Merge branch 'current' into beta

This commit is contained in:
Jesse Hills 2022-11-10 11:08:13 +13:00
commit da4402105e
No known key found for this signature in database
GPG Key ID: BEAAE804EFD8E83A
8 changed files with 153 additions and 17 deletions

View File

@ -238,6 +238,19 @@ Connect RX from BMS to TX in ESP board and TX from BMS to RX in ESP board
:width: 100.0% :width: 100.0%
Uart Pinout. Uart Pinout.
**3.3v Warning:** some BMS 3.3v cant source large currents and may not work to properly power the ESP. If you are having WIFI connection issues or similar, try a different power source. There is 12-15v available on the Daly connector which via a proper step-down converter can properly power the ESP.
On the ESP32 (untested on ESP8266) if you are having missing data (such as Temperature 1/2), it may be due to UART buffer size.
Add the following to your configuration to increase the buffer from the default 256 to 512.
.. code-block::
uart:
...
rx_buffer_size: 512
See Also See Also
-------- --------

View File

@ -129,6 +129,43 @@ trying to match.
This value is the raw count of pulses, and not the value you see after the filters This value is the raw count of pulses, and not the value you see after the filters
are applied. are applied.
Wiring
------
If you want to count pulses from a simple reed switch, the simplest way is to make
use of the internal pull-up/pull-down resistors.
You can wire the switch between a GPIO pin and GND; in this case set the pin to input, pullup and inverted:
.. code-block:: yaml
# Reed switch between GPIO and GND
sensor:
- platform: pulse_counter
pin:
number: 12
inverted: true
mode:
input: true
pullup: true
name: "Pulse Counter"
If you wire it between a GPIO pin and +3.3V, set the pin to input, pulldown:
.. code-block:: yaml
# Reed switch between GPIO and +3.3V
sensor:
- platform: pulse_counter
pin:
number: 12
mode:
input: true
pulldown: true
name: "Pulse Counter"
The safest way is to use GPIO + GND, as this avoids the possibility of short
circuiting the wire by mistake.
See Also See Also
-------- --------

View File

@ -4,7 +4,7 @@ Eastron SDM Energy Monitor
.. seo:: .. seo::
:description: Instructions for setting up SDM power monitors. :description: Instructions for setting up SDM power monitors.
:image: sdm220m.jpg :image: sdm220m.jpg
:keywords: SDM220M, SDM220, SDM630 :keywords: SDM230M, SDM220, SDM630, SDM120M, SDM72
The ``sdm_meter`` sensor platform allows you to use Eastron SDM modbus energy monitors The ``sdm_meter`` sensor platform allows you to use Eastron SDM modbus energy monitors
(`website <http://www.eastrongroup.com/product_detail.php?id=170&menu1=&menu2=>`__) (`website <http://www.eastrongroup.com/product_detail.php?id=170&menu1=&menu2=>`__)
@ -14,12 +14,13 @@ with ESPHome.
:align: center :align: center
:width: 50.0% :width: 50.0%
SDM220M Energy Monitor. SDM230M Energy Monitor.
The communication with this integration is done over a :ref:`UART bus <uart>` using the :ref:`Modbus protocol <modbus>` The communication with this integration is done over a :ref:`UART bus <uart>` using the :ref:`Modbus protocol <modbus>`
over RS485 wiring. You will need an RS485 to UART converter for communication. over RS485 wiring. You will need an RS485 to UART converter for communication.
You must therefore have a ``uart:`` entry in your configuration with both the TX and RX pins set You must therefore have a ``uart:`` entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600. to some pins on your board and the baud rate set to 9600bps.
! For the SDM230M, SDM120M Energy Monitor the default factory baud rate is 2400bps. You either need to change the code to 2400bps for these models or change the settings on your Energy Meter For more information search for your model: (`eastron's website <https://www.eastroneurope.com/products/category/din-rail-mounted-metering>`__).
.. code-block:: yaml .. code-block:: yaml
@ -27,38 +28,38 @@ to some pins on your board and the baud rate set to 9600.
uart: uart:
rx_pin: D1 rx_pin: D1
tx_pin: D2 tx_pin: D2
baud_rate: 9600 baud_rate: 9600 #if your energy meter is SDM230M or SDM120M than change the baud_rate: 2400
stop_bits: 1 stop_bits: 1
sensor: sensor:
- platform: sdm_meter - platform: sdm_meter
phase_a: phase_a:
current: current:
name: "SDM220M Current" name: "SDM230M Current"
voltage: voltage:
name: "SDM220M Voltage" name: "SDM230M Voltage"
active_power: active_power:
name: "SDM220M Power" name: "SDM230M Power"
power_factor: power_factor:
name: "SDM220M Power Factor" name: "SDM230M Power Factor"
apparent_power: apparent_power:
name: "SDM220M Apparent Power" name: "SDM230M Apparent Power"
reactive_power: reactive_power:
name: "SDM220M Reactive Power" name: "SDM230M Reactive Power"
phase_angle: phase_angle:
name: "SDM220M Phase Angle" name: "SDM230M Phase Angle"
frequency: frequency:
name: "SDM220M Frequency" name: "SDM230M Frequency"
total_power: total_power:
name: "SDM220M Total Power" name: "SDM230M Total Power"
import_active_energy: import_active_energy:
name: "SDM220M Import Active Energy" name: "SDM230M Import Active Energy"
export_active_energy: export_active_energy:
name: "SDM220M Export Active Energy" name: "SDM230M Export Active Energy"
import_reactive_energy: import_reactive_energy:
name: "SDM220M Import Reactive Energy" name: "SDM230M Import Reactive Energy"
export_reactive_energy: export_reactive_energy:
name: "SDM220M Export Reactive Energy" name: "SDM230M Export Reactive Energy"
update_interval: 60s update_interval: 60s
@ -113,3 +114,4 @@ See Also
- :ref:`sensor-filters` - :ref:`sensor-filters`
- :apiref:`sdm220m/sdm220m.h` - :apiref:`sdm220m/sdm220m.h`
- :ghedit:`Edit` - :ghedit:`Edit`

View File

@ -0,0 +1,80 @@
Geiger counter RadiationD v1.1 (CAJOE)
======================================
.. seo::
:description: Instructions for setting up RadiationD v1.1(CAJOE) sensor in ESPHome and calculate the current radation level.
:image: radiationD-v1-1-cajoe_small.jpg
:keywords: Radiation Geiger counter
With the help of :doc:`/components/sensor/pulse_counter` and the RadiationD v1.1(CAJOE) you can make your own Geiger counter, which will give you
a more or less precise messurement of the current radation level. But it should be good enough to warn you about critical events.
Assambly:
---------
.. figure:: images/radiationD-v1-1-cajoe_small.jpg
:align: center
:width: 100.0%
The first step is to connect the sensor.
You just need to connect the +5V, the ground and a GPIO pin to the ESP.
In my case I used the pin 34 for the signal. (The print on the PCB is wrong VIN is the signal.)
This setup should give you the pulse of each messurement or count. For more information check the Video of `Andreas Spiess <https://www.youtube.com/watch?v=K28Az3-gV7E>`__.
Housing:
*********
I just 3D printed an small housing the avoid touching the high voltage Geiger Mueller tube.
`Counter Tube Case <https://www.thingiverse.com/thing:5425224>`__
(The tube should not be in direct sunlight. So maybe you will need another case.)
Configuartion:
---------------
The block :doc:`/components/sensor/pulse_counter` will count the radation events per minute.
With the found specs of the tube you will be able to calculate the radiation in μSv/h.
It's just the counts per minute (CPM) times the factor of your Geiger Mueller tube you're using. It should be the J305ß, which comes with the PCB.
(To make sure - check your printing on the tube)
μSv/h = (CPM - Tube noise) * Factor
According to the video of `Andreas Spiess <https://www.youtube.com/watch?v=K28Az3-gV7E>`__ the tube should have about 12 CPM as background noise.
.. note::
The current version of the pack comes with the J305ß Geiger tube which detectes Beta and Gamma radiation. Specifications:
Manufacturer: North Optic Radiation Detection: β, γ Length: 111mm Diameter: 11mm Recommended Voltage: 350V Plateau Voltage: 360-440V
Sensitivy γ (60Co): 65cps/(μR/s)
Sensitivy γ (equivalent Sievert): 108cpm / (μSv/h)
Max cpm: 30000
cps/mR/h: 18
cpm/m/h: 1080
cpm/μSv/h: 123.147092360319
Factor: 0.00812037037037
`Source: opengeiger.de/LibeliumDoku.pdf <http://www.opengeiger.de/LibeliumDoku.pdf>`__.
.. code-block:: yaml
sensor:
- platform: pulse_counter
pin: 34
name: "Radiation"
unit_of_measurement: 'μSv/h'
count_mode:
rising_edge: DISABLE
falling_edge: INCREMENT
filters:
- offset: -12.0 # J305ß Geiger Mueller tube background noise 0.2 pulses / sec x 60 sec = 12 CPM (Counts per Minute)
- multiply: 0.00812037037037 # Factor: 0.00812037037037
See Also
--------
- :doc:`/components/sensor/pulse_counter`
- :ghedit:`Edit`

Binary file not shown.

After

Width:  |  Height:  |  Size: 12 KiB

View File

@ -49,6 +49,9 @@ And in YAML:
- lambda: |- - lambda: |-
auto my_custom = new MyCustomComponent(); auto my_custom = new MyCustomComponent();
return {my_custom}; return {my_custom};
components:
- id: my_custom_id
Configuration variables: Configuration variables:

Binary file not shown.

After

Width:  |  Height:  |  Size: 12 KiB

View File

@ -746,6 +746,7 @@ Cookbook
EPEVER Tracer, cookbook/tracer-an, tracer-an.jpg EPEVER Tracer, cookbook/tracer-an, tracer-an.jpg
Ilonda Wifi Smart Fish Feeder, cookbook/ilonda-wifi-smart-fish-feeder, ilonda-wifi-smart-fish-feeder-cookbook.jpg Ilonda Wifi Smart Fish Feeder, cookbook/ilonda-wifi-smart-fish-feeder, ilonda-wifi-smart-fish-feeder-cookbook.jpg
AirGradient DIY Air Quality Sensor, cookbook/air_gradient_diy_air_quality_sensor, air_gradient_diy_air_quality_sensor.jpg AirGradient DIY Air Quality Sensor, cookbook/air_gradient_diy_air_quality_sensor, air_gradient_diy_air_quality_sensor.jpg
Geiger Counter, cookbook/geiger-counter, radiationD-v1-1-cajoe_small.jpg
Do you have other awesome automations or cool setups? Please feel free to add them to the Do you have other awesome automations or cool setups? Please feel free to add them to the
documentation for others to copy. See :doc:`Contributing </guides/contributing>`. documentation for others to copy. See :doc:`Contributing </guides/contributing>`.