@ -48,6 +48,19 @@ Based on this, you can create a number as follows:
|
|||||||
max_value: 2
|
max_value: 2
|
||||||
step: 1
|
step: 1
|
||||||
|
|
||||||
|
The value for ``step`` is used as the scaling factor for the Number. All numbers in Tuya are integers, so a scaling factor is sometimes needed to convert the Tuya reported value into floating point.
|
||||||
|
|
||||||
|
For instance, assume we have a pH sensor that reads from 0.00 to 15.00 with a scaling of 0.01. By setting `step` to 0.01, on the Tuya side (not visible to the user) the number will be reported as an integer from 0 to 1500. The following configuration could be used:
|
||||||
|
|
||||||
|
.. code-block:: yaml
|
||||||
|
|
||||||
|
- platform: "tuya"
|
||||||
|
name: "pH Sensor"
|
||||||
|
number_datapoint: 106
|
||||||
|
min_value: 0.00
|
||||||
|
max_value: 15.00
|
||||||
|
step: 0.01
|
||||||
|
|
||||||
Configuration variables:
|