EE895 CO₂, Temperature and Pressure Sensor =================================================== .. seo:: :description: Instructions for setting up EE895 CO₂ Temperature and Pressure :image: EE895.png The ``ee895`` sensor platform allows you to use your EE895 CO₂ (`datasheet `__, `E+E EE895 `__) sensor with ESPHome. The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. We recommend the use of pull up resistors. .. figure:: images/EE895.png :align: center :width: 80.0% .. code-block:: yaml # Example configuration entry sensor: - platform: ee895 co2: name: "Office CO2" accuracy_decimals: 0 temperature: name: "Office Temperature" accuracy_decimals: 2 pressure: name: "Office Pressure" accuracy_decimals: 1 address: 0x5F update_interval: 15s Configuration variables: ------------------------ - **temperature** (**Required**): The information for the Temperature sensor. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **co2** (**Required**): The information for the CO₂ sensor. - **name** (**Required**, string): The name for the CO₂eq sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **pressure** (**Required**): The information for the Pressure sensor. - **name** (**Required**, string): The name for the Pressure sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **address** (*Optional*, int): Manually specify the I²C address of the sensor. Defaults to ``0x5F``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. See Also -------- - :ref:`sensor-filters` - :doc:`tee501` - :doc:`hte501` - :doc:`dht` - :doc:`dht12` - :apiref:`ee895/ee895.h` - :ghedit:`Edit`