ADE7953: Add the ability to use accumulating energy registers, more precise power reporting (#3656)
This commit is contained in:
parent
707614f1cf
commit
e31870f247
|
@ -122,6 +122,7 @@ Configuration variables:
|
|||
- **active_power_gain_a** (*Optional*, int): Set the active power amplification of the A channel. Defaults to ``0x400000``.
|
||||
- **active_power_gain_b** (*Optional*, int): Set the active power amplification of the B channel. Defaults to ``0x400000``.
|
||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
||||
- **use_accumulated_energy_registers** (*Optional*, boolean): Use ADE7935 accumulated energy registers instead of instant power registers. These registers store the accumulated energy since the last read and should provide better accuracy for power calculation. Defaults to ``false``.
|
||||
|
||||
Over SPI
|
||||
--------
|
||||
|
@ -253,6 +254,7 @@ Configuration variables:
|
|||
- **active_power_gain_a** (*Optional*, int): Set the active power amplification of the A channel. Defaults to ``0x400000``.
|
||||
- **active_power_gain_b** (*Optional*, int): Set the active power amplification of the B channel. Defaults to ``0x400000``.
|
||||
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``.
|
||||
- **use_accumulated_energy_registers** (*Optional*, boolean): Use ADE7935 accumulated energy registers instead of instant power registers. These registers store the accumulated energy since the last read and should provide better accuracy for power calculation. Defaults to ``false``.
|
||||
|
||||
Use with Shelly 2.5
|
||||
-------------------
|
||||
|
|