48][V][vbus:068]: P1 C0500 427b->0000: 0000 0000 (0)``
|
||||
|
||||
The value before the ``->`` symbol is the device source address. If it matches one of the entries in the table above
|
||||
then that model should work with your unit.
|
||||
|
||||
|
||||
Hardware Connection
|
||||
-------------------
|
||||
|
||||
The device must be connected via a :doc:`UART bus </components/uart>` supporting the receiving line only. The UART bus
|
||||
must be configured at the same speed of the module which is by default 9600bps. The controller outputs data every second.
|
||||
|
||||
To connect to this and read data from the bus a level shifting is needed as the voltage is around 8V (direct connection
|
||||
would damage the MCU). Although this is a symmetric connection supporting long wires, for our read-only purposes it's
|
||||
enough to adapt the level appropriately to 3.3V using a circuit like below:
|
||||
would damage the MCU). For our read-only purposes it's
|
||||
sufficient to adapt the level appropriately to 3.3V using a circuit like below:
|
||||
|
||||
.. figure:: ../images/resol_vbus_adapter_schematic.png
|
||||
:align: center
|
||||
|
||||
An electrically isolated version using an opto-coupler:
|
||||
|
||||
.. figure:: images/vbus_serial_optocoupler.png
|
||||
:align: center
|
||||
|
||||
Another approach, with PCB design ready to be manufactured `can be found here <https://github.com/FatBeard/vbus-arduino-library/tree/master/pcb>`__.
|
||||
|
||||
.. warning::
|
||||
|
@ -62,7 +96,7 @@ Configuration variables:
|
|||
|
||||
.. note::
|
||||
|
||||
Functionality of the sensors depends on the type of the device and the the scheme arrangement of the hydraulic
|
||||
Functionality of the sensors depends on the type of the device and the scheme arrangement of the hydraulic
|
||||
system it controls. The actual arrangement number set up can be determined from the settings of the device. Please
|
||||
check the user manual and assess your arrangement to determine the functionality of each sensor and name them
|
||||
accordingly.
|
||||
|
@ -103,12 +137,11 @@ Sensor
|
|||
|
||||
Configuration variables:
|
||||
|
||||
- **model** (**Required**): Specify the model of the connected controller. Currently supported models are: ``deltasol_bs_plus``, ``deltasol_c``, ``deltasol_cs2``, ``deltasol_cs_plus``.
|
||||
|
||||
- **model** (**Required**): Specify the model of the connected controller. Choose one of the config values listed in the table of supported models above.
|
||||
|
||||
Supported sensors:
|
||||
|
||||
- for **deltasol_bs_plus**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``, ``version``.
|
||||
- for **deltasol_bs_plus** and **deltasol_bs_2009**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``, ``version``.
|
||||
- for **deltasol_c**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``.
|
||||
- for **deltasol_cs2**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``pump_speed``, ``operating_hours``, ``heat_quantity``, ``version``.
|
||||
- for **deltasol_cs_plus**: ``temperature_1``, ``temperature_2``, ``temperature_3``, ``temperature_4``, ``temperature_5``, ``pump_speed_1``, ``pump_speed_2``, ``operating_hours_1``, ``operating_hours_2``, ``heat_quantity``, ``time``, ``version``, ``flow_rate``.
|
||||
|
@ -160,16 +193,16 @@ Binary Sensor
|
|||
|
||||
Configuration variables:
|
||||
|
||||
- **model** (**Required**): Specify the model of the connected controller. Currently supported models are: ``deltasol_bs_plus``, ``deltasol_c``, ``deltasol_cs2``, ``deltasol_cs_plus``.
|
||||
- **model** (**Required**): Specify the model of the connected controller. Choose one of the config values listed in the table of supported models above.
|
||||
|
||||
Supported sensors:
|
||||
|
||||
- for **deltasol_bs_plus**: ``relay1``, ``relay2``, ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``, ``collector_max``, ``collector_min``, ``collector_frost``, ``tube_collector``, ``recooling``, ``hqm``.
|
||||
- for **deltasol_bs_2009**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``, ``frost_protection_active``.
|
||||
- for **deltasol_c**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
||||
- for **deltasol_cs2**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
||||
- for **deltasol_cs_plus**: ``sensor1_error``, ``sensor2_error``, ``sensor3_error``, ``sensor4_error``.
|
||||
|
||||
|
||||
All binary sensors are *Optional* and support all other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
||||
|
||||
|
||||
|
|