ADE7953 Power Sensor ==================== .. seo:: :description: Instructions for setting up ADE7953 power sensors :image: ade7953.png .. note:: This page is incomplete and could some work. If you want to contribute, please read the :doc:`contributing guide `. This page is missing: - A complete configuration example for the Shelly 2.5 - An image for the front page The ``ade7953`` sensor platform allows you to use ADE7953 single phase energy metering ICs (`datasheet `__) with ESPHome. These are commonly found in **Shelly 2.5** devices. This sensor can measure voltage and has two channels for reading current and active power (A & B). The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. .. code-block:: yaml # Example configuration entry sensor: - platform: ade7953 voltage: name: ADE7953 Voltage current_a: name: ADE7953 Current A current_b: name: ADE7953 Current B active_power_a: name: ADE7953 Active Power A active_power_b: name: ADE7953 Active Power B update_interval: 60s Configuration variables: ------------------------ - **address** (*Optional*, int): Manually specify the i^2c address of the sensor. Defaults to ``0x38``. - **voltage** (*Optional*): Use the voltage value of the sensor in volt. All options from :ref:`Sensor `. - **current_a** (*Optional*): Use the current value of the A channel in amperes. All options from :ref:`Sensor `. - **current_b** (*Optional*): Use the current value of the B channel in amperes. All options from :ref:`Sensor `. - **active_power_a** (*Optional*): Use the power value of the A channel in watts. All options from :ref:`Sensor `. - **active_power_b** (*Optional*): Use the power value of the A channel in watts. All options from :ref:`Sensor `. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. Use with Shelly 2.5 ------------------- The Shelly 2.5 device contains this sensor for power monitoring. An example config for the Shelly 2.5 is given below. There are two oddities with the Shelly 2.5: - First, the A and B channels are mixed up - the chip's A channel is label B on the outside and vice versa. Probably to make the PCB easier to manufacture. - Secondly, due to the first point the active_power values are inverted. This is fixed by using a multiply filter as seen in the config below. Additionally, the device has an ::doc:`NTC temperature sensor `. .. code-block:: yaml i2c: sda: GPIO12 scl: GPIO14 sensor: - platform: ade7953 voltage: name: Shelly Voltage current_a: name: Shelly Current B current_b: name: Shelly Current A active_power_a: name: Shelly Active Power B filters: - multiply: -1 active_power_b: name: Shelly Active Power A filters: - multiply: -1 update_interval: 60s # NTC Temperature - platform: ntc sensor: temp_resistance_reading name: "Shelly Temperature" calibration: b_constant: 3350 reference_resistance: 10kOhm reference_temperature: 298.15K - platform: resistance id: temp_resistance_reading sensor: temp_analog_reading configuration: DOWNSTREAM resistor: 32kOhm - platform: adc id: temp_analog_reading pin: A0 See Also -------- - :ref:`sensor-filters` - :apiref:`ade7953/ade7953.h` - :ghedit:`Edit`