add possibility to provide different conversion times for Bus Voltage… (#3661)
Co-authored-by: Kevin Hübner <k.huebner@ceyoniq.com>
This commit is contained in:
parent
c02f4106d8
commit
d47883aa54
@ -27,6 +27,9 @@ The :ref:`I²C Bus <i2c>` is required to be set up in your configuration for thi
|
|||||||
address: 0x40
|
address: 0x40
|
||||||
shunt_resistance: 0.1 ohm
|
shunt_resistance: 0.1 ohm
|
||||||
max_current: 3.2A
|
max_current: 3.2A
|
||||||
|
# adc time used for both, Bus Voltage and Shunt Voltage
|
||||||
|
adc_time: 140us
|
||||||
|
adc_averaging: 128
|
||||||
update_interval: 60s
|
update_interval: 60s
|
||||||
current:
|
current:
|
||||||
name: "INA226 Current"
|
name: "INA226 Current"
|
||||||
@ -37,6 +40,17 @@ The :ref:`I²C Bus <i2c>` is required to be set up in your configuration for thi
|
|||||||
shunt_voltage:
|
shunt_voltage:
|
||||||
name: "INA226 Shunt Voltage"
|
name: "INA226 Shunt Voltage"
|
||||||
|
|
||||||
|
.. code-block:: yaml
|
||||||
|
|
||||||
|
# Example configuration entry
|
||||||
|
sensor:
|
||||||
|
- platform: ina226
|
||||||
|
address: 0x40
|
||||||
|
adc_time:
|
||||||
|
voltage: 140us
|
||||||
|
current: 332us
|
||||||
|
|
||||||
|
|
||||||
Configuration variables:
|
Configuration variables:
|
||||||
------------------------
|
------------------------
|
||||||
|
|
||||||
@ -45,9 +59,12 @@ Configuration variables:
|
|||||||
Defaults to ``0.1 ohm``.
|
Defaults to ``0.1 ohm``.
|
||||||
- **max_current** (*Optional*, float): The maximum current you are expecting. ESPHome will use this to
|
- **max_current** (*Optional*, float): The maximum current you are expecting. ESPHome will use this to
|
||||||
configure the sensor optimally. Defaults to ``3.2A``.
|
configure the sensor optimally. Defaults to ``3.2A``.
|
||||||
- **adc_time** (*Optional*, :ref:`config-time`): The time in microseconds to perform a single ADC conversion.
|
- **adc_time** (*Optional*, :ref:`config-time` or both of the following nested options): The time in microseconds to perform a single ADC conversion.
|
||||||
Defaults to ``1100us``. Valid values are ``140us``, ``204us``, ``332us``, ``588us``, ``1100us``, ``2116us``,
|
Defaults to ``1100us``. Valid values are ``140us``, ``204us``, ``332us``, ``588us``, ``1100us``, ``2116us``,
|
||||||
``4156us``, ``8244us``.
|
``4156us``, ``8244us``.
|
||||||
|
|
||||||
|
- **voltage** (**Required**, :ref:`config-time`) ADC conversion time for Bus Voltage
|
||||||
|
- **current** (**Required**, :ref:`config-time`) ADC conversion time for Shunt Voltage (Current measurement)
|
||||||
- **adc_averaging** (*Optional*, integer): Selects ADC sample averaging count. Defaults to ``4``. Valid values are
|
- **adc_averaging** (*Optional*, integer): Selects ADC sample averaging count. Defaults to ``4``. Valid values are
|
||||||
``1``, ``4``, ``16``, ``64``, ``128``, ``256``, ``512``, ``1024``.
|
``1``, ``4``, ``16``, ``64``, ``128``, ``256``, ``512``, ``1024``.
|
||||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
||||||
|