@ -13,8 +13,8 @@ The ``bme680_bsec`` sensor platform allows you to use your BME680
|
||||
(`datasheet <https://cdn-shop.adafruit.com/product-files/3660/BME680.pdf>`__,
|
||||
`Adafruit`_) temperature, pressure and humidity and gas sensors with ESPHome via the Bosch Sensortec Environmental Cluster (BSEC)
|
||||
software library. The use of Bosch's proprietary algorithms provide an Index for Air Quality (IAQ) measurement derived from the
|
||||
gas resistance sensor's response to specific Volatile Organic Compounds (VOC). The BSEC software also provides estimated values
|
||||
for CO₂ and Breath Volatile Organic Compounds (b-VOC) using a correlation between VOC and CO₂ in a human's exhaled breath.
|
||||
gas resistance sensor's response to specific Volatile Organic Compounds (VOC). The BSEC software also provides estimated values
|
||||
for CO₂ and Breath Volatile Organic Compounds (b-VOC) using a correlation between VOC and CO₂ in a human's exhaled breath.
|
||||
|
||||
.. note::
|
||||
|
||||
@ -61,7 +61,7 @@ The :ref:`I²C <i2c>` is required to be set up in your configuration for this se
|
||||
- platform: bme680_bsec
|
||||
iaq_accuracy:
|
||||
name: "BME680 IAQ Accuracy"
|
||||
|
||||
|
||||
- platform: template
|
||||
name: "BME680 IAQ Classification"
|
||||
icon: "mdi:checkbox-marked-circle-outline"
|
||||
@ -299,7 +299,6 @@ For each sensor, all other options from :ref:`Sensor <config-sensor>` and :ref:`
|
||||
name: "BME680 IAQ Accuracy"
|
||||
|
||||
|
||||
<<<<<<< HEAD
|
||||
Multiple sensors
|
||||
----------------------
|
||||
|
||||
@ -370,15 +369,11 @@ The following configuration shows how to set up multiple BME680 devices. They ca
|
||||
iaq_accuracy:
|
||||
name: "OUT_IAQaccuracy"
|
||||
|
||||
|
||||
Indoor Air Quality (IAQ) Measurement
|
||||
------------------------------------
|
||||
=======
|
||||
Index for Air Quality (IAQ) Measurement
|
||||
---------------------------------------
|
||||
|
||||
The measurements are expressed with an index scale ranging from 0 to 500. The index itself is deduced
|
||||
from tests using ethanol gas, as well as important VOC in the exhaled breath of healthy humans.
|
||||
The measurements are expressed with an index scale ranging from 0 to 500. The index itself is deduced
|
||||
from tests using ethanol gas, as well as important VOC in the exhaled breath of healthy humans.
|
||||
The VOC values themselves are derived from several publications on breath analysis studies. The BSEC
|
||||
software library defines the levels as follows:
|
||||
|
||||
@ -399,7 +394,7 @@ software library defines the levels as follows:
|
||||
+-----------+---------------------+
|
||||
| > 351 | Extremely polluted |
|
||||
+-----------+---------------------+
|
||||
|
||||
|
||||
The selected b-VOC gasses are as follows:
|
||||
|
||||
+--------------------+----------------+
|
||||
@ -421,7 +416,6 @@ The selected b-VOC gasses are as follows:
|
||||
.. _Ethanol: https://en.wikipedia.org/wiki/Ethanol
|
||||
.. _Acetone: https://en.wikipedia.org/wiki/Acetone
|
||||
.. _Carbon Monoxide: https://en.wikipedia.org/wiki/Carbon_monoxide
|
||||
>>>>>>> current
|
||||
|
||||
|
||||
.. _bsec-calibration:
|
||||
@ -429,8 +423,8 @@ The selected b-VOC gasses are as follows:
|
||||
IAQ Accuracy and Calibration
|
||||
----------------------------
|
||||
|
||||
The BSEC software automatically calibrates automatically in the background to provide consistent IAQ performance. The
|
||||
calibration process considers the recent measurement history so that a value of 50 corresponds to a “typical good”
|
||||
The BSEC software automatically calibrates automatically in the background to provide consistent IAQ performance. The
|
||||
calibration process considers the recent measurement history so that a value of 50 corresponds to a “typical good”
|
||||
level and a value of 200 to a “typical polluted” level. The IAQ Accuracy sensor will give one of the following values:
|
||||
|
||||
- ``Stabilizing``: The device has just started, and the sensor is stabilizing (this typically lasts 5 minutes)
|
||||
|