components/sensors/pmsx003.rst: add config options for extra sensor data points (#1102)
Signed-off-by: John 'Warthog9' Hawley <warthog9@eaglescrag.net>
This commit is contained in:
parent
b8b7b9c1a8
commit
d22ba0b41c
@ -40,11 +40,29 @@ value:
|
|||||||
Configuration variables:
|
Configuration variables:
|
||||||
------------------------
|
------------------------
|
||||||
|
|
||||||
- **pm_1_0** (*Optional*): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter.
|
- **pm_1_0_std** (*Optional*): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter at standard particle
|
||||||
All options from :ref:`Sensor <config-sensor>`.
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
- **pm_2_5** (*Optional*): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter.
|
- **pm_2_5_std** (*Optional*): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter at standard particle
|
||||||
All options from :ref:`Sensor <config-sensor>`.
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
- **pm_10_0** (*Optional*): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter.
|
- **pm_10_0_std** (*Optional*): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter at standard particle
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_1_0** (*Optional*): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter under atmospheric environment
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_2_5** (*Optional*): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter under atmospheric environment
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_10_0** (*Optional*): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter under atmospheric environment
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_0_3um** (*Optional*): Use the number of particles with diameter beyond 0.3um in 0.1L of air
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_0_5um** (*Optional*): Use the number of particles with diameter beyond 0.5um in 0.1L of air
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_1_0um** (*Optional*): Use the number of particles with diameter beyond 1.0um in 0.1L of air
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_2_5um** (*Optional*): Use the number of particles with diameter beyond 2.5um in 0.1L of air
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_5_0um** (*Optional*): Use the number of particles with diameter beyond 5.0um in 0.1L of air
|
||||||
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|
- **pm_10_0um** (*Optional*): Use the number of particles with diameter beyond 10.0um in 0.1L of air
|
||||||
All options from :ref:`Sensor <config-sensor>`.
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
- **temperature** (*Optional*): Use the temperature value in °C for the ``PMS5003T`` and ``PMS5003ST``.
|
- **temperature** (*Optional*): Use the temperature value in °C for the ``PMS5003T`` and ``PMS5003ST``.
|
||||||
All options from :ref:`Sensor <config-sensor>`.
|
All options from :ref:`Sensor <config-sensor>`.
|
||||||
|