uFire ISE pH sensor =================== .. seo:: :description: Instructions for setting up uFire ISE pH sensor in esphome :image: ufire_ise.png :keywords: ufire ph sensor temperature esphome The ``ufire_ise`` sensor platform allows you to use your uFire ISE pH sensor with ESPHome. The :ref:`I²C Bus ` is required to be set up in your configuration for this sensor to work. It required also to have an temperature sensor in the liquit tank; this can be on the same board or external sensor linked to the uFire ISE pH configuration. .. figure:: images/ufire_ise.png :align: center :width: 100.0% .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ise id: ufire_ise_board temperature: id: temperature_liquit name: Temperature ph: name: pH Configuration variables: ------------------------ - **address** (*Optional*, int): Specify the I²C address of the sensor. Defaults to ``0x3f``. - **update_interval** (*Optional*, :ref:`config-time`): The interval to check the sensor. Defaults to ``60s``. - **id** (*Optional*, :ref:`config-id`): Set the ID of this sensor for use in lambdas. - **temperature_sensor** (*Optional*, :ref:`config-id`): Set the ID of the temperature sensor. Only needed if the onboard temperature sensor is not used. - **ph** (*Optional*, :ref:`Sensor `): Set the pH sensor configuration. All options from :ref:`Sensor `. - **temperature** (*Optional*, :ref:`Sensor `): Set the onboard temperature sensor configuration. All options from :ref:`Sensor `. Can't be used together with ``temperature_sensor``. .. _sensor-ufire_ise-calibrate_probe_high_action: ``ufire_ise.calibrate_probe_high`` Action ----------------------------------------- The pH probe have to be calibrated. For this you need know the pH reference value and temperature of the calibration high solution. .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ise id: ufire_ise_board # ... # in some trigger on_...: - sensor.ufire_ise_board.calibrate_probe_high: id: ufire_ise_board solution: 7.0 temperature: !lambda "return id(temperature_liquit).state;" Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the ufire pH sensor. - **solution** (**Required**, float): Solution reference pH value. .. _sensor-ufire_ise-calibrate_probe_low_action: ``ufire_ise.calibrate_probe_low`` Action ---------------------------------------- The pH probe have to be calibrated. For this you need know the pH reference value and temperature of the calibration low solution. .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ise id: ufire_ise_board # ... # in some trigger on_...: - sensor.ufire_ise_board.calibrate_probe_low: id: ufire_ise_board solution: 4.0 temperature: !lambda "return id(temperature_liquit).state;" Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the ufire pH sensor. - **solution** (**Required**, float): Solution reference pH value. .. _sensor-ufire_ise-reset_action: ``ufire_ise.reset`` Action -------------------------- Reset the current calibration on the sensor. .. code-block:: yaml # Example configuration entry sensor: - platform: ufire_ise id: ufire_ise_board # ... # in some trigger on_...: - sensor.ufire_ise_board.reset: id: ufire_ise_board Configuration options: - **id** (**Required**, :ref:`config-id`): The ID of the ufire pH sensor. See Also -------- - :ref:`sensor-filters` - :apiref:`ufire_ise/ufire_ise.h` - :ghedit:`Edit`