SM300D2 7-in-1 Air Quality Sensor ================================= .. seo:: :description: Instructions for setting up SM300D2 sensor to work with ESPHome :image: sm300d2-full.jpg :keywords: sm300d2 The ``sm300d2`` sensor platform allows you to use the SM300D2 7-in-1 Air Quality Sensor with ESPHome. .. figure:: images/sm300d2-full.jpg :align: center :width: 50.0% SM300D2 7-in-1 Air Quality Sensor. .. figure:: images/sm300d2-ui.png :align: center :width: 50.0% The SM300D2 sensor supports connections via UART or RS485. This platform only supports UART-connections. Make sure you have a :ref:`UART bus ` in your configuration with the ``rx_pin`` connected to the TX pin of the sensor. The sensor does not support receiving data, so the ``tx_pin`` does not need to be connected. The sensor expects the baud rate to be set at 9600. .. code-block:: yaml # Example configuration entry uart: rx_pin: D0 tx_pin: D1 baud_rate: 9600 sensor: - platform: sm300d2 co2: name: "SM300D2 CO2 Value" formaldehyde: name: "SM300D2 Formaldehyde Value" tvoc: name: "SM300D2 TVOC Value" pm_2_5: name: "SM300D2 PM2.5 Value" pm_10_0: name: "SM300D2 PM10 Value" temperature: name: "SM300D2 Temperature Value" humidity: name: "SM300D2 Humidity Value" update_interval: 60s Configuration variables: ------------------------ - **co2** (**Required**): The CO₂ data from the sensor in parts per million (ppm). - **name** (**Required**, string): The name of the CO₂ sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **formaldehyde** (**Required**): The formaldehyde data of the sensor in micrograms per cubic meter air (µg/m³). - **name** (**Required**, string): The name of the formaldehyde sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **tvoc** (**Required**): The total volatile organic compounds (TVOC) data of the sensor in micrograms per cubic meter air (µg/m³). - **name** (**Required**, string): The name of the TVOC sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **pm_2_5** (**Required**): The PM2.5 data of the sensor in micrograms per cubic meter air (µg/m³). - **name** (**Required**, string): The name of the PM2.5 sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **pm_10_0** (**Required**): The PM10 data of the sensor in micrograms per cubic meter air (µg/m³). - **name** (**Required**, string): The name of the PM10 sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **temperature** (**Required**): The temperature data of the sensor in degrees celsius (°C). - **name** (**Required**, string): The name of the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **humidity** (**Required**): The humidity data of the sensor in percent relative humidity (%). - **name** (**Required**, string): The name of the humidity sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor `. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. - **uart_id** (*Optional*, :ref:`config-id`): Manually specify the ID of the :ref:`UART Component ` if you want to use multiple UART buses. - **id** (*Optional*, :ref:`config-id`): Manually specify the ID used for actions. .. figure:: images/sm300d2-pins.jpg :align: center :width: 80.0% Pins on the SM300D2. UART RX is not in use. .. note:: ``5V`` should be connected to power supply (supported voltage is 4.8 V to 5.2 V), ``GD`` to ``GND`` pin See Also -------- - :ref:`sensor-filters` - :apiref:`sm300d2/sm300d2.h` - :ghedit:`Edit`