diff --git a/components/climate/climate_ir.rst b/components/climate/climate_ir.rst index e2f0bbacd..6f67f8f9c 100644 --- a/components/climate/climate_ir.rst +++ b/components/climate/climate_ir.rst @@ -114,9 +114,18 @@ This platform utilises the library's generic one-size-fits-all API, which might Additional configuration must be specified for this platform: -- **protocol** (**Required**, string): Choose one of Arduino-HeatpumpIR's supported protcols: ``aux``, ``ballu``, ``carrier_mca``, ``carrier_nqv``, ``daikin_arc417``, ``daikin_arc480``, ``daikin``, ``electroluxyal``, ``fuego``, ``fujitsu_awyz``, ``gree``, ``greeya``, ``greeyac``, ``greeyan``, ``greeyt``, ``hisense_aud``, ``hitachi``, ``hyundai``, ``ivt``, ``midea``, ``mitsubishi_fa``, ``mitsubishi_fd``, ``mitsubishi_fe``, ``mitsubishi_heavy_fdtc``, ``mitsubishi_heavy_zj``, ``mitsubishi_heavy_zm``, ``mitsubishi_heavy_zmp``, ``mitsubishi_heavy_kj``, ``mitsubishi_msc``, ``mitsubishi_msy``, ``mitsubishi_sez``, ``panasonic_ckp``, ``panasonic_dke``, ``panasonic_jke``, ``panasonic_lke``, ``panasonic_nke``, ``samsung_aqv``, ``samsung_fjm``, ``sharp``, ``toshiba_daiseikai``, ``toshiba``, ``zhlt01`` -- **horizontal_default** (**Required**, string): What to default to when the AC unit's horizontal direction is *not* set to swing. Options are: ``left``, ``mleft``, ``middle``, ``mright``, ``right``, ``auto`` -- **vertical_default** (**Required**, string): What to default to when the AC unit's vertical direction is *not* set to swing. Options are: ``down``, ``mdown``, ``middle``, ``mup``, ``up``, ``auto`` +- **protocol** (**Required**, string): Choose one of Arduino-HeatpumpIR's supported protcols: + ``aux``, ``ballu``, ``carrier_mca``, ``carrier_nqv``, ``carrier_qlima_1``, ``carrier_qlima_1``, ``daikin``, ``daikin_arc417``, + ``daikin_arc480``, ``electroluxyal``, ``fuego``, ``fujitsu_awyz``, ``gree``, ``greeyaa``, ``greeyac``, ``greeyan``, ``greeyap``, + ``greeyt``, ``hisense_aud``, ``hitachi``, ``hyundai``, ``ivt``, ``midea``, ``mitsubishi_fa``, ``mitsubishi_fd``, + ``mitsubishi_fe``, ``mitsubishi_heavy_fdtc``, ``mitsubishi_heavy_zj``, ``mitsubishi_heavy_zm``, ``mitsubishi_heavy_zmp``, + ``mitsubishi_kj``, ``mitsubishi_msc``, ``mitsubishi_msy``, ``mitsubishi_sez``, ``nibe``, ``panasonic_ckp``, ``panasonic_dke``, + ``panasonic_jke``, ``panasonic_lke``, ``panasonic_nke``, ``samsung_aqv``, ``samsung_aqv12msan``, + ``samsung_fjm``, ``sharp``, ``toshiba``, ``toshiba_daiseikai``, ``zhjg01``, ``zhlt01``. + + +- **horizontal_default** (**Required**, string): What to default to when the AC unit's horizontal direction is *not* set to swing. Options are: ``left``, ``mleft``, ``middle``, ``mright``, ``right``, ``auto``. +- **vertical_default** (**Required**, string): What to default to when the AC unit's vertical direction is *not* set to swing. Options are: ``down``, ``mdown``, ``middle``, ``mup``, ``up``, ``auto``. - **max_temperature** (**Required**, float): The maximum temperature that the AC unit supports being set to. - **min_temperature** (**Required**, float): The minimum temperature that the AC unit supports being set to. - **sensor** (*Optional*, :ref:`config-id`): The sensor that is used to measure the ambient temperature.