Peacefair PZEM-004T V3 Energy Monitor
=====================================
.. seo::
:description: Instructions for setting up PZEM-004T power monitors.
:image: pzem-ac.png
:keywords: PZEM-004T V3
.. note::
This page is incomplete and could use some work. If you want to contribute, please read the
:doc:`contributing guide `. This page is missing:
- Images/screenshots/example configs of this device being used in action.
The ``pzemac`` sensor platform allows you to use PZEM-004T V3 energy monitors
(`website `__,
`datasheet `__)
with ESPHome.
The sensor can be connected in various configurations - please see the `manufacturer's website `__
for more information.
.. figure:: images/pzem-ac.png
:align: center
:width: 80.0%
PZEM-004T Version 3.
.. warning::
This page refers to version V3 of the PZEM004T.
For using the older V1 variant of this sensor please see :doc:`pzem004t `.
The communication with this integration is done over a :ref:`UART bus ` using :ref:`Modbus `.
You must therefore have a ``uart:`` entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 9600.
.. code-block:: yaml
# Example configuration entry
uart:
rx_pin: D1
tx_pin: D2
baud_rate: 9600
modbus:
sensor:
- platform: pzemac
current:
name: "PZEM-004T V3 Current"
voltage:
name: "PZEM-004T V3 Voltage"
energy:
name: "PZEM-004T V3 Energy"
power:
name: "PZEM-004T V3 Power"
frequency:
name: "PZEM-004T V3 Frequency"
power_factor:
name: "PZEM-004T V3 Power Factor"
update_interval: 60s
Configuration variables:
------------------------
- **current** (*Optional*): Use the current value of the sensor in amperes. All options from
:ref:`Sensor `.
- **energy** (*Optional*): Use the (active) energy value of the sensor in watt*hours. All options from
:ref:`Sensor `.
- **power** (*Optional*): Use the (active) power value of the sensor in watts. All options from
:ref:`Sensor `.
- **voltage** (*Optional*): Use the voltage value of the sensor in volts.
All options from :ref:`Sensor `.
- **frequency** (*Optional*): Use the frequency value of the sensor in hertz.
All options from :ref:`Sensor `.
- **power_factor** (*Optional*): Use the power factor value of the sensor.
All options from :ref:`Sensor `.
- **update_interval** (*Optional*, :ref:`config-time`): The interval to check the
sensor. Defaults to ``60s``.
- **address** (*Optional*, int): The address of the sensor if multiple sensors are attached to
the same UART bus. You will need to set the address of each device manually. Defaults to ``1``.
- **modbus_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the Modbus hub.
.. _pzemac-reset_energy_action:
``pzemac.reset_energy`` Action
******************************
This action resets the total energy value of the pzemac device with the given ID when executed.
.. code-block:: yaml
on_...:
then:
- pzemac.reset_energy: pzemac_1
Changing the address of a PZEM-004T:
------------------------------------
You can use the following configuration to change the address of a sensor.
You must set the ``address`` of the ``modbus_controller`` to the current address, and ``new_address`` of the ``on_boot`` lambda to the new one.
.. warning::
This should be used only once! After changing the address, this code should be removed from the ESP before using the actual sensor code.
.. code-block:: yaml
esphome:
...
on_boot:
## configure controller settings at setup
## make sure priority is lower than setup_priority of modbus_controller
priority: -100
then:
- lambda: |-
auto new_address = 0x03;
if(new_address < 0x01 || new_address > 0xF7) // sanity check
{
ESP_LOGE("ModbusLambda", "Address needs to be between 0x01 and 0xF7");
return;
}
esphome::modbus_controller::ModbusController *controller = id(pzem);
auto set_addr_cmd = esphome::modbus_controller::ModbusCommandItem::create_write_single_command(
controller, 0x0002, new_address);
delay(200) ;
controller->queue_command(set_addr_cmd);
ESP_LOGI("ModbusLambda", "PZEM Addr set");
modbus:
send_wait_time: 200ms
id: mod_bus_pzem
modbus_controller:
- id: pzem
## the current device addr
address: 0x1
modbus_id: mod_bus_pzem
command_throttle: 0ms
setup_priority: -10
update_interval: 30s
See Also
--------
- :ref:`sensor-filters`
- :doc:`pzem004t`
- :doc:`pzemdc`
- :apiref:`pzemac/pzemac.h`
- :ghedit:`Edit`