@ -36,6 +36,16 @@ Configuration variables:
- **reboot_timeout** (*Optional*, :ref:`time <config-time>`): The amount of time to wait before rebooting when in
safe mode. Defaults to ``5min``.
- **num_attempts** (*Optional*, int): The number of attempts to wait before entering safe mode. Defaults to ``10``.
- **on_begin** (*Optional*, :ref:`Automation<automation>`): An action to be
performed when an OTA update is started. See :ref:`ota-on_begin`.
- **on_progress** (*Optional*, :ref:`Automation<automation>`): An action to be
performed (multiple times) during an OTA update. See :ref:`ota-on_progress`.
- **on_end** (*Optional*, :ref:`Automation<automation>`): An action to be
performed after a successful OTA update. See :ref:`ota-on_end`.
- **on_error** (*Optional*, :ref:`Automation<automation>`): An action to be
performed after a failed OTA update. See :ref:`ota-on_error`.
- **on_state_change** (*Optional*, :ref:`Automation<automation>`): An action to be
performed when an OTA update state change happens. See :ref:`ota-on_state_change`.
.. note::
@ -46,6 +56,120 @@ Configuration variables:
very likely that power-cycling the ESP module is required once after
the serial upload.
OTA Automation
--------------
The OTA component provides various automations that can be used to provide feedback
during an OTA update. There are a few things to consider when making use of the
provided automation triggers:
- An OTA update blocks the main loop during its operation. This means that you
won't be able to represent state changes using components that update their
output only from within their ``loop()`` method. Explained differently: if you
try to display the OTA progress using component X, but the update only appears
after the OTA update finished, then component X cannot be used for providing
OTA update feedback.
- Make sure that your automation actions do not take too much time, to prevent
them from blocking the OTA update code for too long.
.. _ota-on_begin:
``on_begin``
************
This automation will be triggered when an OTA update is started.
.. code-block:: yaml
ota:
on_begin:
then:
- logger.log: "OTA start"
.. _ota-on_progress:
``on_progress``
***************
Using this automation, it is possible to report on the OTA update progress.
It will be triggered multiple times during the OTA update. You can get the actual
progress percentage (a value between 0 and 100) from the trigger with variable ``x``.
.. code-block:: yaml
ota:
on_progress:
then:
- logger.log:
format: "OTA progress %0.1f%%"
args: ["x"]
.. _ota-on_end:
``on_end``
**********
This automation will be triggered when an OTA update has completed sucessfully,
right before the device is rebooted.
Because the update has completed, you can safely use an automation action that
takes some time to complete. This can for example be useful if you want to flash
a LED or so, in which case a pause would be required to make the LED light up
for long enough, before the reboot turns it off.
.. code-block:: yaml
ota:
on_end:
then:
- logger.log: "OTA end"
.. _ota-on_error:
``on_error``
************
This automation will be triggered when an OTA update has failed. You can get
the internal error code with variable ``x``.
Just like for :ref:`ota-on_end`, you can safely use an automation that
takes some time to complete, because the OTA update is no longer busy.
.. code-block:: yaml
ota:
on_error:
then:
- logger.log:
format: "OTA update error %d"
args: ["x"]
.. _ota-on_state_change:
``on_state_change``
*******************
This automation will be triggered on every state change. You can get the actual
state with variable ``state``, which will contain one of values for the OTAState
enum. These values are:
- ``ota::OTA_STARTED``
- ``ota::OTA_IN_PROGRESS`` (will be called multiple times during the update)
- ``ota::OTA_COMPLETED``
- ``ota::OTA_ERROR``
.. code-block:: yaml
ota:
on_state_change:
then:
- if:
condition:
lambda: return state == ota::OTA_STARTED
then:
- logger.log: "OTA start"
Updating the password:
----------------------

View File

@ -334,6 +334,9 @@ All Triggers
- :ref:`switch.on_turn_on/off <switch-on_turn_on_off_trigger>`
- :ref:`sim800l.on_sms_received <sim800l-on_sms_received>`
- :ref:`rf_bridge.on_code_received <rf_bridge-on_code_received>`
- :ref:`ota.on_begin <ota-on_begin>` / :ref:`ota.on_progress <ota-on_progress>` /
:ref:`ota.on_end <ota-on_end>` / :ref:`ota.on_error <ota-on_error>` /
:ref:`ota.on_state_change <ota-on_state_change>`
All Actions
-----------