Documented Holley Meter SML hardware bug and workaround (#3099)
* Documented Holley Meter SML hardware bug and workaround * Documented Holley Meter SML hardware bug and workaround
This commit is contained in:
parent
c4fc718d48
commit
d029ac031e
|
@ -171,6 +171,41 @@ This results in problems when using the sensor in combination with the `Utility
|
|||
The state template provided above checks for the sensor's availability and keeps the
|
||||
current state in case of unavailability.
|
||||
|
||||
Holley DTZ541 Smart Meters
|
||||
--------------------------
|
||||
|
||||
The Holley DTZ541 series of electricity meters have a faulty implementation of the SML protocol.
|
||||
These meters send multiple conflicting values with the OBIS code ``1-0:1.8.0``, the code for the meter's energy reading.
|
||||
Because the first value of every package is the correct value, in order to discard the erroneous values a throttle filter of 0.5s can be applied.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: sml
|
||||
name: "Total energy Consumption"
|
||||
sml_id: mysml
|
||||
obis_code: "1-0:1.8.0"
|
||||
unit_of_measurement: kWh
|
||||
accuracy_decimals: 5
|
||||
device_class: energy
|
||||
state_class: total_increasing
|
||||
filters:
|
||||
- throttle: 0.5s
|
||||
- multiply: 0.0001
|
||||
|
||||
These meters can also measure the instantaneous power usage.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
sensor:
|
||||
- platform: sml
|
||||
name: "Instantaneous power"
|
||||
sml_id: mysml
|
||||
obis_code: "1-0:16.7.0"
|
||||
unit_of_measurement: W
|
||||
accuracy_decimals: 0
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
|
||||