Holley DTZ541 Smart Meters
--------------------------
The Holley DTZ541 series of electricity meters have a faulty implementation of the SML protocol.
These meters send multiple conflicting values with the OBIS code ``1-0:1.8.0``, the code for the meter's energy reading.
Because the first value of every package is the correct value, in order to discard the erroneous values a throttle filter of 0.5s can be applied.
.. code-block:: yaml
sensor:
- platform: sml
name: "Total energy Consumption"
sml_id: mysml
obis_code: "1-0:1.8.0"
unit_of_measurement: kWh
accuracy_decimals: 5
device_class: energy
state_class: total_increasing
filters:
- throttle: 0.5s
- multiply: 0.0001
These meters can also measure the instantaneous power usage.
.. code-block:: yaml
sensor:
- platform: sml
name: "Instantaneous power"
sml_id: mysml
obis_code: "1-0:16.7.0"
unit_of_measurement: W
accuracy_decimals: 0
device_class: power
state_class: measurement