PCF8563 Time Source ==================== You first need to set up the :doc:`I2C ` component. .. code-block:: yaml # Example configuration entry time: - platform: pcf8563 id: pcf8563_time Configuration variables ----------------------- - **address** (*Optional*, int): Manually specify the I²C address of the RTC. Defaults to ``0xA3``. - All other options from :ref:`base_time_config`. .. _pcf8563-write_time_action: ``pcf8563.write_time`` Action ------------------------------ This :ref:`Action ` triggers a synchronization of the current system time to the RTC hardware. .. note:: PCFe pcf8563 component will *not* write the RTC clock if not triggered *explicitly* by this action. .. code-block:: yaml on_...: - pcf8563.write_time # in case you need to specify the DS1307 id - pcf8563.write_time: id: pcf8563_time .. _pcf8563-read_time_action: ``pcf8563.read_time`` Action ----------------------------- This :ref:`Action ` triggers a synchronization of the current system time from the RTC hardware. .. note:: The PCF8563 component will automatically read the RTC clock every 15 minutes by default and synchronize the system clock when a valid timestamp was read from the RTC. (The ``update_interval`` can be changed.) This action can be used to trigger *additional* synchronizations. .. code-block:: yaml on_...: - pcf8563.read_time # in case you need to specify the PCF8563 id - pcf8563.read_time: id: pcf8563_time .. _pcf8563-config_example: Full Configuration Example -------------------------- In a typical setup, you will have at least one additional time source to synchronize the RTC with. Such an external time source might not always be available e.g. due to a limited network connection. In order to have a valid, reliable system time, the system should read the RTC once at start and then try to synchronize with an external reliable time source. When a synchronization to another time source was successful, the RTC can be resynchronized. .. code-block:: yaml esphome: on_boot: then: # read the RTC time once when the system boots pcf8563.read_time: time: - platform: pcf8563 # repeated synchronization is not necessary unless the external RTC # is much more accurate than the internal clock update_interval: never - platform: homeassistant # instead try to synchronize via network repeatedly ... on_time_sync: then: # ... and update the RTC when the synchronization was successful pcf8563.write_time: See Also -------- - :ghedit:`Edit`