Atlas Scientific Peristaltic Pump
|
||||
=================================
|
||||
|
||||
.. seo::
|
||||
:description: Instructions for setting up an Atlas Scientific Peristaltic Pump in ESPHome
|
||||
:image: ezo-pmp.jpg
|
||||
:keywords: pump, peristaltic, atlas, ezo
|
||||
|
||||
The ``ezo_pmp`` component allows you to use an Atlas Scientific Peristaltic Pump with ESPHome.
|
||||
Both the EZO-PMP (`datasheet <https://files.atlas-scientific.com/EZO_PMP_Datasheet.pdf>`__)
|
||||
and EZO-PMP-L (`datasheet <https://files.atlas-scientific.com/EZO_PMP_L_Datasheet.pdf>`__) are supported.
|
||||
The :ref:`I²C Bus <i2c>` is required to be set up in your configuration for this sensor to work.
|
||||
|
||||
.. note::
|
||||
|
||||
This component will not be directly controllable in the Home Assistant front-end automatically because
|
||||
Home Assistant doesn't have support for pumps. In order to control the pump from the frontend you will need to use
|
||||
templates to offer access to the actions you need. Please see :ref:`ezo-pmp-ha-config`.
|
||||
|
||||
.. figure:: images/ezo-pmp.jpg
|
||||
:align: center
|
||||
:width: 80.0%
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
ezo_pmp:
|
||||
id: ezo_pmp
|
||||
address: 103 # Default Address for the EZO-PMP.
|
||||
update_interval: 60s
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): Specify the ID of the pump so that you can control it.
|
||||
- **address** (*Optional*, int): Specify the I²C address of the sensor. Defaults to 103.
|
||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
|
||||
sensor. Defaults to ``60s``.
|
||||
|
||||
Sensors
|
||||
-----------------------------
|
||||
|
||||
Since the EZO-PMP offers a large number of sensors and each sensor needs to be polled individually, the code has been
|
||||
optimized not to update a sensor that is not defined in the config. If you need very quick updates from the pump (under 3 seconds)
|
||||
only enable the sensors that you actually need.
|
||||
|
||||
.. _ezo_pmp-current_volume_dosed_sensor:
|
||||
|
||||
``current_volume_dosed``
|
||||
-----------------------------
|
||||
|
||||
This sensor indicates the volume (in milliliters) that has been dosed in the currently running or last ran dosing command.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
current_volume_dosed:
|
||||
id: current_volume_dosed
|
||||
name: Current Volume Dosed
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
.. _ezo_pmp-total_volume_dosed_sensor:
|
||||
|
||||
``total_volume_dosed``
|
||||
-----------------------------
|
||||
|
||||
This sensor indicates total volume (in milliliters) that has been dosed since the last time the pump was turned on. Could be a
|
||||
negative number if the pump has been run in reverse.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
total_volume_dosed:
|
||||
id: total_volume_dosed
|
||||
name: Total Volume Dosed
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
.. _ezo_pmp-absolute_total_volume_dosed_sensor:
|
||||
|
||||
``absolute_total_volume_dosed``
|
||||
-------------------------------
|
||||
|
||||
This sensor indicates the absolute total volume (in milliliters) that has been dosed since the last time the pump was turned on.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
absolute_total_volume_dosed:
|
||||
id: absolute_total_volume_dosed
|
||||
name: Absolute Total Volume Dosed
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
.. _ezo_pmp-last_volume_requested_sensor:
|
||||
|
||||
``last_volume_requested``
|
||||
-----------------------------
|
||||
|
||||
Indicates the total volume (in milliliters) that is being dosed (or was if the pump has already finished) by a dose Action. When
|
||||
using dosing actions that have a duration, the sensor will have the right calculation for total volume.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
last_volume_requested:
|
||||
id: last_volume_requested
|
||||
name: Last Volume Requested
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
.. _ezo_pmp-max_flow_rate_sensor:
|
||||
|
||||
``max_flow_rate``
|
||||
-----------------------------
|
||||
|
||||
The pump provides its own calculation of the maximum flow rate it can provide (in ml/minute). Dosing requests that exceed this rate
|
||||
will fail. When using the :ref:`Dose Continuously <ezo_pmp-dose_continuously_action>` Action, this is the volume the pump will
|
||||
dose every minute. This value will get updated after the pump is calibrated (see :ref:`ezo_pmp-set_calibration_volume_action`).
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
max_flow_rate:
|
||||
id: max_flow_rate
|
||||
name: Max Flow Rate
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
.. _ezo_pmp-pump_voltage_sensor:
|
||||
|
||||
``pump_voltage``
|
||||
-----------------------------
|
||||
|
||||
The current voltage of the power supply that powers the pump. Not to be confused with the voltage that powers the electronics on the pump.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: ezo_pmp
|
||||
pump_voltage:
|
||||
id: pump_voltage
|
||||
name: Pump Voltage
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Sensor <config-sensor>`.
|
||||
|
||||
Binary Sensors
|
||||
-----------------------------
|
||||
|
||||
.. _ezo_pmp-pump_state_binary_sensor:
|
||||
|
||||
``pump_state``
|
||||
-----------------------------
|
||||
|
||||
Indicates if the pump is currently running or not.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
binary_sensor:
|
||||
- platform: ezo_pmp
|
||||
pump_state:
|
||||
id: pump_state
|
||||
name: Pump State
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
||||
|
||||
.. _ezo_pmp-is_paused_binary_sensor:
|
||||
|
||||
``is_paused``
|
||||
-----------------------------
|
||||
|
||||
Indicates if a dosing action is currently paused.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
binary_sensor:
|
||||
- platform: ezo_pmp
|
||||
is_paused:
|
||||
id: is_paused
|
||||
name: Is Paused
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Binary Sensor <config-binary_sensor>`.
|
||||
|
||||
|
||||
Text Sensors
|
||||
-----------------------------
|
||||
|
||||
.. _ezo_pmp-dosing_mode_text_sensor:
|
||||
|
||||
``dosing_mode``
|
||||
-----------------------------
|
||||
|
||||
Indicates the dosing mode the pump is currently running as. Can be any of `Volume`, `Volume/Time`, `Constant Flow Rate`, `Continuous`, `None`.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
text_sensor:
|
||||
- platform: ezo_pmp
|
||||
dosing_mode:
|
||||
id: dosing_mode
|
||||
name: Dosing Mode
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||||
|
||||
.. _ezo_pmp-calibration_status_text_sensor:
|
||||
|
||||
``calibration_status``
|
||||
-----------------------------
|
||||
|
||||
Indicates calibration status of the pump. Can be any of `Fixed Volume`, `Volume/Time`, `Fixed Volume & Volume/Time` or `Uncalibrated`.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
text_sensor:
|
||||
- platform: ezo_pmp
|
||||
calibration_status:
|
||||
id: calibration_status
|
||||
name: Calibration Status
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas.
|
||||
- All other options from :ref:`Text Sensor <config-text_sensor>`.
|
||||
|
||||
Actions
|
||||
-----------------------------
|
||||
|
||||
.. _ezo_pmp-dose_continuously_action:
|
||||
|
||||
``ezo_pmp.dose_continuously`` Action
|
||||
------------------------------------
|
||||
|
||||
Use this action in an :ref:`automations <automation>` to have the peristaltic pump dose continuously
|
||||
at the :ref:`Maximum Flow Rate <ezo_pmp-max_flow_rate_sensor>`. The pump will automatically stop after 20 days
|
||||
of running in continuous mode.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.find:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
|
||||
.. _ezo_pmp-dose_volume_action:
|
||||
|
||||
``ezo_pmp.dose_volume`` Action
|
||||
------------------------------
|
||||
|
||||
Use this action in an :ref:`automations <automation>` to have the peristaltic pump dose an specific volume (in milliliters)
|
||||
at the :ref:`Maximum Flow Rate <ezo_pmp-max_flow_rate_sensor>`. If the volume is negative the pump will run backwards.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.dose_volume:
|
||||
id: ezo_pmp
|
||||
volume: 10
|
||||
|
||||
# Templated
|
||||
- ezo_pmp.dose_volume:
|
||||
id: ezo_pmp
|
||||
volume: !lambda |-
|
||||
return id(some_volume_sensor).state;
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
- **volume** (**Required**, float, :ref:`templatable <config-templatable>`): The volume to dose in milliliters. If negative, pump will run in reverse.
|
||||
|
||||
.. _ezo_pmp-dose_volume_over_time_action:
|
||||
|
||||
``ezo_pmp.dose_volume_over_time`` Action
|
||||
----------------------------------------
|
||||
|
||||
Use this action in an :ref:`automations <automation>` to have the peristaltic pump dose an specific `volume` (in milliliters)
|
||||
over the provided `duration` (in minutes). At the end of the time period the pump will have dosed the specified `volume`.
|
||||
If the volume is negative the pump will run backwards.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.dose_volume_over_time:
|
||||
id: ezo_pmp
|
||||
volume: 23.4
|
||||
duration: 2
|
||||
|
||||
# Templated
|
||||
- ezo_pmp.dose_volume_over_time:
|
||||
id: ezo_pmp
|
||||
volume: !lambda |-
|
||||
return id(some_volume_sensor).state;
|
||||
duration: !lambda |-
|
||||
return id(some_duration_sensor).state;
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
- **volume** (**Required**, float, :ref:`templatable <config-templatable>`): The volume to dose in milliliters. If negative, pump will run in reverse.
|
||||
- **duration** (**Required**, int, :ref:`templatable <config-templatable>`): The time (in minutes) the pump will take to dose the volume requested.
|
||||
|
||||
|
||||
.. _ezo_pmp-dose_with_constant_flow_rate_action:
|
||||
|
||||
``ezo_pmp.dose_with_constant_flow_rate`` Action
|
||||
-----------------------------------------------
|
||||
|
||||
Use this action in an :ref:`automations <automation>` to have the peristaltic pump dose an specific `volume` (in milliliters) every minute
|
||||
for the provided `duration` (in minutes). At the end of the time period the pump will have dosed the specified `volume` times the `duration`.
|
||||
If the volume is negative the pump will run backwards.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.dose_with_constant_flow_rate:
|
||||
id: ezo_pmp
|
||||
volume_per_minute: 10.2
|
||||
duration: 2
|
||||
|
||||
# Templated
|
||||
- ezo_pmp.dose_with_constant_flow_rate:
|
||||
id: ezo_pmp
|
||||
volume_per_minute: !lambda |-
|
||||
return id(some_volume_sensor).state;
|
||||
duration: !lambda |-
|
||||
return id(some_duration_sensor).state;
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
- **volume_per_minute** (**Required**, float, :ref:`templatable <config-templatable>`): The volume to dose in milliliters every minute. If negative, pump will run in reverse.
|
||||
- **duration** (**Required**, int, :ref:`templatable <config-templatable>`): The time (in minutes) the pump will dose the volume requested every minute.
|
||||
|
||||
.. _ezo_pmp-pause_dosing_action:
|
||||
|
||||
``ezo_pmp.pause_dosing`` Action
|
||||
-------------------------------
|
||||
|
||||
Use this action to pause a Dosing command that was previously issued. To determine if the dosing is paused or not, you can use the :ref:`Is Paused <ezo_pmp-is_paused_binary_sensor>` sensor.
|
||||
If the pump is currently paused, issuing this action again will unpause it.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.pause_dosing:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
.. _ezo_pmp-stop_dosing_action:
|
||||
|
||||
``ezo_pmp.stop_dosing`` Action
|
||||
------------------------------
|
||||
|
||||
Use this action to stop the current Dosing command.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.stop_dosing:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
.. _ezo_pmp-clear_total_volume_dosed_action:
|
||||
|
||||
``ezo_pmp.clear_total_volume_dosed`` Action
|
||||
-------------------------------------------
|
||||
|
||||
Clear the values of the :ref:`Current Volume Dosed <ezo_pmp-current_volume_dosed_sensor>`, :ref:`Total Volume Dosed <ezo_pmp-total_volume_dosed_sensor>`
|
||||
and :ref:`Absolute Total Volume Dosed <ezo_pmp-absolute_total_volume_dosed_sensor>` sensors.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.clear_total_volume_dosed:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
.. _ezo_pmp-set_calibration_volume_action:
|
||||
|
||||
``ezo_pmp.set_calibration_volume`` Action
|
||||
-----------------------------------------
|
||||
|
||||
Use this action to calibrate the peristaltic pump. The EZO-PMP needs two forms of calibration: absolute volume and volume over time. You can check
|
||||
the calibration status by using the :ref:`Calibration Status<ezo_pmp-calibration_status_text_sensor>` sensor. For the procedure on calibrating the pump
|
||||
check the datasheet.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.set_calibration_volume:
|
||||
id: ezo_pmp
|
||||
volume: 10.01
|
||||
|
||||
# Templated
|
||||
- ezo_pmp.set_calibration_volume:
|
||||
id: ezo_pmp
|
||||
volume: !lambda |-
|
||||
return id(some_volume_sensor).state;
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
- **volume** (**Required**, float, :ref:`templatable <config-templatable>`): The volume measured as part of the calibration process.
|
||||
|
||||
|
||||
.. _ezo_pmp-clear_calibration_action:
|
||||
|
||||
``ezo_pmp.clear_calibration`` Action
|
||||
------------------------------------
|
||||
|
||||
Clear the calibration values stored in the pump. You can check the calibration status by using the
|
||||
:ref:`Calibration Status<ezo_pmp-calibration_status_text_sensor>` sensor.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.clear_calibration:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
.. _ezo_pmp-find_action:
|
||||
|
||||
``ezo_pmp.find`` Action
|
||||
-----------------------
|
||||
|
||||
Use this action to make the LED on the Pump control board to blink for a minute. The pump will not respond to any other action while the LED is blinking.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.find:
|
||||
id: ezo_pmp
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
|
||||
.. _ezo_pmp-change_i2c_address_action:
|
||||
|
||||
``ezo_pmp.change_i2c_address`` Action
|
||||
-------------------------------------------
|
||||
|
||||
Changes the i2c address of the pump to the provided value. After the address is changed you must upload a new version of the ESPHome firmware with the updated I2C
|
||||
address for the pump to work.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
on_...:
|
||||
then:
|
||||
- ezo_pmp.change_i2c_address:
|
||||
id: ezo_pmp
|
||||
address: 100
|
||||
|
||||
Configuration options:
|
||||
|
||||
- **id** (**Required**, :ref:`config-id`): The ID of the pump.
|
||||
- **address** (**Required**, int, :ref:`templatable <config-templatable>`): The new I2C address for the pump.
|
||||
|
||||
.. _ezo-pmp-ha-config:
|
||||
|
||||
Home Assistant Configuration
|
||||
----------------------------
|
||||
|
||||
In order to provide control of the pump from the home assistant frontend it is important to expose the actions
|
||||
as components that have UI rendering. This could be done using templates in ESPHome. Here is an example using a
|
||||
`Template Button` and `Template Number` to dose a certain volume over time.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
i2c:
|
||||
|
||||
ezo_pmp:
|
||||
id: ezo_pmp
|
||||
|
||||
number:
|
||||
- platform: template
|
||||
id: volume
|
||||
name: "Volume"
|
||||
optimistic: true
|
||||
min_value: 0
|
||||
max_value: 100
|
||||
step: 0.01
|
||||
- platform: template
|
||||
id: duration
|
||||
name: "Duration"
|
||||
optimistic: true
|
||||
min_value: 0
|
||||
max_value: 100
|
||||
step: 1
|
||||
|
||||
button:
|
||||
- platform: template
|
||||
name: "Dose Over Time"
|
||||
on_press:
|
||||
- ezo_pmp.dose_volume_over_time:
|
||||
id: ezo_pump
|
||||
volume: !lambda |-
|
||||
return id(volume).state;
|
||||
duration: !lambda |-
|
||||
return id(duration).state;
|
||||
|
||||
.. _ezo_pmp-lambda_calls:
|
||||
|
||||
lambda calls
|
||||
------------
|
||||
|
||||
From :ref:`lambdas <config-lambda>`, you can also access the actions on the peristaltic pump to do some
|
||||
advanced stuff (see the full API Reference for more info). The name of the functions is the same as the name
|
||||
of the actions in YAML config.
|
||||
|
||||
See Also
|
||||
--------
|
||||
|
||||
- :apiref:`ezo_pmp/ezo_pmp.h`
|
||||
- :ghedit:`Edit`
|
BIN
components/images/ezo-pmp.jpg
Normal file
BIN
components/images/ezo-pmp.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 8.2 KiB |
BIN
images/ezo-pmp.jpg
Normal file
BIN
images/ezo-pmp.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 8.2 KiB |
Loading…
Reference in New Issue
Block a user