INA226 DC current and power sensor ================================== .. seo:: :description: Instructions for setting up INA226 DC current and power sensors :image: ina226.jpg :keywords: ina226 The ``ina226`` sensor platform allows you to use your INA226 DC Current and Power Sensor (`datasheet `__, `eBay`_) sensors with ESPHome. The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. .. figure:: images/ina226-full.jpg :align: center :width: 50.0% INA226 DC Current and Power Sensor. .. _eBay: https://www.ebay.com/sch/i.html?_nkw=INA226 .. code-block:: yaml # Example configuration entry sensor: - platform: ina226 address: 0x40 shunt_resistance: 0.1 ohm max_current: 3.2A # adc time used for both, Bus Voltage and Shunt Voltage adc_time: 140us adc_averaging: 128 update_interval: 60s current: name: "INA226 Current" power: name: "INA226 Power" bus_voltage: name: "INA226 Bus Voltage" shunt_voltage: name: "INA226 Shunt Voltage" .. code-block:: yaml # Example configuration entry sensor: - platform: ina226 address: 0x40 adc_time: voltage: 140us current: 332us Configuration variables: ------------------------ - **address** (*Optional*, integer): Manually specify the I²C address of the sensor. Defaults to ``0x40``. - **shunt_resistance** (*Optional*, float): The value of the shunt resistor on the board for current calculation. Defaults to ``0.1 ohm``. - **max_current** (*Optional*, float): The maximum current you are expecting. ESPHome will use this to configure the sensor optimally. Defaults to ``3.2A``. - **adc_time** (*Optional*, :ref:`config-time` or both of the following nested options): The time in microseconds to perform a single ADC conversion. Defaults to ``1100us``. Valid values are ``140us``, ``204us``, ``332us``, ``588us``, ``1100us``, ``2116us``, ``4156us``, ``8244us``. - **voltage** (**Required**, :ref:`config-time`) ADC conversion time for Bus Voltage - **current** (**Required**, :ref:`config-time`) ADC conversion time for Shunt Voltage (Current measurement) - **adc_averaging** (*Optional*, integer): Selects ADC sample averaging count. Defaults to ``4``. Valid values are ``1``, ``4``, ``16``, ``64``, ``128``, ``256``, ``512``, ``1024``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. Sensors ------- The component offers four sensors. You can configure all or any subset of them. Each configured sensor is reported separately on each update_interval. The ``name`` option is required for each sensor configured. All other options from :ref:`Sensor `. - **current** (*Optional*): Calculated current output, Amperes. - **power** (*Optional*): Calculated power output, Watts. - **bus_voltage** (*Optional*): Bus voltage output (voltage of the high side contact), Volts. - **shunt_voltage** (*Optional*): Shunt voltage (voltage across the shunt resistor) value of the sensor, Volts. See Also -------- - :ref:`sensor-filters` - :doc:`ina219` - :doc:`ina3221` - :apiref:`ina226/ina226.h` - `INA226 Arduino Library `__ - :ghedit:`Edit`