DHT Temperature+Humidity Sensor =============================== The DHT Temperature+Humidity sensor allows you to use your DHT11 (`datasheet `__, `adafruit `__), DHT22 (`datasheet `__, `adafruit `__), AM2302 (`datasheet `__, `adafruit `__) and RHT03 (`datashet `__, `sparkfun `__) sensors with esphomelib. .. figure:: images/dht-full.jpg :align: center :width: 50.0% DHT22 Temperature & Humidity Sensor. .. _Adafruit: https://www.adafruit.com/product/385 The DHT22 and DHT11 require external pull up resistors on the data line. To do this, solder a resistor with *about* 4.7kΩ (anything in the range from 1kΩ to 10kΩ probably works fine, but if you're having issues try the 4.7kΩ recommended by the manufacturer) between ``DATA`` and ``3.3V``. .. figure:: images/temperature-humidity.png :align: center :width: 80.0% .. code:: yaml # Example configuration entry sensor: - platform: dht pin: D2 temperature: name: "Living Room Temperature" humidity: name: "Living Room Humidity" update_interval: 15s Configuration variables: ------------------------ - **pin** (**Required**, :ref:`config-pin`): The pin where the DHT bus is connected. - **temperature** (**Required**): The information for the temperature sensor. - **name** (**Required**, string): The name for the temperature sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor ` and :ref:`MQTT Component `. - **humidity** (**Required**): The information for the humidity sensor - **name** (**Required**, string): The name for the humidity sensor. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - All other options from :ref:`Sensor ` and :ref:`MQTT Component `. - **model** (*Optional*, int): Manually specify the DHT model, can be one of ``AUTO_DETECT``, ``DHT11``, ``DHT22``, ``AM2302``, ``RHT03`` and helps with some connection issues. Defaults to ``AUTO_DETECT``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``15s``. See :ref:`sensor-default_filter`. .. note:: If you're seeing lots of invalid temperature/humidity warnings in the logs, try manually setting the DHT model with the ``model:`` configuration variable. Other problems could be wrong pull-up resistor values on the DATA pin or too long cables. See Also -------- - :ref:`sensor-filters` - :doc:`dht12` - :doc:`hdc1080` - :doc:`htu21d` - :doc:`sht3xd` - :doc:`API Reference ` - `Arduino DHTLib `__ - `Edit this page on GitHub `__