uFire Isolated EC sensor ======================== .. seo:: :description: Instructions for setting up uFire Isolated EC sensor in esphome :image: ufire_ec.png :keywords: ufire ec sensor temperature esphome The ``ufire_ec`` sensor platform allows you to use your uFire Isolated EC sensor with ESPHome. The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. It requires also to have a temperature sensor in the liquid tank; this can be on the same board or an external sensor linked to the uFire EC configuration. .. figure:: images/ufire_ec.png :align: center :width: 100.0% .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ec id: ufire_ec_board temperature: id: temperature_liquit name: Temperature ec: name: EC Configuration variables: ------------------------ - **address** (*Optional*, int): Specify the I²C address of the sensor. Defaults to ``0x3C``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - **temperature_sensor** (*Optional*, :ref:`config-id`): Set the ID of the temperature sensor. Only needed if the onboard temperature sensor is not used. - **ec** (*Optional*, :ref:`Sensor `): Set the EC sensor configuration. All options from :ref:`Sensor `. - **temperature** (*Optional*, :ref:`Sensor `): Set the onboard temperature sensor configuration. All options from :ref:`Sensor `. - **temperature_compensation** (*Optional*, float): Set the temperature compensation for the EC sensor. Defaults to ``21.0``. - **temperature_coefficient** (*Optional*, float): Set the temperature coefficient for the EC sensor. Defaults to ``0.019``. .. _sensor-ufire_ec-calibrate_probe_action: ``ufire_ec.calibrate_probe`` Action ----------------------------------- The EC probe have to be calibrated. For this you need know the EC reference value and temperature of the calibration solution. .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ec id: ufire_ec_board # ... # in some trigger on_...: - sensor.ufire_ec_board.calibrate_probe: id: ufire_ec_board solution: 0.146 temperature: !lambda "return id(temperature_liquit).state;" Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the ufire EC sensor. - **solution** (**Required**, float): Solution reference EC value. - **temperature** (**Required**, float): Solution current temperature. .. _sensor-ufire_ec-reset_action: ``ufire_ec.reset`` Action ------------------------- Reset the current calibration on the sensor. .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ec id: ufire_ec_board # ... # in some trigger on_...: - sensor.ufire_ec_board.reset: id: ufire_ec_board Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the ufire EC sensor. See Also -------- - :ref:`sensor-filters` - :apiref:`ufire_ec/ufire_ec.h` - :ghedit:`Edit`