@ -65,6 +65,17 @@ Configuration variables:
|
||||
*altitude_compensation* is ignored if *ambient_pressure_compensation*
|
||||
is set.
|
||||
|
||||
|
||||
- **measurement_mode** (*Optional*): Set measurement mode for scd4x.
|
||||
|
||||
- **periodic** : The sensor takes a new measurement every 5 seconds. This is the default mode.
|
||||
- **low_power_periodic**: The sensor takes a new measurement every 30 seconds. Make sure ``update_interval`` is at least 30 seconds.
|
||||
- **single_shot**: A measurement is started in every update interval. A measurement takes 5 seconds. This mode is only available on scd41 and useful if low power consumption is required.
|
||||
The automatic self-calibration is optimized for single shot measurements performed every 5 minutes.
|
||||
To reduce noise levels, you can can perform several single shot measurements in a row and average the output values using a :ref:`sensor-filters`.
|
||||
- **single_shot_rht_only**: A measurement is started in every update interval. A measurement takes 50 ms. Only humidity and temperature is measured. CO2 is reported as 0 ppm. This mode is only available on scd41 and useful if low power consumption is required.
|
||||
|
||||
|
||||
- **ambient_pressure_compensation_source** (*Optional*, :ref:`config-id`): Set an external pressure sensor ID used for ambient pressure compensation.
|
||||
The pressure sensor must report pressure in hPa. the correction is applied before updating the state of the co2 sensor.
|
||||
|
||||
@ -74,6 +85,50 @@ Configuration variables:
|
||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
||||
sensor. Defaults to ``60s``.
|
||||
|
||||
Actions:
|
||||
--------
|
||||
|
||||
.. _perform_forced_calibration_action:
|
||||
|
||||
``_perform_forced_calibration_action`` Action
|
||||
---------------------------------------------
|
||||
|
||||
This :ref:`action <config-action>` manually calibrates the sensor to the provided value in ppm.
|
||||
Operate the SCD4x in the operation mode later used in normal sensor operation (periodic measurement, low power periodic measurement or single shot) for > 3 minutes in an environment with homogenous and constant CO2 concentration before performing a forced recalibration.
|
||||
As of April 2022 the average fresh air Co² concentration is 419 ppm.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- scd4x._perform_forced_calibration_action:
|
||||
value: 419 # outside average April 2022
|
||||
id: my_scd41
|
||||
|
||||
value can be a template
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- scd4x._perform_forced_calibration_action:
|
||||
value: !lambda "{ return 419 };"
|
||||
id: my_scd41
|
||||
|
||||
|
||||
.. _factory_reset_action:
|
||||
|
||||
``_factory_reset_action`` Action
|
||||
--------------------------------
|
||||
|
||||
This :ref:`action <config-action>` triggers a factory reset of the sensor. Calibration settings are restored from factory settings.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- scd4x._factory_reset_action: my_scd41
|
||||
|
||||