SCD30 CO₂, Temperature and Relative Humidity Sensor =================================================== .. seo:: :description: Instructions for setting up SCD30 CO₂ Temperature and Relative Humidity Sensor :image: scd30.jpg The ``scd30`` sensor platform allows you to use your Sensirion SCD30 CO₂ (`datasheet `__) sensors with ESPHome. The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. .. figure:: images/scd30.jpg :align: center :width: 80.0% .. code-block:: yaml # Example configuration entry sensor: - platform: scd30 co2: name: "Workshop CO2" accuracy_decimals: 1 temperature: name: "Workshop Temperature" accuracy_decimals: 2 humidity: name: "Workshop Humidity" accuracy_decimals: 1 temperature_offset: 1.5 °C address: 0x61 update_interval: 5s Configuration variables: ------------------------ - **co2** (*Optional*): The information for the CO₂ sensor. - **name** (**Required**, string): The name for the CO₂eq sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **temperature** (*Optional*): The information for the Temperature sensor. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **humidity** (*Optional*): The information for the Humidity sensor. - **name** (**Required**, string): The name for the humidity sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **temperature_offset** (*Optional*, float): Temperature and humidity offsets may occur when operating the sensor in end-customer devices. This variable allows the compensation of those effects by setting a temperature offset. - **automatic_self_calibration** (*Optional*, boolean): Whether to enable automatic self calibration (ASC). Defaults to ``true``. - **ambient_pressure_compensation** (*Optional*, int): Enable compensation of measured CO₂ values based on given ambient pressure in mBar. - **altitude_compensation** (*Optional*, int): Enable compensating deviations due to current altitude (in metres). Notice: setting *altitude_compensation* is ignored if *ambient_pressure_compensation* is set. - **address** (*Optional*, int): Manually specify the I²C address of the sensor. Defaults to ``0x61``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. Manual calibration: ------------------------ .. code-block:: yaml # Example on how to implement a UI section in HA for manual calibration. # Note: Please enter first a CO2 value before pressing the button. button: - platform: template name: "SCD30 Force manual calibration" entity_category: "config" on_press: then: - scd30.force_recalibration_with_reference: value: !lambda 'return id(co2_cal).state;' number: - platform: template name: "CO2 calibration value" optimistic: true min_value: 350 max_value: 4500 step: 1 id: co2_cal icon: "mdi:molecule-co2" entity_category: "config" See Also -------- - :ref:`sensor-filters` - :doc:`absolute_humidity` - :doc:`dht` - :doc:`dht12` - :doc:`hdc1080` - :doc:`htu21d` - :apiref:`scd30/scd30.h` - :ghedit:`Edit`