Mitsubishi update (#2353)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com> Co-authored-by: RubyBailey <ruby_bailey11@hotmail.com>
This commit is contained in:
parent
031ea607a8
commit
df6b8af452
|
@ -42,7 +42,7 @@ submit a feature request (see FAQ).
|
|||
+---------------------------------------+---------------------+----------------------+
|
||||
| Midea | ``midea_ir`` | yes |
|
||||
+---------------------------------------+---------------------+----------------------+
|
||||
| Mitsubishi | ``mitsubishi`` | |
|
||||
| :ref:`Mitsubishi<mitsubishi>` | ``mitsubishi`` | yes |
|
||||
+---------------------------------------+---------------------+----------------------+
|
||||
| Noblex | ``noblex`` | yes |
|
||||
+---------------------------------------+---------------------+----------------------+
|
||||
|
@ -253,6 +253,48 @@ Known working with:
|
|||
|
||||
- Delonghi PAC WE 120HP
|
||||
|
||||
.. _mitsubishi:
|
||||
|
||||
``mitsubishi`` Climate
|
||||
------------------------
|
||||
|
||||
Additonal configurations available for this platform.
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **set_fan_mode** (*Optional*, string): Select the fan modes desired or that are supported on your remote. Defaults to ``3levels``
|
||||
|
||||
- Options are: ``3levels`` , ``4levels``, ``quiet_4levels``.
|
||||
|
||||
- ``3levels``; Low [fan speed 1], Medium [2], High [3]
|
||||
- ``4levels``; Low [1], Middle [2], Medium [3], High [4]
|
||||
- ``quiet_4levels``; Low [1], Middle [2], Medium [3], High [4], Quiet [5]
|
||||
|
||||
- **supports_dry** (*Optional*, boolean): Enables setting dry mode for this unit. Defaults to ``false``.
|
||||
- **supports_fan_only** (*Optional*, boolean): Enables setting fan only mode for this unit. Confirm that mode is supported on your remote. Defaults to ``false``.
|
||||
|
||||
- **horizontal_default** (*Optional*, string): What to default to when the AC unit's horizontal direction is *not* set to swing. Defaults to ``middle``.
|
||||
|
||||
- Options are: ``left``, ``middle-left``, ``middle``, ``middle-right``, ``right``, ``auto``
|
||||
- **vertical_default** (*Optional*, string): What to default to when the AC unit's vertical direction is *not* set to swing. Defaults to ``middle``.
|
||||
|
||||
- Options are: ``down``, ``middle-down``, ``middle``, ``middle-up``, ``up``, ``auto``
|
||||
|
||||
.. note::
|
||||
|
||||
- This climate IR component is also known to work with some Stiebel Eltron Units. It has been tested with Stiebel Eltron IR-Remote ``KM07F`` and unit ``ACW 25 i``
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
# Example configuration entry
|
||||
climate:
|
||||
- platform: mitsubishi
|
||||
name: "Heatpump"
|
||||
set_fan_mode: "quiet_4levels"
|
||||
supports_dry: "true"
|
||||
supports_fan_only: "true"
|
||||
horizontal_default: "left"
|
||||
vertical_default: "down"
|
||||
|
||||
.. _toshiba:
|
||||
|
||||
|
@ -284,7 +326,7 @@ Configuration variables:
|
|||
``update_interval`` must be less than seven minutes or the ``RAC-PT1411HWRU`` will revert to using its own
|
||||
internal temperature sensor; a value of 30 seconds seems to work well. See :doc:`/components/sensor/index`
|
||||
for more information.
|
||||
|
||||
|
||||
- This climate IR component is also known to work with Midea model MAP14HS1TBL and may work with other similar
|
||||
models, as well. (Midea acquired Toshiba's product line and re-branded it.)
|
||||
|
||||
|
|